An In-Field Eigenvalue-Based Stability Assessment Method for Low-Frequency Dynamic Interaction Between Voltage Source Converters and the Grid

IF 4.9 2区 工程技术 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC IEEE Journal of Emerging and Selected Topics in Power Electronics Pub Date : 2024-10-10 DOI:10.1109/JESTPE.2024.3477446
Yuguo Li;Hao Yi;Fang Zhuo;Xin Jiang;Deshuo Yu
{"title":"An In-Field Eigenvalue-Based Stability Assessment Method for Low-Frequency Dynamic Interaction Between Voltage Source Converters and the Grid","authors":"Yuguo Li;Hao Yi;Fang Zhuo;Xin Jiang;Deshuo Yu","doi":"10.1109/JESTPE.2024.3477446","DOIUrl":null,"url":null,"abstract":"Voltage-source converters (VSCs) are essential for renewable energy. However, the oscillatory behavior generated by dynamic interaction between VSCs and the grid is a challenging issue due to the interaction’s intricacy and unknown system details. After introducing VSCs into the power system, stability assessment is often wanted. “Perturbation-based impedance measuring + Middle-Brook criterion” is a well-known approach. However, this approach is rarely adopted due to the need for perturbation devices (PDs). So this article proposes a stability assessment method to obtain the system eigenvalue map. This method does not need PDs, so is in-field adaptive. The eigenvalue map is evaluated from closed-loop frequency responses (FRs) by vector fitting (VF), and the FRs are measured by the VSC itself. To support the method theoretically, a modularized model of the VSC-grid system is derived. The model indicates how each closed-loop FR of the VSC(s) reflects all the eigenvalues of the VSC-grid system. Because the transfer zeros of some FRs reduce the observability of some eigenvalues, weighted combination of VF results from multiple FRs is adopted in the proposed method to guarantee the precision. The accuracy of the proposed assessment method and investigation results is verified by both simulations and experiments.","PeriodicalId":13093,"journal":{"name":"IEEE Journal of Emerging and Selected Topics in Power Electronics","volume":"13 1","pages":"542-552"},"PeriodicalIF":4.9000,"publicationDate":"2024-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Journal of Emerging and Selected Topics in Power Electronics","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10713299/","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Voltage-source converters (VSCs) are essential for renewable energy. However, the oscillatory behavior generated by dynamic interaction between VSCs and the grid is a challenging issue due to the interaction’s intricacy and unknown system details. After introducing VSCs into the power system, stability assessment is often wanted. “Perturbation-based impedance measuring + Middle-Brook criterion” is a well-known approach. However, this approach is rarely adopted due to the need for perturbation devices (PDs). So this article proposes a stability assessment method to obtain the system eigenvalue map. This method does not need PDs, so is in-field adaptive. The eigenvalue map is evaluated from closed-loop frequency responses (FRs) by vector fitting (VF), and the FRs are measured by the VSC itself. To support the method theoretically, a modularized model of the VSC-grid system is derived. The model indicates how each closed-loop FR of the VSC(s) reflects all the eigenvalues of the VSC-grid system. Because the transfer zeros of some FRs reduce the observability of some eigenvalues, weighted combination of VF results from multiple FRs is adopted in the proposed method to guarantee the precision. The accuracy of the proposed assessment method and investigation results is verified by both simulations and experiments.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于现场特征值的电压源转换器与电网低频动态交互稳定性评估方法
电压源转换器(VSCs)对于可再生能源是必不可少的。然而,由于相互作用的复杂性和未知的系统细节,VSCs与电网之间动态相互作用产生的振荡行为是一个具有挑战性的问题。在vsc引入电力系统后,往往需要进行稳定性评估。“基于微扰的阻抗测量+ Middle-Brook准则”是一种众所周知的方法。然而,由于需要微扰装置(pd),这种方法很少被采用。为此,本文提出了一种获得系统特征值映射的稳定性评价方法。该方法不需要pd,具有现场自适应能力。通过向量拟合(VF)从闭环频率响应(FRs)计算特征值映射,并由VSC本身测量FRs。为了从理论上支持该方法,推导了VSC-grid系统的模块化模型。该模型表明了VSC(s)的每个闭环FR如何反映VSC-网格系统的所有特征值。由于某些频域信号的传递零降低了某些特征值的可观测性,因此该方法采用多个频域信号的VF结果加权组合来保证精度。仿真和实验验证了所提出的评价方法和调查结果的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
12.50
自引率
9.10%
发文量
547
审稿时长
3 months
期刊介绍: The aim of the journal is to enable the power electronics community to address the emerging and selected topics in power electronics in an agile fashion. It is a forum where multidisciplinary and discriminating technologies and applications are discussed by and for both practitioners and researchers on timely topics in power electronics from components to systems.
期刊最新文献
Seamless Switching Control Utilizing Zero-Voltage Vector Intervals for PMSM Winding Reconfiguration Disturbance Rejection Enhanced Two-Degree-of-Freedom Current Controller using Active Damping Function for PMSM System A Fault Diagnosis and Fault-Tolerant Control Method for Open-Circuit Fault of Excitation Winding Converter in DSEM Drive System A Robust Fault Diagnosis Method for Rotating Bearing of Inverter-fed Machine Using PWM Switching Oscillations A Single-Phase Integrated On-board Charger for Plug-in Dual-Motor EVs
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1