Ning Song, Sara L Hungerford, Sumita Barua, Katherine L Kearney, Kavitha Muthiah, Christopher S Hayward, David W M Muller, Audrey I Adji
{"title":"The Right Ventricular-Arterial Compliance Index: A Novel Hemodynamic Marker to Predict Right Heart Failure Following Left Ventricular Assist Device.","authors":"Ning Song, Sara L Hungerford, Sumita Barua, Katherine L Kearney, Kavitha Muthiah, Christopher S Hayward, David W M Muller, Audrey I Adji","doi":"10.1097/MAT.0000000000002280","DOIUrl":null,"url":null,"abstract":"<p><p>The development of right heart failure (RHF) in patients with advanced heart failure following left ventricular assist device (LVAD) implantation remains difficult to predict. We proposed a novel composite hemodynamic index-the right ventricular-arterial compliance index (RVACi), derived from pulmonary artery pulse pressure (PAPP), ejection time (ET), heart rate (HR), and cardiac output (CO), with and expressed as mm Hg·s/L. We then conducted a retrospective, single-center analysis comparing the predictive value of RVACi for the development of RHF or unplanned right ventricular (RV) mechanical circulatory support following LVAD implantation against existing hemodynamic indices. One hundred patients were enrolled after screening 232 patients over a 10 year period, with 74 patients having complete hemodynamic data for RVACi calculation. There was good correlation between pulmonary arterial capacitance (R² = 0.48) and pulmonary vascular resistance (R² = 0.63) with RVACi, but not RV stroke work index or pulmonary artery pulsatility index. Reduced baseline RVACi (52 ± 23 vs. 92 ± 55 mm Hg·s/L; p = 0.02) was the strongest hemodynamic predictor of unplanned RV mechanical circulatory support requirement in patients following LVAD insertion. Composite pulsatile hemodynamic indices including RVACi may provide additional insight over existing hemodynamic indices for the prediction of RHF and need for RV mechanical circulatory support.</p>","PeriodicalId":8844,"journal":{"name":"ASAIO Journal","volume":" ","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ASAIO Journal","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1097/MAT.0000000000002280","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The development of right heart failure (RHF) in patients with advanced heart failure following left ventricular assist device (LVAD) implantation remains difficult to predict. We proposed a novel composite hemodynamic index-the right ventricular-arterial compliance index (RVACi), derived from pulmonary artery pulse pressure (PAPP), ejection time (ET), heart rate (HR), and cardiac output (CO), with and expressed as mm Hg·s/L. We then conducted a retrospective, single-center analysis comparing the predictive value of RVACi for the development of RHF or unplanned right ventricular (RV) mechanical circulatory support following LVAD implantation against existing hemodynamic indices. One hundred patients were enrolled after screening 232 patients over a 10 year period, with 74 patients having complete hemodynamic data for RVACi calculation. There was good correlation between pulmonary arterial capacitance (R² = 0.48) and pulmonary vascular resistance (R² = 0.63) with RVACi, but not RV stroke work index or pulmonary artery pulsatility index. Reduced baseline RVACi (52 ± 23 vs. 92 ± 55 mm Hg·s/L; p = 0.02) was the strongest hemodynamic predictor of unplanned RV mechanical circulatory support requirement in patients following LVAD insertion. Composite pulsatile hemodynamic indices including RVACi may provide additional insight over existing hemodynamic indices for the prediction of RHF and need for RV mechanical circulatory support.
期刊介绍:
ASAIO Journal is in the forefront of artificial organ research and development. On the cutting edge of innovative technology, it features peer-reviewed articles of the highest quality that describe research, development, the most recent advances in the design of artificial organ devices and findings from initial testing. Bimonthly, the ASAIO Journal features state-of-the-art investigations, laboratory and clinical trials, and discussions and opinions from experts around the world.
The official publication of the American Society for Artificial Internal Organs.