Multipoint pacing is associated with improved prognosis and cardiac resynchronization therapy response: MORE-CRT MPP randomized study secondary analyses.
{"title":"Multipoint pacing is associated with improved prognosis and cardiac resynchronization therapy response: MORE-CRT MPP randomized study secondary analyses.","authors":"Calò Leonardo, De Ruvo Ermenegildo, Kolb Christof, Janmohamed Amir, Marques Pedro, Defaye Pascal, Marquie Christelle, Piot Olivier, Grammatico Andrea, Lee Kwangdeok, Lin Wenjiao, Burri Haran, Sperzel Johannes, Thibault Bernard, Rinaldi Christopher, Leclercq Christophe","doi":"10.1093/europace/euae259","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Cardiac resynchronization therapy (CRT) via biventricular (BIV) pacing is indicated in patients with heart failure (HF), reduced ejection fraction, and prolonged QRS duration. Quadripolar leads and multipoint pacing (MPP) allow multiple left ventricle (LV) sites pacing. We aimed to assess the clinical benefit of MPP in patients who do not respond to standard BIV pacing.</p><p><strong>Methods and results: </strong>Overall, 3724 patients were treated with standard BIV pacing. After 6 months, 1639 patients were considered as CRT non-responders (echo-measured relative reduction in LV end-systolic volume (LVESV) < 15%) and randomized to MPP or BIV. We analysed 593 randomized patients (291 MPP, 302 BIV), who had BIV pacing >97% of the time before randomization and complete 12 months of clinical and echocardiographic data. The endpoint composed of freedom from cardiac death and HF hospitalizations and by LVESV relative reduction ≥15% between randomization and 12 months occurred more frequently in MPP [96/291 (33.0%)] vs. BIV [71/302 (23.5%), P = 0.0103], which was also confirmed at multivariate analysis (hazard ratio = 1.55, 95% confidence interval = 1.02-2.34, P = 0.0402 vs. BIV). HF hospitalizations occurred less frequently in MPP [14/291 (4.81%)] vs. BIV [29/302 (9.60%), incidence rate ratio = 50%, P = 0.0245]. Selecting patients with a large (>30 ms) dispersion of interventricular electrical delay among the four LV lead dipoles, reverse remodelling was more frequent in MPP [18/51 (35.3%)] vs. BIV [11/62 (17.7%), P = 0.0335].</p><p><strong>Conclusion: </strong>In patients who do not respond to standard CRT despite the high BIV pacing percentage, MPP is associated with lower occurrence of HF hospitalizations and higher probability of reverse LV remodelling compared with BIV pacing.</p>","PeriodicalId":11981,"journal":{"name":"Europace","volume":" ","pages":""},"PeriodicalIF":7.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11572720/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Europace","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/europace/euae259","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Aims: Cardiac resynchronization therapy (CRT) via biventricular (BIV) pacing is indicated in patients with heart failure (HF), reduced ejection fraction, and prolonged QRS duration. Quadripolar leads and multipoint pacing (MPP) allow multiple left ventricle (LV) sites pacing. We aimed to assess the clinical benefit of MPP in patients who do not respond to standard BIV pacing.
Methods and results: Overall, 3724 patients were treated with standard BIV pacing. After 6 months, 1639 patients were considered as CRT non-responders (echo-measured relative reduction in LV end-systolic volume (LVESV) < 15%) and randomized to MPP or BIV. We analysed 593 randomized patients (291 MPP, 302 BIV), who had BIV pacing >97% of the time before randomization and complete 12 months of clinical and echocardiographic data. The endpoint composed of freedom from cardiac death and HF hospitalizations and by LVESV relative reduction ≥15% between randomization and 12 months occurred more frequently in MPP [96/291 (33.0%)] vs. BIV [71/302 (23.5%), P = 0.0103], which was also confirmed at multivariate analysis (hazard ratio = 1.55, 95% confidence interval = 1.02-2.34, P = 0.0402 vs. BIV). HF hospitalizations occurred less frequently in MPP [14/291 (4.81%)] vs. BIV [29/302 (9.60%), incidence rate ratio = 50%, P = 0.0245]. Selecting patients with a large (>30 ms) dispersion of interventricular electrical delay among the four LV lead dipoles, reverse remodelling was more frequent in MPP [18/51 (35.3%)] vs. BIV [11/62 (17.7%), P = 0.0335].
Conclusion: In patients who do not respond to standard CRT despite the high BIV pacing percentage, MPP is associated with lower occurrence of HF hospitalizations and higher probability of reverse LV remodelling compared with BIV pacing.
期刊介绍:
EP - Europace - European Journal of Pacing, Arrhythmias and Cardiac Electrophysiology of the European Heart Rhythm Association of the European Society of Cardiology. The journal aims to provide an avenue of communication of top quality European and international original scientific work and reviews in the fields of Arrhythmias, Pacing and Cellular Electrophysiology. The Journal offers the reader a collection of contemporary original peer-reviewed papers, invited papers and editorial comments together with book reviews and correspondence.