Patent ductus arteriosus closure in small infants weighing less than 1500 g using KA micro plug: steps and tips.

IF 0.9 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS Cardiology in the Young Pub Date : 2024-10-04 DOI:10.1017/S1047951124025629
Bassel Mohammad Nijres, Moeez Hassan, Jimmy Winsdor, Adrianne Rahde Bischoff, Patrick J McNamara, Osamah Aldoss
{"title":"Patent ductus arteriosus closure in small infants weighing less than 1500 g using KA micro plug: steps and tips.","authors":"Bassel Mohammad Nijres, Moeez Hassan, Jimmy Winsdor, Adrianne Rahde Bischoff, Patrick J McNamara, Osamah Aldoss","doi":"10.1017/S1047951124025629","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transcatheter patent ductus arteriosus closure in premature infants is gaining attention with rapidly growing experience. The KA micro plug device poses many favourable features for ductus arteriosus closure in premature infants. The study aimed to describe the technique and outcomes of a KA micro plug in closing the ductus arteriosus in premature infants weighing less than 1500 g.</p><p><strong>Methods: </strong>This is a single-centre retrospective study in premature infants with patent ductus arteriosus weighing less than 1500 g who underwent off-label use of a KA micro plug at the Stead Family Children's Hospital from February 2022 to December 2023.</p><p><strong>Results: </strong>Eighteen premature infants weighing less than 1500 g underwent attempted transcatheter ductus arteriosus closure using a KA micro plug device. Median weight, age, and corrected gestational age at the procedure were 943 g (682-1225), 26 days (9-79), and 28.5 weeks (25.6-32), respectively. The procedure was successful with complete closure achieved in all patients. No major haemodynamic instabilities were encountered. No catheterization-related complications were encountered. On a median follow-up of 10.9 months (0.1-19), all patients are alive with the device in a good position without residual shunt or abnormal findings.</p><p><strong>Conclusion: </strong>KA micro plug device for patent ductus arteriosus in infants weighing less than 1500 g is feasible, safe, and effective. We recommend that manufacturers of devices used to close the ductus arteriosus in small infants enhance both the devices and their delivery systems to simplify the procedure and mitigate the risk of haemodynamic instability.</p>","PeriodicalId":9435,"journal":{"name":"Cardiology in the Young","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology in the Young","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1017/S1047951124025629","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Transcatheter patent ductus arteriosus closure in premature infants is gaining attention with rapidly growing experience. The KA micro plug device poses many favourable features for ductus arteriosus closure in premature infants. The study aimed to describe the technique and outcomes of a KA micro plug in closing the ductus arteriosus in premature infants weighing less than 1500 g.

Methods: This is a single-centre retrospective study in premature infants with patent ductus arteriosus weighing less than 1500 g who underwent off-label use of a KA micro plug at the Stead Family Children's Hospital from February 2022 to December 2023.

Results: Eighteen premature infants weighing less than 1500 g underwent attempted transcatheter ductus arteriosus closure using a KA micro plug device. Median weight, age, and corrected gestational age at the procedure were 943 g (682-1225), 26 days (9-79), and 28.5 weeks (25.6-32), respectively. The procedure was successful with complete closure achieved in all patients. No major haemodynamic instabilities were encountered. No catheterization-related complications were encountered. On a median follow-up of 10.9 months (0.1-19), all patients are alive with the device in a good position without residual shunt or abnormal findings.

Conclusion: KA micro plug device for patent ductus arteriosus in infants weighing less than 1500 g is feasible, safe, and effective. We recommend that manufacturers of devices used to close the ductus arteriosus in small infants enhance both the devices and their delivery systems to simplify the procedure and mitigate the risk of haemodynamic instability.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在体重小于 1500 克的小婴儿中使用 KA 微型插头关闭动脉导管未闭:步骤和技巧。
背景:早产儿经导管动脉导管闭合术正受到越来越多的关注,其经验也在迅速增加。KA 微堵装置在早产儿动脉导管闭合术中具有许多有利的特点。本研究旨在描述 KA 微型塞在体重小于 1500 克的早产儿中闭合动脉导管的技术和结果:这是一项单中心回顾性研究,研究对象是2022年2月至2023年12月期间在施泰德家庭儿童医院接受标签外使用KA微型塞的体重不足1500克的动脉导管未闭早产儿:18名体重小于1500克的早产儿尝试使用KA微塞装置进行经导管动脉导管闭合术。手术时的中位体重、年龄和矫正胎龄分别为 943 克(682-1225)、26 天(9-79)和 28.5 周(25.6-32)。手术非常成功,所有患者都实现了完全闭合。没有出现严重的血流动力学不稳定。没有出现导管相关并发症。中位随访时间为 10.9 个月(0.1-19 个月),所有患者均存活,装置位置良好,无残余分流或异常发现:结论:在体重小于 1500 克的婴儿中使用 KA 微堵装置治疗动脉导管未闭是可行、安全和有效的。我们建议用于关闭小婴儿动脉导管的设备制造商改进设备及其输送系统,以简化手术过程并降低血流动力学不稳定的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Cardiology in the Young
Cardiology in the Young 医学-小儿科
CiteScore
1.70
自引率
10.00%
发文量
715
审稿时长
4-8 weeks
期刊介绍: Cardiology in the Young is devoted to cardiovascular issues affecting the young, and the older patient suffering the sequels of congenital heart disease, or other cardiac diseases acquired in childhood. The journal serves the interests of all professionals concerned with these topics. By design, the journal is international and multidisciplinary in its approach, and members of the editorial board take an active role in the its mission, helping to make it the essential journal in paediatric cardiology. All aspects of paediatric cardiology are covered within the journal. The content includes original articles, brief reports, editorials, reviews, and papers devoted to continuing professional development.
期刊最新文献
Assessment of the frequency and risk factors of gastrointestinal bleeding after cardiopulmonary bypass in paediatric cases. Usefulness of percutaneous transluminal coronary balloon angioplasty for coronary artery stenosis after surgery for CHD. A familial case of aortic dilatation with p.Tyr470Cys in TGFBR2 in which the phenotype included only vascular lesions. Executive function deficits in congenital heart surgical patients: prevalence and timing of presentation. Hospital variation in post-operative cardiac extracorporeal membrane oxygenation use and relationship to post-operative mortality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1