Zhou Sha, Tianyi Ling, Wenqi Yang, Haosu Xie, Chunnan Wang and Shuqing Sun
{"title":"Microfluidic synthesis and accurate immobilization of low-density QD-encoded magnetic microbeads for multiplex immunoassay†","authors":"Zhou Sha, Tianyi Ling, Wenqi Yang, Haosu Xie, Chunnan Wang and Shuqing Sun","doi":"10.1039/D4TB01585A","DOIUrl":null,"url":null,"abstract":"<p >Magnetic-fluorescent microbeads have been widely used in the multiplex detection of biological molecules. The traditional method relies on flow cytometry to decode and analyze the microbeads. Alternative strategies that employ immobilized microbeads on a plane and involve fluorescence imaging to analyze the microbeads have been proposed. Among these strategies, an integrated chip that controls magnetic field contribution using nickel powder pillars and captured microbeads has attracted great attention. Despite its unique advantages such as low manufacturing costs, reusability and high capture efficiency, existing research had been limited by the inability to precisely capture a single microbead, and the overlapping of microbeads has made multiplex immunoassays based on this strategy impossible. In this work, low-density microbeads were prepared in a microfluidic chip using IBOMA as the main monomer. The low density of the microbeads made the preparation of an aqueous suspension easier. An integration of nickel patterns, magnets and channels was carried out and demonstrated the capacity of capturing single microbeads precisely. Fluorescence coding further empowered this method with the ability of multiplex immunoassay, which was verified using three types of IgG, and a calibration curve for the detection of anti-human IgG was established using a sandwich immunoassay. These results show the promising potential of this strategy for biomedical detection.</p>","PeriodicalId":83,"journal":{"name":"Journal of Materials Chemistry B","volume":" 43","pages":" 11230-11236"},"PeriodicalIF":6.1000,"publicationDate":"2024-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Materials Chemistry B","FirstCategoryId":"1","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/tb/d4tb01585a","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
Magnetic-fluorescent microbeads have been widely used in the multiplex detection of biological molecules. The traditional method relies on flow cytometry to decode and analyze the microbeads. Alternative strategies that employ immobilized microbeads on a plane and involve fluorescence imaging to analyze the microbeads have been proposed. Among these strategies, an integrated chip that controls magnetic field contribution using nickel powder pillars and captured microbeads has attracted great attention. Despite its unique advantages such as low manufacturing costs, reusability and high capture efficiency, existing research had been limited by the inability to precisely capture a single microbead, and the overlapping of microbeads has made multiplex immunoassays based on this strategy impossible. In this work, low-density microbeads were prepared in a microfluidic chip using IBOMA as the main monomer. The low density of the microbeads made the preparation of an aqueous suspension easier. An integration of nickel patterns, magnets and channels was carried out and demonstrated the capacity of capturing single microbeads precisely. Fluorescence coding further empowered this method with the ability of multiplex immunoassay, which was verified using three types of IgG, and a calibration curve for the detection of anti-human IgG was established using a sandwich immunoassay. These results show the promising potential of this strategy for biomedical detection.
期刊介绍:
Journal of Materials Chemistry A, B & C cover high quality studies across all fields of materials chemistry. The journals focus on those theoretical or experimental studies that report new understanding, applications, properties and synthesis of materials. Journal of Materials Chemistry A, B & C are separated by the intended application of the material studied. Broadly, applications in energy and sustainability are of interest to Journal of Materials Chemistry A, applications in biology and medicine are of interest to Journal of Materials Chemistry B, and applications in optical, magnetic and electronic devices are of interest to Journal of Materials Chemistry C.Journal of Materials Chemistry B is a Transformative Journal and Plan S compliant. Example topic areas within the scope of Journal of Materials Chemistry B are listed below. This list is neither exhaustive nor exclusive:
Antifouling coatings
Biocompatible materials
Bioelectronics
Bioimaging
Biomimetics
Biomineralisation
Bionics
Biosensors
Diagnostics
Drug delivery
Gene delivery
Immunobiology
Nanomedicine
Regenerative medicine & Tissue engineering
Scaffolds
Soft robotics
Stem cells
Therapeutic devices