Yong-Jun Lee, Hsien-Hao Chang, Joon-Ryul Lim, Tae-Hwan Yoon, Yong-Min Chun
{"title":"Humeral stem alignment of curved short stem in reverse shoulder arthroplasty: Varus/Valgus alignment is not a determinant for clinical outcomes.","authors":"Yong-Jun Lee, Hsien-Hao Chang, Joon-Ryul Lim, Tae-Hwan Yoon, Yong-Min Chun","doi":"10.1016/j.jse.2024.08.022","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to investigate the influence of curved short stem alignment within the proximal humerus on the clinical outcomes of reverse shoulder arthroplasty. We hypothesized that the varus/valgus alignment would yield clinical outcomes comparable to those of a neutral alignment.</p><p><strong>Methods: </strong>We retrospectively reviewed 167 patients who underwent reverse shoulder arthroplasty using the Aequalis Ascend Flex implant between January 2017 and December 2021. The study categorized the patients into three groups based on the angle difference between the humeral axis and the stem axis: neutral group (GN, defined as within ±5 degrees), valgus group (GL), and varus group (GR). Functional outcomes were assessed using the visual analog scale pain score, subjective shoulder value, American Shoulder and Elbow Surgeons score, University of California Los Angeles shoulder score, and active range of motion. Routine radiographic evaluations were also conducted to assess the filling ratio and bone resorption.</p><p><strong>Results: </strong>Among 138 patients, 89 were in the GN group, 37 (27%) in the GL group, and 12 (9%) in the GR group. The average degree of varus alignment was 6 (range from 5 to 7 degrees), while the average degree of valgus alignment was -7 (range from -8 to -5 degrees). According to our findings, the clinical outcomes did not exhibit significant differences between the three groups. Furthermore, the radiological outcomes showed no significant differences among the three groups.</p><p><strong>Conclusions: </strong>Compared to neutral alignment, varus or valgus alignment of the humeral stem in reverse shoulder arthroplasty using a curved short stem does not significantly affect clinical outcomes.</p>","PeriodicalId":50051,"journal":{"name":"Journal of Shoulder and Elbow Surgery","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Shoulder and Elbow Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jse.2024.08.022","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study aimed to investigate the influence of curved short stem alignment within the proximal humerus on the clinical outcomes of reverse shoulder arthroplasty. We hypothesized that the varus/valgus alignment would yield clinical outcomes comparable to those of a neutral alignment.
Methods: We retrospectively reviewed 167 patients who underwent reverse shoulder arthroplasty using the Aequalis Ascend Flex implant between January 2017 and December 2021. The study categorized the patients into three groups based on the angle difference between the humeral axis and the stem axis: neutral group (GN, defined as within ±5 degrees), valgus group (GL), and varus group (GR). Functional outcomes were assessed using the visual analog scale pain score, subjective shoulder value, American Shoulder and Elbow Surgeons score, University of California Los Angeles shoulder score, and active range of motion. Routine radiographic evaluations were also conducted to assess the filling ratio and bone resorption.
Results: Among 138 patients, 89 were in the GN group, 37 (27%) in the GL group, and 12 (9%) in the GR group. The average degree of varus alignment was 6 (range from 5 to 7 degrees), while the average degree of valgus alignment was -7 (range from -8 to -5 degrees). According to our findings, the clinical outcomes did not exhibit significant differences between the three groups. Furthermore, the radiological outcomes showed no significant differences among the three groups.
Conclusions: Compared to neutral alignment, varus or valgus alignment of the humeral stem in reverse shoulder arthroplasty using a curved short stem does not significantly affect clinical outcomes.
期刊介绍:
The official publication for eight leading specialty organizations, this authoritative journal is the only publication to focus exclusively on medical, surgical, and physical techniques for treating injury/disease of the upper extremity, including the shoulder girdle, arm, and elbow. Clinically oriented and peer-reviewed, the Journal provides an international forum for the exchange of information on new techniques, instruments, and materials. Journal of Shoulder and Elbow Surgery features vivid photos, professional illustrations, and explicit diagrams that demonstrate surgical approaches and depict implant devices. Topics covered include fractures, dislocations, diseases and injuries of the rotator cuff, imaging techniques, arthritis, arthroscopy, arthroplasty, and rehabilitation.