Effect of Age on Distortion Product Otoacoustic Emissions at Extended High Frequencies.

Nutan Malviya, Palani Saravanan
{"title":"Effect of Age on Distortion Product Otoacoustic Emissions at Extended High Frequencies.","authors":"Nutan Malviya, Palani Saravanan","doi":"10.5152/iao.2024.241484","DOIUrl":null,"url":null,"abstract":"<p><p>The inner ear is most susceptible to the aging effects. Distortion product otoacoustic emissions (DPOAEs) are a good indicator for interpreting the age effects but are usually recorded at up to 8000 Hz frequencies in routine audiologic testing. The present study was designed to assess and compare the DPOAEs at conventional frequencies and at extended high frequencies (EHFs) across different age groups. Extended high-frequency audiometry (9000-16000 Hz) and DPOAEs from 500-16000 Hz were recorded on 80 adult (160 ears) participants (15-55 years) with normal hearing sensitivity. The participants were categorized into 4 groups: group I (15-<25 years), group II (25-<35 years), group III (35-<45 years), and group IV (45-55 years). A statistically significant reduction in EHF thresholds was observed from group III onward. However, the thresholds were comparatively better for group III at frequencies 9000, 10000, and 11500Hz than group IV. No significant difference was observed for EHF DPOAEs in groups I and II (except at 16000 Hz) and III and IV. Distortion product otoacoustic emissions at conventional frequencies in group IV were significantly poorer than the other 3 groups. A weak negative correlation was observed between the DPOAE parameters and EHF thresholds. The effect of age was more pronounced on EHF DPOAEs than EHF thresholds for frequencies 9000, 10000, and 11500 Hz. Distortion product otoacoustic emissions at EHF started deteriorating below the age of 30 years and showed a rapid decline above 35 years. Extended high-frequency DPOAEs can be used as screening tools to assess the function of the basal part of the cochlea.</p>","PeriodicalId":94238,"journal":{"name":"The journal of international advanced otology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11562102/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of international advanced otology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/iao.2024.241484","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The inner ear is most susceptible to the aging effects. Distortion product otoacoustic emissions (DPOAEs) are a good indicator for interpreting the age effects but are usually recorded at up to 8000 Hz frequencies in routine audiologic testing. The present study was designed to assess and compare the DPOAEs at conventional frequencies and at extended high frequencies (EHFs) across different age groups. Extended high-frequency audiometry (9000-16000 Hz) and DPOAEs from 500-16000 Hz were recorded on 80 adult (160 ears) participants (15-55 years) with normal hearing sensitivity. The participants were categorized into 4 groups: group I (15-<25 years), group II (25-<35 years), group III (35-<45 years), and group IV (45-55 years). A statistically significant reduction in EHF thresholds was observed from group III onward. However, the thresholds were comparatively better for group III at frequencies 9000, 10000, and 11500Hz than group IV. No significant difference was observed for EHF DPOAEs in groups I and II (except at 16000 Hz) and III and IV. Distortion product otoacoustic emissions at conventional frequencies in group IV were significantly poorer than the other 3 groups. A weak negative correlation was observed between the DPOAE parameters and EHF thresholds. The effect of age was more pronounced on EHF DPOAEs than EHF thresholds for frequencies 9000, 10000, and 11500 Hz. Distortion product otoacoustic emissions at EHF started deteriorating below the age of 30 years and showed a rapid decline above 35 years. Extended high-frequency DPOAEs can be used as screening tools to assess the function of the basal part of the cochlea.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
年龄对扩展高频失真产物耳声发射的影响
内耳最容易受到老化效应的影响。失真产物耳声发射(DPOAEs)是解释老化效应的良好指标,但在常规听力学测试中通常记录的频率高达 8000 Hz。本研究旨在评估和比较不同年龄组在常规频率和扩展高频(EHF)下的 DPOAEs。本研究记录了 80 名听力正常的成年参与者(160 耳)(15-55 岁)的扩展高频测听(9000-16000 Hz)和 500-16000 Hz 的 DPOAEs。参与者被分为四组:第一组(15-55 岁);第二组(15-55 岁);第三组(15-55 岁);第四组(15-55 岁)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An International Survey of the Diagnosis and Management of Ménière's Disease Amongst Otolaryngology Consultants. Associations of Blood Lipids with the Risk and Prognosis of Sudden Sensorineural Hearing Loss: A Meta-analysis. Auditory Memory and Visual Memory in Typically Developing Children: Modality Dependence/ Independence. Auditory Memory and Visual Memory in Typically Developing Children: Modality Dependence/ Independence. Constant Dizziness Versus Episodic Vertigo in Ménière's Disease: Health-Related Quality of Life, Cognitive Dissonance, and Postural Problems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1