Multipoint pacing is associated with improved prognosis and cardiac resynchronization therapy response: MORE-CRT MPP randomized study secondary analyses.

IF 7.9 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Europace Pub Date : 2024-11-01 DOI:10.1093/europace/euae259
Calò Leonardo, De Ruvo Ermenegildo, Kolb Christof, Janmohamed Amir, Marques Pedro, Defaye Pascal, Marquie Christelle, Piot Olivier, Grammatico Andrea, Lee Kwangdeok, Lin Wenjiao, Burri Haran, Sperzel Johannes, Thibault Bernard, Rinaldi Christopher, Leclercq Christophe
{"title":"Multipoint pacing is associated with improved prognosis and cardiac resynchronization therapy response: MORE-CRT MPP randomized study secondary analyses.","authors":"Calò Leonardo, De Ruvo Ermenegildo, Kolb Christof, Janmohamed Amir, Marques Pedro, Defaye Pascal, Marquie Christelle, Piot Olivier, Grammatico Andrea, Lee Kwangdeok, Lin Wenjiao, Burri Haran, Sperzel Johannes, Thibault Bernard, Rinaldi Christopher, Leclercq Christophe","doi":"10.1093/europace/euae259","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Cardiac resynchronization therapy (CRT) via biventricular (BIV) pacing is indicated in patients with heart failure (HF), reduced ejection fraction, and prolonged QRS duration. Quadripolar leads and multipoint pacing (MPP) allow multiple left ventricle (LV) sites pacing. We aimed to assess the clinical benefit of MPP in patients who do not respond to standard BIV pacing.</p><p><strong>Methods and results: </strong>Overall, 3724 patients were treated with standard BIV pacing. After 6 months, 1639 patients were considered as CRT non-responders (echo-measured relative reduction in LV end-systolic volume (LVESV) < 15%) and randomized to MPP or BIV. We analysed 593 randomized patients (291 MPP, 302 BIV), who had BIV pacing >97% of the time before randomization and complete 12 months of clinical and echocardiographic data. The endpoint composed of freedom from cardiac death and HF hospitalizations and by LVESV relative reduction ≥15% between randomization and 12 months occurred more frequently in MPP [96/291 (33.0%)] vs. BIV [71/302 (23.5%), P = 0.0103], which was also confirmed at multivariate analysis (hazard ratio = 1.55, 95% confidence interval = 1.02-2.34, P = 0.0402 vs. BIV). HF hospitalizations occurred less frequently in MPP [14/291 (4.81%)] vs. BIV [29/302 (9.60%), incidence rate ratio = 50%, P = 0.0245]. Selecting patients with a large (>30 ms) dispersion of interventricular electrical delay among the four LV lead dipoles, reverse remodelling was more frequent in MPP [18/51 (35.3%)] vs. BIV [11/62 (17.7%), P = 0.0335].</p><p><strong>Conclusion: </strong>In patients who do not respond to standard CRT despite the high BIV pacing percentage, MPP is associated with lower occurrence of HF hospitalizations and higher probability of reverse LV remodelling compared with BIV pacing.</p>","PeriodicalId":11981,"journal":{"name":"Europace","volume":" ","pages":""},"PeriodicalIF":7.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11572720/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Europace","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/europace/euae259","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: Cardiac resynchronization therapy (CRT) via biventricular (BIV) pacing is indicated in patients with heart failure (HF), reduced ejection fraction, and prolonged QRS duration. Quadripolar leads and multipoint pacing (MPP) allow multiple left ventricle (LV) sites pacing. We aimed to assess the clinical benefit of MPP in patients who do not respond to standard BIV pacing.

Methods and results: Overall, 3724 patients were treated with standard BIV pacing. After 6 months, 1639 patients were considered as CRT non-responders (echo-measured relative reduction in LV end-systolic volume (LVESV) < 15%) and randomized to MPP or BIV. We analysed 593 randomized patients (291 MPP, 302 BIV), who had BIV pacing >97% of the time before randomization and complete 12 months of clinical and echocardiographic data. The endpoint composed of freedom from cardiac death and HF hospitalizations and by LVESV relative reduction ≥15% between randomization and 12 months occurred more frequently in MPP [96/291 (33.0%)] vs. BIV [71/302 (23.5%), P = 0.0103], which was also confirmed at multivariate analysis (hazard ratio = 1.55, 95% confidence interval = 1.02-2.34, P = 0.0402 vs. BIV). HF hospitalizations occurred less frequently in MPP [14/291 (4.81%)] vs. BIV [29/302 (9.60%), incidence rate ratio = 50%, P = 0.0245]. Selecting patients with a large (>30 ms) dispersion of interventricular electrical delay among the four LV lead dipoles, reverse remodelling was more frequent in MPP [18/51 (35.3%)] vs. BIV [11/62 (17.7%), P = 0.0335].

Conclusion: In patients who do not respond to standard CRT despite the high BIV pacing percentage, MPP is associated with lower occurrence of HF hospitalizations and higher probability of reverse LV remodelling compared with BIV pacing.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
多点起搏与预后改善和心脏再同步治疗反应相关。MORE-CRT MPP 随机研究二次分析。
背景和目的:通过双心室(BIV)起搏进行心脏再同步化治疗(CRT)适用于心力衰竭(HF)、射血分数降低和 QRS 间期延长的患者。四极导联和多点起搏(MPP)允许多个左心室(LV)部位起搏。我们旨在评估 MPP 对标准 BIV 起搏无效患者的临床益处:共有 3724 名患者接受了标准 BIV 起搏治疗。6个月后,1639名患者被视为CRT无应答者(回声测量左心室收缩末期容积(LVESV)相对缩小):我们分析了 593 名随机患者(291 名 MPP,302 名 BIV),他们在随机化前进行 BIV 起搏的时间大于 97%,并获得了完整的 12 个月临床和超声心动图数据。终点由心源性死亡和心房颤动住院自由度以及随机化至 12 个月期间 LVESV 相对下降≥15% 组成,MPP(96/291 (33.0%))与 BIV(71/302 (23.5%),p = 0.0103)的发生率更高,多变量分析也证实了这一点(危险比 = 1.55,95% 置信区间 = 1.02-2.34,p = 0.0402,与 BIV 相比)。MPP(14/291 (4.81%))与BIV(29/302 (9.60%),发病率比=50%,P=0.0245)相比,HF住院发生率较低。选择4个左心室导联偶极之间室间电延迟弥散较大(>30 ms)的患者,MPP(18/51 (35.3%))与BIV(11/62 (17.7%),p = 0.0335)的反向重塑发生率更高:结论:在对标准 CRT 无反应的患者中,尽管 BIV 起搏比例较高,但与 BIV 起搏相比,MPP 与较低的 HF 住院率和较高的左心室反向重塑概率相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Europace
Europace 医学-心血管系统
CiteScore
10.30
自引率
8.20%
发文量
851
审稿时长
3-6 weeks
期刊介绍: EP - Europace - European Journal of Pacing, Arrhythmias and Cardiac Electrophysiology of the European Heart Rhythm Association of the European Society of Cardiology. The journal aims to provide an avenue of communication of top quality European and international original scientific work and reviews in the fields of Arrhythmias, Pacing and Cellular Electrophysiology. The Journal offers the reader a collection of contemporary original peer-reviewed papers, invited papers and editorial comments together with book reviews and correspondence.
期刊最新文献
Familial risk of sinus node dysfunction indicating pacemaker implantation: A nation-wide cohort study. Increased Pacemaker Implantation and Mortality Rates in Relatives of Patients with Early-Onset Sinus Node Dysfunction: Can Genetics Explain All? Electrograms peak frequency analysis for ventricular tachycardia ablations. When technology improves our understanding of the physiology. aTrial arrhythmias in inhEriTed aRrhythmIa Syndromes: results from the TETRIS study. Temperature guided high and very high-power short duration ablation for atrial fibrillation treatment - The peQasus multicentre study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1