The Clinical Impact of Urinalysis Screened by Automated Microscopy Compared to Reference Manual Analysis.

IF 4.3 3区 医学 Q1 UROLOGY & NEPHROLOGY American Journal of Nephrology Pub Date : 2024-10-16 DOI:10.1159/000541561
Priscila Aparecida Correa Freitas, Yasmini Dandara Silva da Silva, José Antonio Tesser Poloni, Francisco José Veríssimo Veronese, Luiz Felipe Santos Goncalves
{"title":"The Clinical Impact of Urinalysis Screened by Automated Microscopy Compared to Reference Manual Analysis.","authors":"Priscila Aparecida Correa Freitas, Yasmini Dandara Silva da Silva, José Antonio Tesser Poloni, Francisco José Veríssimo Veronese, Luiz Felipe Santos Goncalves","doi":"10.1159/000541561","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Clinical laboratories have replaced conventional manual urine microscopy with automated urinalysis; however, concerns persist regarding its validity in detecting specific elements of urinary sediment crucial for evaluating kidney diseases. This study aimed to assess the accuracy of urinary sediment analysis performed by a large hospital laboratory compared to a standardized microscopic review, focusing on patients both with and without kidney disease.</p><p><strong>Methods: </strong>Urine samples were randomly selected from routine laboratory specimens at a university hospital. Laboratory analysis was performed using LabUmat 2 and Urised 3 PRO equipment (Abbott Diagnostics). In the automated analysis for sediment examination, technicians have the option to reclassify urinary sediment elements as necessary and, if warranted, conduct manual microscopic evaluations to validate findings. The laboratory's analysis was compared with a \"reference\" analysis, which was double-blinded and conducted by two experienced technicians using bright-field and phase-contrast microscopy.</p><p><strong>Results: </strong>503 samples were selected, with 52.3% originating from nephrology outpatient clinic patients. Overall agreement between the laboratory results and the reference analysis was 42.1%. The sensitivity (SN) of the laboratory examination for detecting pathological casts, lipiduria, and renal tubular epithelial cells was low (<50%), while specificity (SP) was high (>98%). However, for hyaline casts (SN: 50.4%; SP: 80.9%) and dysmorphic red blood cells (SN: 62.3%; SP: 96.2%), accuracy was intermediate. Performance was better for hematuria (SN: 86.1%; SP: 82.3%; intraclass correlation coefficient [ICC]: 0.703; R: 0.828) and leukocyturia (SN: 84.9%; SP: 95.1%; ICC: 0.807; R: 0.861). In patients with kidney disease (N = 248) and in samples manually reviewed by the laboratory (N = 115), accuracy for each urinary element was comparable to the overall sample findings. However, when assessing the ability to identify elements suggestive of nephropathy, only samples manually reviewed by the laboratory showed statistically similar results to those obtained by the reference analysis (p = 0.503, McNemar's test).</p><p><strong>Conclusion: </strong>Employing automated urinalysis seems to be accurate for detecting hematuria and leukocyturia, as well as for screening patients without kidney diseases. However, clinical laboratories attending complex patients should employ personalized strategies to help decide when to perform manual review, thus avoiding misleading urinalysis results.</p>","PeriodicalId":7570,"journal":{"name":"American Journal of Nephrology","volume":" ","pages":"1-9"},"PeriodicalIF":4.3000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Nephrology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000541561","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Clinical laboratories have replaced conventional manual urine microscopy with automated urinalysis; however, concerns persist regarding its validity in detecting specific elements of urinary sediment crucial for evaluating kidney diseases. This study aimed to assess the accuracy of urinary sediment analysis performed by a large hospital laboratory compared to a standardized microscopic review, focusing on patients both with and without kidney disease.

Methods: Urine samples were randomly selected from routine laboratory specimens at a university hospital. Laboratory analysis was performed using LabUmat 2 and Urised 3 PRO equipment (Abbott Diagnostics). In the automated analysis for sediment examination, technicians have the option to reclassify urinary sediment elements as necessary and, if warranted, conduct manual microscopic evaluations to validate findings. The laboratory's analysis was compared with a "reference" analysis, which was double-blinded and conducted by two experienced technicians using bright-field and phase-contrast microscopy.

Results: 503 samples were selected, with 52.3% originating from nephrology outpatient clinic patients. Overall agreement between the laboratory results and the reference analysis was 42.1%. The sensitivity (SN) of the laboratory examination for detecting pathological casts, lipiduria, and renal tubular epithelial cells was low (<50%), while specificity (SP) was high (>98%). However, for hyaline casts (SN: 50.4%; SP: 80.9%) and dysmorphic red blood cells (SN: 62.3%; SP: 96.2%), accuracy was intermediate. Performance was better for hematuria (SN: 86.1%; SP: 82.3%; intraclass correlation coefficient [ICC]: 0.703; R: 0.828) and leukocyturia (SN: 84.9%; SP: 95.1%; ICC: 0.807; R: 0.861). In patients with kidney disease (N = 248) and in samples manually reviewed by the laboratory (N = 115), accuracy for each urinary element was comparable to the overall sample findings. However, when assessing the ability to identify elements suggestive of nephropathy, only samples manually reviewed by the laboratory showed statistically similar results to those obtained by the reference analysis (p = 0.503, McNemar's test).

Conclusion: Employing automated urinalysis seems to be accurate for detecting hematuria and leukocyturia, as well as for screening patients without kidney diseases. However, clinical laboratories attending complex patients should employ personalized strategies to help decide when to perform manual review, thus avoiding misleading urinalysis results.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用自动显微镜筛查尿液与参考人工分析相比的临床影响。
导言:临床实验室已用自动尿液分析仪取代了传统的人工尿液显微镜检查;然而,人们对自动尿液分析仪能否检测出对评估肾脏疾病至关重要的尿沉渣中的特定成分仍心存疑虑。本研究旨在评估一家大型医院实验室进行的尿沉渣分析与标准化显微镜检查相比的准确性,重点是肾脏疾病患者和非肾脏疾病患者:方法: 从一家大学医院的常规实验室标本中随机抽取尿液样本。实验室分析使用 LabUmat 2 和 Urised 3 PRO 设备(雅培诊断公司)进行。在自动分析过程中,技术人员可选择对尿沉渣元素进行重新分类,并在必要时进行人工显微评估以验证结果。实验室的分析结果与 "参考 "分析结果进行了比较,"参考 "分析由两名经验丰富的技术人员使用明视野显微镜和相位对比显微镜进行,采用双盲法:结果:共选取了 503 份样本,其中 52.3% 来自肾内科门诊病人。实验室结果与参考分析结果的总体一致性为 42.1%。实验室检查对病理铸型、脂尿和肾小管细胞的检测灵敏度(SN)较低(50%),而特异性(SP)较高(98%)。然而,对于透明样蛋白(SN:50.4%;SP:80.9%)和畸形红细胞(SN:62.3%;SP:96.2%),准确度处于中等水平。血尿(SN:86.1%;SP:82.3%;ICC:0.703;R:0.828)和白细胞尿(SN:84.9%;SP:95.1%;ICC:0.807;R:0.861)的准确率较高。在肾病患者(样本数=248)和实验室人工审核的样本(样本数=115)中,每种尿液元素的准确性与样本总体结果相当。然而,在评估识别肾病提示元素的能力时,只有实验室人工复核的样本与参考分析得出的结果在统计学上相似(P= 0.503,McNemar's 检验):结论:采用自动尿液分析仪检测血尿和白细胞尿以及筛查无肾脏疾病的患者似乎很准确。然而,治疗复杂病人的临床实验室应采用个性化策略,帮助决定何时进行人工复核,从而避免尿液分析结果产生误导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
American Journal of Nephrology
American Journal of Nephrology 医学-泌尿学与肾脏学
CiteScore
7.50
自引率
2.40%
发文量
74
审稿时长
4-8 weeks
期刊介绍: The ''American Journal of Nephrology'' is a peer-reviewed journal that focuses on timely topics in both basic science and clinical research. Papers are divided into several sections, including:
期刊最新文献
Cross-generational impact of maternal exposure to low level of PM2.5 on kidney health. Impact of Peritoneal Neutrophil Extracellular Traps on Peritoneal Characteristics and Technical Failure in Patients Undergoing Peritoneal Dialysis. Mineralocorticoid receptor antagonist combined with a SGLT2 inhibitor versus SGLT2 inhibitor alone in chronic kidney disease: a meta-analysis of randomized trials. The Interplay of Nonalcoholic Fatty Liver Disease and Chronic Kidney Disease: A Call for Integrated Management. Incidence of Adult Primary Immunoglobulin A Nephropathy Among a Racially/Ethnically Diverse Population in the United States.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1