3D melt blowing of Elastollan thermoplastic polyurethane for tissue engineering applications: A pilot study

IF 1.9 Q3 ENGINEERING, MANUFACTURING Manufacturing Letters Pub Date : 2024-10-01 DOI:10.1016/j.mfglet.2024.09.043
Advay Pawar , Bruce Anderson , Behnam Pourdeyhimi , Amy L. McNulty , Matthew Fisher , Rohan Shirwaiker
{"title":"3D melt blowing of Elastollan thermoplastic polyurethane for tissue engineering applications: A pilot study","authors":"Advay Pawar ,&nbsp;Bruce Anderson ,&nbsp;Behnam Pourdeyhimi ,&nbsp;Amy L. McNulty ,&nbsp;Matthew Fisher ,&nbsp;Rohan Shirwaiker","doi":"10.1016/j.mfglet.2024.09.043","DOIUrl":null,"url":null,"abstract":"<div><div>Scaffolds, in addition to being biocompatible, should possess structural and mechanical properties similar to the natural tissues they intend to replace. Many tissue engineering applications require porous 3D scaffolds characterized by unique microfibrous organization and mechanical anisotropy. Manufacturing process principles and process parameter-biomaterial interactions ultimately govern the properties that can be achieved in the scaffold. In this study, we investigate a recently developed nonwoven scaffold fabrication process, 3D melt blowing (3DMB), for processing Elastollan®, a thermoplastic polyurethane with basic mechanical properties suitable for musculoskeletal tissue engineering. The range of feasible processing parameters was screened and the effects of two sets of critical process parameters (fiber deposition offset and surface velocity of the collector) that produced contrasting scaffold morphologies were assessed. Results showed that scaffolds of Group B that were fabricated at the higher fiber deposition offset (90 %) and higher surface velocity of the collector (6 × 10<sup>5</sup> mm/min) possessed significantly smaller fiber diameter and higher porosity and degree of fiber alignment along the principal direction of collector rotation during 3DMB (all p &lt; 0.05) compared to Group A scaffolds (fabricated at 50 % offset and 1 × 10<sup>5</sup> mm/min surface velocity). Although both groups possessed similar tensile stiffness, the elongation at failure was significantly different (p &lt; 0.0001). The higher elongation at failure of Group B correlated with the higher degree of fiber alignment in these scaffolds. In contrast, the more isotropic fibrous organization of Group A contributed to their higher compressive stiffness (p = 0.004). The introduction of NaOH treatment to improve hydrophilicity of the scaffolds resulted in a significant reduction of tensile stiffness of Group A (p &lt; 0.05) but not Group B. This treatment did not significantly affect the elongation at failure or compressive stiffness of both groups. With NaOH-treatment, both groups demonstrated good biocompatibility when seeded with fibroblast cells over 14 days. This study confirms the ability to fabricate via 3DMB, biocompatible, micro-fibrous, Elastollan scaffolds relevant for musculoskeletal tissue engineering.</div></div>","PeriodicalId":38186,"journal":{"name":"Manufacturing Letters","volume":"41 ","pages":"Pages 357-363"},"PeriodicalIF":1.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Manufacturing Letters","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2213846324001056","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, MANUFACTURING","Score":null,"Total":0}
引用次数: 0

Abstract

Scaffolds, in addition to being biocompatible, should possess structural and mechanical properties similar to the natural tissues they intend to replace. Many tissue engineering applications require porous 3D scaffolds characterized by unique microfibrous organization and mechanical anisotropy. Manufacturing process principles and process parameter-biomaterial interactions ultimately govern the properties that can be achieved in the scaffold. In this study, we investigate a recently developed nonwoven scaffold fabrication process, 3D melt blowing (3DMB), for processing Elastollan®, a thermoplastic polyurethane with basic mechanical properties suitable for musculoskeletal tissue engineering. The range of feasible processing parameters was screened and the effects of two sets of critical process parameters (fiber deposition offset and surface velocity of the collector) that produced contrasting scaffold morphologies were assessed. Results showed that scaffolds of Group B that were fabricated at the higher fiber deposition offset (90 %) and higher surface velocity of the collector (6 × 105 mm/min) possessed significantly smaller fiber diameter and higher porosity and degree of fiber alignment along the principal direction of collector rotation during 3DMB (all p < 0.05) compared to Group A scaffolds (fabricated at 50 % offset and 1 × 105 mm/min surface velocity). Although both groups possessed similar tensile stiffness, the elongation at failure was significantly different (p < 0.0001). The higher elongation at failure of Group B correlated with the higher degree of fiber alignment in these scaffolds. In contrast, the more isotropic fibrous organization of Group A contributed to their higher compressive stiffness (p = 0.004). The introduction of NaOH treatment to improve hydrophilicity of the scaffolds resulted in a significant reduction of tensile stiffness of Group A (p < 0.05) but not Group B. This treatment did not significantly affect the elongation at failure or compressive stiffness of both groups. With NaOH-treatment, both groups demonstrated good biocompatibility when seeded with fibroblast cells over 14 days. This study confirms the ability to fabricate via 3DMB, biocompatible, micro-fibrous, Elastollan scaffolds relevant for musculoskeletal tissue engineering.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于组织工程应用的 Elastollan 热塑性聚氨酯三维熔体吹塑:试点研究
支架除了具有生物相容性外,还应该具有与要替代的天然组织相似的结构和机械特性。许多组织工程应用要求多孔三维支架具有独特的微纤维组织和机械各向异性。制造工艺原理以及工艺参数与生物材料之间的相互作用最终决定了支架所能达到的性能。在本研究中,我们研究了最近开发的一种无纺布支架制造工艺--三维熔体吹塑(3DMB),用于加工 Elastollan®,这是一种热塑性聚氨酯,具有适合肌肉骨骼组织工程的基本机械性能。对可行的加工参数范围进行了筛选,并评估了两组关键加工参数(纤维沉积偏移量和收集器表面速度)对产生截然不同的支架形态的影响。结果显示,与 A 组支架(以 50% 的偏移量和 1 × 105 mm/min 的表面速度制造)相比,以较高的纤维沉积偏移量(90%)和较高的收集器表面速度(6 × 105 mm/min)制造的 B 组支架具有明显较小的纤维直径、较高的孔隙率以及在 3DMB 期间沿收集器主要旋转方向的纤维排列程度(所有 p < 0.05)。虽然两组具有相似的拉伸刚度,但破坏时的伸长率却有显著差异(p < 0.0001)。B 组较高的破坏伸长率与这些支架中较高的纤维排列程度有关。相比之下,A 组的纤维组织各向同性更强,因此抗压刚度更高(p = 0.004)。为提高支架的亲水性而引入 NaOH 处理会显著降低 A 组的拉伸刚度(p < 0.05),但不会降低 B 组的拉伸刚度。经 NaOH 处理后,两组在 14 天内播种成纤维细胞时均表现出良好的生物相容性。这项研究证实了通过 3DMB 制造生物相容性微纤维 Elastollan 支架的能力,这种支架适用于肌肉骨骼组织工程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Manufacturing Letters
Manufacturing Letters Engineering-Industrial and Manufacturing Engineering
CiteScore
4.20
自引率
5.10%
发文量
192
审稿时长
60 days
期刊最新文献
Applicability of circularity protocols to extend the lifetime of a thermoplastic pultrusion line: A case study Feasibility study of using friction stir extruded recycled aluminum rods for welding and additive manufacturing Scalable and efficient fabrication of surface microstructures using a small wheeled robot with a vibration-cutting tool Influence of parameter variation and interlayer temperature control in wall angle, curvature and measurement methodology of ER70S-6 parts obtained by WAAM Hard and wear resistant AISI304 stainless steel clad layer deposited on mild steel substrate by TIG cladding
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1