{"title":"Effects of Distance, Temperature, and Relative Humidity on the Irradiance of Ultraviolet-C Germicidal Lamp: A Quantitative Study","authors":"Yu Wu,&nbsp;Yuqi Wang,&nbsp;Jinyang Liu,&nbsp;Xinyang Xu,&nbsp;Youwen Song,&nbsp;Xiaorong Zhang,&nbsp;Lili Jiang,&nbsp;Peng Chen","doi":"10.1155/2024/1951792","DOIUrl":null,"url":null,"abstract":"<p>Ultraviolet germicidal irradiation (UVGI) as an engineering control against pathogenic microbes necessitates a clear understanding of operational parameters and environmental effects on inactivation rates. Here, we investigated the variation laws of ultraviolet-C (UV-C) irradiance under the influence of distance, ambient conditions of temperature, and relative humidity (RH) in a dark chamber using 30-W low-pressure mercury lamps, and all data were analyzed with curve fitting methods. UV-C irradiances in each plane were measured as the distance adjusting between 0.5 and 1.2 m, and a threshold of 70 <i>μ</i>W/cm<sup>2</sup> was utilized to calculate the effective irradiation area. For the temperature and RH, UV-C irradiances were measured at 1 m perpendicular from the lamp axis at the lamp midpoint, with the ambient temperature increasing from 15.5°C to 40°C and RH adjusting from 10% to 97%. Results showed that the UV-C irradiance and effective irradiation area exhibited a notable decrease as the distance increased, both corresponded to polynomial 2nd order fits. The UV-C lamps operate at maximum efficiency at 20°C. Temperature above or below the optimum value will decrease UV output, especially when the ambient temperature exceeds 38°C and the irradiance decreases by 16% compared to the observed maximum. However, the impact of RH on radiant power is negligible with the UV-C irradiance maintaining an overall steady state (84–91 <i>μ</i>W/cm<sup>2</sup>) in the 10%–97% RH range. The use of the measurement and modeling techniques demonstrated in this study may help understand various ambient conditions that influence the irradiance of UV-C and improve reliability and working performance of UVGI systems through better design.</p>","PeriodicalId":13529,"journal":{"name":"Indoor air","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/1951792","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indoor air","FirstCategoryId":"93","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2024/1951792","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Ultraviolet germicidal irradiation (UVGI) as an engineering control against pathogenic microbes necessitates a clear understanding of operational parameters and environmental effects on inactivation rates. Here, we investigated the variation laws of ultraviolet-C (UV-C) irradiance under the influence of distance, ambient conditions of temperature, and relative humidity (RH) in a dark chamber using 30-W low-pressure mercury lamps, and all data were analyzed with curve fitting methods. UV-C irradiances in each plane were measured as the distance adjusting between 0.5 and 1.2 m, and a threshold of 70 μW/cm2 was utilized to calculate the effective irradiation area. For the temperature and RH, UV-C irradiances were measured at 1 m perpendicular from the lamp axis at the lamp midpoint, with the ambient temperature increasing from 15.5°C to 40°C and RH adjusting from 10% to 97%. Results showed that the UV-C irradiance and effective irradiation area exhibited a notable decrease as the distance increased, both corresponded to polynomial 2nd order fits. The UV-C lamps operate at maximum efficiency at 20°C. Temperature above or below the optimum value will decrease UV output, especially when the ambient temperature exceeds 38°C and the irradiance decreases by 16% compared to the observed maximum. However, the impact of RH on radiant power is negligible with the UV-C irradiance maintaining an overall steady state (84–91 μW/cm2) in the 10%–97% RH range. The use of the measurement and modeling techniques demonstrated in this study may help understand various ambient conditions that influence the irradiance of UV-C and improve reliability and working performance of UVGI systems through better design.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
距离、温度和相对湿度对紫外线 C 型杀菌灯辐照度的影响:定量研究
紫外线杀菌照射(UVGI)作为一种针对病原微生物的工程控制手段,需要清楚地了解操作参数和环境对灭活率的影响。在此,我们使用 30 瓦低压汞灯在暗室中研究了紫外线-C(UV-C)辐照度在距离、环境温度和相对湿度(RH)条件影响下的变化规律,并对所有数据进行了曲线拟合分析。测量每个平面上的紫外线-C 辐照度时,距离在 0.5 至 1.2 米之间进行调整,并利用 70 μW/cm2 的阈值来计算有效辐照面积。对于温度和相对湿度,在环境温度从 15.5°C 升至 40°C、相对湿度从 10% 升至 97% 的情况下,在灯管中点垂直于灯管轴线 1 米处测量紫外线-C 辐照度。结果显示,紫外线-C 辐照度和有效辐照面积随着距离的增加而明显减小,两者都符合多项式二阶拟合。紫外线-C 灯在 20 摄氏度时工作效率最高。温度高于或低于最佳值都会降低紫外线输出,特别是当环境温度超过 38°C 时,辐照度会比观测到的最大值降低 16%。不过,相对湿度对辐射功率的影响可以忽略不计,在相对湿度为 10%-97% 的范围内,紫外线-C 辐照度总体保持稳定状态(84-91 μW/cm2)。使用本研究中展示的测量和建模技术,有助于了解影响紫外线-C 辐照度的各种环境条件,并通过更好的设计提高紫外光源照射系统的可靠性和工作性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Indoor air
Indoor air 环境科学-工程:环境
CiteScore
10.80
自引率
10.30%
发文量
175
审稿时长
3 months
期刊介绍: The quality of the environment within buildings is a topic of major importance for public health. Indoor Air provides a location for reporting original research results in the broad area defined by the indoor environment of non-industrial buildings. An international journal with multidisciplinary content, Indoor Air publishes papers reflecting the broad categories of interest in this field: health effects; thermal comfort; monitoring and modelling; source characterization; ventilation and other environmental control techniques. The research results present the basic information to allow designers, building owners, and operators to provide a healthy and comfortable environment for building occupants, as well as giving medical practitioners information on how to deal with illnesses related to the indoor environment.
期刊最新文献
Objective and Subjective Indoor Air Quality and Thermal Comfort Indices: Characterization of Mediterranean Climate Archetypal Schools After the COVID-19 Pandemic Indoor Air Quality: Predicting and Comparing Protective Behaviors in Germany and Portugal Holographic Air-Quality Monitor (HAM) Indoor Exchange Rates and Penetration From Outdoors in an Instrumented Terraced House (Townhouse) Using Gas Tracers: Implications for Particles and Gases Indoors A Respiratory Simulator for the Study of Pathogen Transmission in Indoor Environments
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1