{"title":"CMUT for ultrafast passive cavitation detection during ultrasound-induced blood-brain barrier disruption: proof of concept study.","authors":"Corentin Cornu, Laurène Jourdain, Flavien Barcella, Laurent Colin, Zoé Edon, Ambre Dauba, Erwan Selingue, Jean-Luc Gennisson, Benoit Larrat, Dominique Certon, Anthony Novell","doi":"10.1088/1361-6560/ad8334","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective.</i>Cavitation dose monitoring plays a key role in ultrasound drug delivery to the brain. The use of capacitive micromachined ultrasonic transducer (CMUT) technology has a great potential for passive cavitation detection (PCD).<i>Approach.</i>Here, a circular (diameter 7 mm) CMUT centered at 5 MHz was designed to be inserted into a therapeutic transducer (1.5 MHz) used for ultrasound-induced blood-brain barrier (BBB) disruption on mice. CMUT-based real-time cavitation detection was performed during the ultrasound procedure (50<i>μ</i>l intravenous injection of SonoVue microbubbles, frequency 1.5 MHz, PNP 480 kPa, duty Cycle 10%, PRF 10 Hz, duration 60 s). BBB disruption were confirmed by contrast-enhanced 7T-MRI.<i>Main results.</i>The CMUT device has a fractional bandwidth of 140%, almost twice a conventional piezocomposite PCD transducer. As expected, the CMUT device was able to detect the occurrence of harmonic, subharmonic and ultraharmonic frequencies as well as the increase of broadband signal indicating inertial cavitation in a wide frequency range (from 0.75 to 6 MHz). Signal-to-noise ratio was high enough (>40 dB) to perform ultrafast monitoring and follow the subtle intrapulse variations of frequency components at a rate of 10 kHz.<i>Significance</i>. This first<i>in vivo</i>proof of concept demonstrates the interest of CMUT for PCD and encourages us to develop devices for PCD in larger animals by integrating an amplifier directly to the CMUT front-end to considerably increase the signal-to-noise ratio.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":" ","pages":""},"PeriodicalIF":3.3000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/ad8334","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.Cavitation dose monitoring plays a key role in ultrasound drug delivery to the brain. The use of capacitive micromachined ultrasonic transducer (CMUT) technology has a great potential for passive cavitation detection (PCD).Approach.Here, a circular (diameter 7 mm) CMUT centered at 5 MHz was designed to be inserted into a therapeutic transducer (1.5 MHz) used for ultrasound-induced blood-brain barrier (BBB) disruption on mice. CMUT-based real-time cavitation detection was performed during the ultrasound procedure (50μl intravenous injection of SonoVue microbubbles, frequency 1.5 MHz, PNP 480 kPa, duty Cycle 10%, PRF 10 Hz, duration 60 s). BBB disruption were confirmed by contrast-enhanced 7T-MRI.Main results.The CMUT device has a fractional bandwidth of 140%, almost twice a conventional piezocomposite PCD transducer. As expected, the CMUT device was able to detect the occurrence of harmonic, subharmonic and ultraharmonic frequencies as well as the increase of broadband signal indicating inertial cavitation in a wide frequency range (from 0.75 to 6 MHz). Signal-to-noise ratio was high enough (>40 dB) to perform ultrafast monitoring and follow the subtle intrapulse variations of frequency components at a rate of 10 kHz.Significance. This firstin vivoproof of concept demonstrates the interest of CMUT for PCD and encourages us to develop devices for PCD in larger animals by integrating an amplifier directly to the CMUT front-end to considerably increase the signal-to-noise ratio.
期刊介绍:
The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry