Heparin does not improve myocardial glucose metabolism suppression in [18 F]FDG PET/CT in patients with low β-hydroxybutyrate level.

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-10-08 DOI:10.1186/s13550-024-01153-y
Suvi Hartikainen, Ville Vepsäläinen, Tiina Laitinen, Marja Hedman, Tomi Laitinen, Tuomo Tompuri
{"title":"Heparin does not improve myocardial glucose metabolism suppression in [18 F]FDG PET/CT in patients with low β-hydroxybutyrate level.","authors":"Suvi Hartikainen, Ville Vepsäläinen, Tiina Laitinen, Marja Hedman, Tomi Laitinen, Tuomo Tompuri","doi":"10.1186/s13550-024-01153-y","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Inadequate myocardial glucose metabolism suppression (GMS) can hamper interpretation of cardiac [<sup>18</sup>F]fluorodeoxyglucose (FDG) positron emission tomography (PET/CT). Use of β-hydroxybutyrate (BHB) measurement before [<sup>18</sup>F]FDG injection has been proposed for predicting adequate GMS. However, limited information is available on BHB measurement in guiding preparations for [<sup>18</sup>F]FDG-PET/CT. The purpose of this study was to evaluate if point-of-care measured BHB is useful in guiding heparin premedication for cardiac [<sup>18</sup>F]FDG-PET/CT.</p><p><strong>Results: </strong>155 patients (82 male) had followed a high-fat, low-carbohydrate diet and fasted for at least twelve hours. For the first 63 patients, BHB was measured, but it was not used to guide premedication. For the subsequent 92 patients, heparin 50 IU/kg was injected intravenously 15-20 min before [<sup>18</sup>F]FDG injection if the BHB level was low (< 0.35 mmol/l). Cardiac [<sup>18</sup>F]FDG uptake pattern was evaluated visually and [<sup>18</sup>F]FDG uptake in the myocardium and blood pool were measured. Median BHB level was 0.4 (range 0.1-5.8) mmol/l. Eighty-eight patients (57%) reached a BHB level higher than 0.35 mmol/l. 112 patients (72%) had adequate GMS. In the high BHB group, 74 patients (84%) had adequate GMS, whereas of those with low BHB, only 38 (57%) had adequate GMS (p < 0.001). In the low BHB group, the prevalence of inadequate GMS was comparable in patients with and without heparin (44% vs. 42%, p = 0.875).</p><p><strong>Conclusions: </strong>While high BHB predicts adequate GMS, unfractionated heparin does not improve GMS in patients with low BHB.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11461714/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13550-024-01153-y","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Inadequate myocardial glucose metabolism suppression (GMS) can hamper interpretation of cardiac [18F]fluorodeoxyglucose (FDG) positron emission tomography (PET/CT). Use of β-hydroxybutyrate (BHB) measurement before [18F]FDG injection has been proposed for predicting adequate GMS. However, limited information is available on BHB measurement in guiding preparations for [18F]FDG-PET/CT. The purpose of this study was to evaluate if point-of-care measured BHB is useful in guiding heparin premedication for cardiac [18F]FDG-PET/CT.

Results: 155 patients (82 male) had followed a high-fat, low-carbohydrate diet and fasted for at least twelve hours. For the first 63 patients, BHB was measured, but it was not used to guide premedication. For the subsequent 92 patients, heparin 50 IU/kg was injected intravenously 15-20 min before [18F]FDG injection if the BHB level was low (< 0.35 mmol/l). Cardiac [18F]FDG uptake pattern was evaluated visually and [18F]FDG uptake in the myocardium and blood pool were measured. Median BHB level was 0.4 (range 0.1-5.8) mmol/l. Eighty-eight patients (57%) reached a BHB level higher than 0.35 mmol/l. 112 patients (72%) had adequate GMS. In the high BHB group, 74 patients (84%) had adequate GMS, whereas of those with low BHB, only 38 (57%) had adequate GMS (p < 0.001). In the low BHB group, the prevalence of inadequate GMS was comparable in patients with and without heparin (44% vs. 42%, p = 0.875).

Conclusions: While high BHB predicts adequate GMS, unfractionated heparin does not improve GMS in patients with low BHB.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
肝素不能改善β-羟丁酸水平低的患者心肌葡萄糖代谢在[18 F]FDG PET/CT中的抑制作用。
背景:心肌葡萄糖代谢抑制(GMS)不足会影响心脏[18F]氟脱氧葡萄糖(FDG)正电子发射断层扫描(PET/CT)的解读。有人建议在注射[18F]FDG 之前测量β-羟丁酸(BHB),以预测是否有足够的 GMS。然而,关于在[18F]FDG-PET/CT 的指导准备中测量 BHB 的信息非常有限。本研究旨在评估护理点测量的 BHB 是否有助于指导心脏[18F]FDG-PET/CT 的肝素预处理:155 名患者(82 名男性)采用高脂肪、低碳水化合物饮食并禁食至少 12 小时。对前 63 名患者进行了 BHB 测量,但并未用于指导预处理。对于随后的 92 名患者,如果 BHB 水平较低,则在注射[18F]FDG 前 15-20 分钟静脉注射肝素 50 IU/kg(用肉眼评估 18F]FDG 摄取模式,并测量心肌和血池的[18F]FDG 摄取)。中位 BHB 水平为 0.4(范围 0.1-5.8)毫摩尔/升。88名患者(57%)的胆碱酯酶水平高于0.35毫摩尔/升。112 名患者(72%)有足够的 GMS。在高 BHB 组中,74 名患者(84%)有足够的 GMS,而在低 BHB 组中,只有 38 名患者(57%)有足够的 GMS(P 结论:在高 BHB 组中,GMS 充足率较低,而在低 BHB 组中,GMS 充足率较高:虽然高胆红素血症可预测适当的 GMS,但对于低胆红素血症患者来说,非分数肝素并不能改善 GMS。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊最新文献
[Corrigendum] Tripartite motif‑containing 11 regulates the proliferation and apoptosis of breast cancer cells. [Retracted] Glutathione peroxidase 2 overexpression promotes malignant progression and cisplatin resistance of KRAS‑mutated lung cancer cells. [Retracted] Stimulation of peroxisome proliferator‑activated receptor γ inhibits estrogen receptor α transcriptional activity in endometrial carcinoma cells. Compression force promotes glioblastoma progression through the Piezo1‑GDF15‑CTLA4 axis. Huaier promotes sensitivity of colorectal cancer to oxaliplatin by inhibiting METTL3 to regulate the Wnt/β‑catenin signaling pathway.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1