Clinical evaluation of a smart wristband for monitoring oxygen saturation, pulse rate, and respiratory rate.

IF 2 3区 医学 Q2 ANESTHESIOLOGY Journal of Clinical Monitoring and Computing Pub Date : 2024-10-10 DOI:10.1007/s10877-024-01229-z
Stefan H J Monnink, Mariska van Vliet, Mathijs J Kuiper, Jan C Constandse, Dieke Hoftijzer, Marjolein Muller, Eelko Ronner
{"title":"Clinical evaluation of a smart wristband for monitoring oxygen saturation, pulse rate, and respiratory rate.","authors":"Stefan H J Monnink, Mariska van Vliet, Mathijs J Kuiper, Jan C Constandse, Dieke Hoftijzer, Marjolein Muller, Eelko Ronner","doi":"10.1007/s10877-024-01229-z","DOIUrl":null,"url":null,"abstract":"<p><p>Recently, photoplethysmography-based vital parameter measurements have increased in popularity. However, clinical evaluation of these measurements is lacking. The objective of this study was to rigorously evaluate the clinical accuracy and reliability of a novel photoplethysmography-based wristband for measuring key vital parameters-oxygen saturation (SpO2), respiratory rate (RR), and pulse rate (PR)-during heart catheterisations. Vital parameters obtained during heart catheterisations by means of a photoplethysmography-based wristband (CardioWatch 287-2, Corsano Health) were compared to reference measurements performed by a Nellcor fingerclip (SpO2, PR) as well as a 5-lead ECG (RR) (QMAPP Haemodynamic Monitoring module, Fysicon B.V.) by means of correlation coefficients and root means squared error (RMSE). Effects of skin colour and arm hair density were additionally evaluated. In total, 945 samples from a total of 100 patients were included in the analysis. The correlation coefficients and RSME obtained for the difference between reference and photoplethysmography-based wristband measurements were r = 0.815 and 1.6% for SpO2, r = 0.976 and 0.9 brpm for RR, and r = 0.995 and 1.3 bpm for PR. Similar results were obtained across all skin colour and arm hair density subcategories. This study shows that photoplethysmography-based SpO2, RR, and PR measurements can be accurate during heart catheterisations. Future investigations are required to evaluate the wristband's performance under dynamic circumstances as well as over an extended time period. Trial registration: www.clinicaltrials.gov, NCT05566886.</p>","PeriodicalId":15513,"journal":{"name":"Journal of Clinical Monitoring and Computing","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Monitoring and Computing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10877-024-01229-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Recently, photoplethysmography-based vital parameter measurements have increased in popularity. However, clinical evaluation of these measurements is lacking. The objective of this study was to rigorously evaluate the clinical accuracy and reliability of a novel photoplethysmography-based wristband for measuring key vital parameters-oxygen saturation (SpO2), respiratory rate (RR), and pulse rate (PR)-during heart catheterisations. Vital parameters obtained during heart catheterisations by means of a photoplethysmography-based wristband (CardioWatch 287-2, Corsano Health) were compared to reference measurements performed by a Nellcor fingerclip (SpO2, PR) as well as a 5-lead ECG (RR) (QMAPP Haemodynamic Monitoring module, Fysicon B.V.) by means of correlation coefficients and root means squared error (RMSE). Effects of skin colour and arm hair density were additionally evaluated. In total, 945 samples from a total of 100 patients were included in the analysis. The correlation coefficients and RSME obtained for the difference between reference and photoplethysmography-based wristband measurements were r = 0.815 and 1.6% for SpO2, r = 0.976 and 0.9 brpm for RR, and r = 0.995 and 1.3 bpm for PR. Similar results were obtained across all skin colour and arm hair density subcategories. This study shows that photoplethysmography-based SpO2, RR, and PR measurements can be accurate during heart catheterisations. Future investigations are required to evaluate the wristband's performance under dynamic circumstances as well as over an extended time period. Trial registration: www.clinicaltrials.gov, NCT05566886.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
对用于监测血氧饱和度、脉搏和呼吸频率的智能腕带进行临床评估。
最近,基于血压计的生命参数测量方法越来越受欢迎。然而,目前还缺乏对这些测量方法的临床评估。本研究的目的是严格评估在心脏导管插入术中测量主要生命参数--氧饱和度(SpO2)、呼吸频率(RR)和脉搏频率(PR)--的新型光感腕带的临床准确性和可靠性。通过相关系数和均方根误差 (RMSE),将在心脏导管插入术中通过光电血压计腕带(CardioWatch 287-2,Corsano Health)获得的生命参数与 Nellcor 指夹(SpO2、PR)以及五导联心电图(RR)(QMAPP 血流动力学监测模块,Fysicon B.V.)进行的参考测量值进行了比较。此外,还评估了肤色和臂毛密度的影响。共有 100 名患者的 945 个样本被纳入分析。参考值和基于光电血压计的腕带测量值之间差异的相关系数和 RSME 分别为:SpO2:r = 0.815 和 1.6%;RR:r = 0.976 和 0.9 bpm;PR:r = 0.995 和 1.3 bpm。所有肤色和臂毛密度子类别都得到了类似的结果。本研究表明,在心脏导管插入术中,基于光敏血压计的 SpO2、RR 和 PR 测量是准确的。未来的研究还需要对腕带在动态环境下和长时间内的性能进行评估。试验注册:www.clinicaltrials.gov,NCT05566886。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.30
自引率
13.60%
发文量
144
审稿时长
6-12 weeks
期刊介绍: The Journal of Clinical Monitoring and Computing is a clinical journal publishing papers related to technology in the fields of anaesthesia, intensive care medicine, emergency medicine, and peri-operative medicine. The journal has links with numerous specialist societies, including editorial board representatives from the European Society for Computing and Technology in Anaesthesia and Intensive Care (ESCTAIC), the Society for Technology in Anesthesia (STA), the Society for Complex Acute Illness (SCAI) and the NAVAt (NAVigating towards your Anaestheisa Targets) group. The journal publishes original papers, narrative and systematic reviews, technological notes, letters to the editor, editorial or commentary papers, and policy statements or guidelines from national or international societies. The journal encourages debate on published papers and technology, including letters commenting on previous publications or technological concerns. The journal occasionally publishes special issues with technological or clinical themes, or reports and abstracts from scientificmeetings. Special issues proposals should be sent to the Editor-in-Chief. Specific details of types of papers, and the clinical and technological content of papers considered within scope can be found in instructions for authors.
期刊最新文献
Automated and reference methods for the calculation of left ventricular outflow tract velocity time integral or ejection fraction by non-cardiologists: a systematic review on the agreement of the two methods. Entropy of difference works similarly to permutation entropy for the assessment of anesthesia and sleep EEG despite the lower computational effort. Noninvasive estimation of PaCO2 from volumetric capnography in animals with injured lungs: an Artificial Intelligence approach. Rapid non-invasive measurement of mitochondrial oxygen tension after microneedle pre-treatment: a feasibility study in human volunteers. Electroencephalogram monitoring during anesthesia and critical care: a guide for the clinician.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1