Australian radiographers’ digital era practice in selecting the image receptor angle for female body habitus for the mediolateral oblique view of the breast
{"title":"Australian radiographers’ digital era practice in selecting the image receptor angle for female body habitus for the mediolateral oblique view of the breast","authors":"R. Pape","doi":"10.1016/j.radi.2024.10.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Correct alignment of the image receptor (IR) in mammography for the mediolateral oblique (MLO) view of the breast is fundamental to enable the maximum inclusion of breast tissue. This study aims to assess Australian radiographers' knowledge and digital era practice in selecting the IR angle for female body habitus in the MLO view of the breast.</div></div><div><h3>Methods</h3><div>An online survey was distributed to all members of the Australian Society of Medical Imaging and Radiation Therapy (ASMIRT) through their electronic newsletter and via direct email to radiographers holding the Certificate of Mammographic Practice (CMP). Descriptive analysis was undertaken, and a Pearson's chi-squared test of independence was used to compare associations between academic qualification and IR selection data. A value of p < 0.05 was deemed statistically significant.</div></div><div><h3>Results</h3><div>A total of 107 valid surveys were returned; 67.3 % reported using the posterior lateral margin to select the IR angle. For linear body habitus, 44.9 % reported using 50°; for all other body habitus, participants most commonly used 45° (59.1 %); 85.1 % used a range of angles between 40 and 55°; 16.8 % recognised the link between correct IR angle selection and breast tissue inclusion.</div></div><div><h3>Conclusion</h3><div>The range of angles used in practice has reduced in the digital era; the frequency of the use of 45° across all body habitus may reflect tube angle movement automation. Few radiographers recognised the important link between correct selection of IR angle and breast tissue inclusion on the image.</div></div><div><h3>Implications for practice</h3><div>Understanding of the link between IR angle selection and image quality enhances current practice in the digital era to maximise the inclusion of breast tissue and minimise the potential of missed breast cancer.</div></div>","PeriodicalId":47416,"journal":{"name":"Radiography","volume":"30 6","pages":"Pages 1612-1621"},"PeriodicalIF":2.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiography","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1078817424002980","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Correct alignment of the image receptor (IR) in mammography for the mediolateral oblique (MLO) view of the breast is fundamental to enable the maximum inclusion of breast tissue. This study aims to assess Australian radiographers' knowledge and digital era practice in selecting the IR angle for female body habitus in the MLO view of the breast.
Methods
An online survey was distributed to all members of the Australian Society of Medical Imaging and Radiation Therapy (ASMIRT) through their electronic newsletter and via direct email to radiographers holding the Certificate of Mammographic Practice (CMP). Descriptive analysis was undertaken, and a Pearson's chi-squared test of independence was used to compare associations between academic qualification and IR selection data. A value of p < 0.05 was deemed statistically significant.
Results
A total of 107 valid surveys were returned; 67.3 % reported using the posterior lateral margin to select the IR angle. For linear body habitus, 44.9 % reported using 50°; for all other body habitus, participants most commonly used 45° (59.1 %); 85.1 % used a range of angles between 40 and 55°; 16.8 % recognised the link between correct IR angle selection and breast tissue inclusion.
Conclusion
The range of angles used in practice has reduced in the digital era; the frequency of the use of 45° across all body habitus may reflect tube angle movement automation. Few radiographers recognised the important link between correct selection of IR angle and breast tissue inclusion on the image.
Implications for practice
Understanding of the link between IR angle selection and image quality enhances current practice in the digital era to maximise the inclusion of breast tissue and minimise the potential of missed breast cancer.
RadiographyRADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.70
自引率
34.60%
发文量
169
审稿时长
63 days
期刊介绍:
Radiography is an International, English language, peer-reviewed journal of diagnostic imaging and radiation therapy. Radiography is the official professional journal of the College of Radiographers and is published quarterly. Radiography aims to publish the highest quality material, both clinical and scientific, on all aspects of diagnostic imaging and radiation therapy and oncology.