Use of a Xenon Gamma Spectrometer for Dosimetry in Boron–Neutron Capture Therapy

IF 0.3 4区 物理与天体物理 Q4 PHYSICS, NUCLEAR Physics of Atomic Nuclei Pub Date : 2024-10-07 DOI:10.1134/S1063778824700601
I. F. Khimmatov, S. E. Ulin
{"title":"Use of a Xenon Gamma Spectrometer for Dosimetry in Boron–Neutron Capture Therapy","authors":"I. F. Khimmatov,&nbsp;S. E. Ulin","doi":"10.1134/S1063778824700601","DOIUrl":null,"url":null,"abstract":"<p>One of the main problems associated with the implementation of neutron capture therapy in clinical practice, requiring a solution, is the determination of absorbed dose. The only method that directly allows measuring the absorbed does is gamma spectrometry based on the detection of gamma rays with an energy of 478 keV. This article considers the possibility of using a xenon gamma spectrometer, which has high radiation resistance to neutron fluxes. The GEANT4 software package was used to study the neutron capture therapy process and conduct corresponding calculations.</p>","PeriodicalId":728,"journal":{"name":"Physics of Atomic Nuclei","volume":"87 5","pages":"620 - 624"},"PeriodicalIF":0.3000,"publicationDate":"2024-10-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics of Atomic Nuclei","FirstCategoryId":"101","ListUrlMain":"https://link.springer.com/article/10.1134/S1063778824700601","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSICS, NUCLEAR","Score":null,"Total":0}
引用次数: 0

Abstract

One of the main problems associated with the implementation of neutron capture therapy in clinical practice, requiring a solution, is the determination of absorbed dose. The only method that directly allows measuring the absorbed does is gamma spectrometry based on the detection of gamma rays with an energy of 478 keV. This article considers the possibility of using a xenon gamma spectrometer, which has high radiation resistance to neutron fluxes. The GEANT4 software package was used to study the neutron capture therapy process and conduct corresponding calculations.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在硼-中子俘获疗法中使用氙伽马能谱仪进行剂量测定
在临床实践中实施中子俘获疗法需要解决的主要问题之一是吸收剂量的测定。唯一能直接测量吸收剂量的方法是伽马能谱仪,它以检测能量为 478 千伏的伽马射线为基础。本文考虑了使用氙伽马能谱仪的可能性,这种仪器对中子通量具有很强的抗辐射能力。使用 GEANT4 软件包研究了中子俘获治疗过程并进行了相应的计算。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Physics of Atomic Nuclei
Physics of Atomic Nuclei 物理-物理:核物理
CiteScore
0.60
自引率
25.00%
发文量
56
审稿时长
3-6 weeks
期刊介绍: Physics of Atomic Nuclei is a journal that covers experimental and theoretical studies of nuclear physics: nuclear structure, spectra, and properties; radiation, fission, and nuclear reactions induced by photons, leptons, hadrons, and nuclei; fundamental interactions and symmetries; hadrons (with light, strange, charm, and bottom quarks); particle collisions at high and superhigh energies; gauge and unified quantum field theories, quark models, supersymmetry and supergravity, astrophysics and cosmology.
期刊最新文献
Cross Section of the Process \({e^{+}e^{-}\to n\bar{n}}\) near the Threshold Investigation of High-Energy Neutrinos at the Large Hadron Collider Rare Decays of \({D_{s}}\) Mesons to Three Charged Leptons and a Neutrino within the Standard Model Modeling of Local Strong Parity Non-Conservation Effects in Relativistic Heavy-Ion Collisions Photoneutron Reaction Cross Sections for \({}^{{90}}\)Zr in Different Experiments
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1