Exploratory study on a novel minimally invasive tunnel like flap approach for orthodontic movement of dental implants.

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Oral Investigations Pub Date : 2024-10-14 DOI:10.1007/s00784-024-05992-w
Mahmoud Sedky Adly, Frederic Cuisinier, Aya Sedky Adly, Elias Estephan, Afnan Sedky Adly, Philippe Bousquet
{"title":"Exploratory study on a novel minimally invasive tunnel like flap approach for orthodontic movement of dental implants.","authors":"Mahmoud Sedky Adly, Frederic Cuisinier, Aya Sedky Adly, Elias Estephan, Afnan Sedky Adly, Philippe Bousquet","doi":"10.1007/s00784-024-05992-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To propose a new flap design that utilize a minimally invasive approach to move implants. We also propose a 3D method to track changes in implant position without the need for CBCT.</p><p><strong>Materials and methods: </strong>Implants were inserted in two mongrel dogs then a minimally invasive tunnel like flap was made. Bone cutting around implants was done using piezotome device and orthodontic force was applied on the implants. For tracking positional changes of implants, an impression was taken then scanned with an identical implant copy inside. The pre- and post-treatment 3D images were then superimposed over each other to detect changes in implant position.</p><p><strong>Results: </strong>Healing of the flap was rapid with minimal swelling and edema. The position of the interdental papilla was preserved maintaining optimal esthetic outcome. Implant pocket depth was maintained. Our 3D imaging method was able to accurately detect the movement that occurred in the dental implants after their movement with significantly higher resolution than CBCT (6 μm for this method versus 76-300 μm for the CBCT).</p><p><strong>Conclusions: </strong>This flap can preserve the esthetic soft tissue contour of implants during orthodontic movement allowing rapid healing with minimum swelling and edema. Moreover, our proposed 3D method has many advantages over CBCT in tracking the movement of implants by being non harmful and cheap thus allowing several follow up points.</p><p><strong>Clinical relevance: </strong>Orthodontic movement of implants can be required in cases of improperly placed implants or to intentionally place the implant in a certain position then altering it to avoid the need for bone grafting.</p>","PeriodicalId":10461,"journal":{"name":"Clinical Oral Investigations","volume":"28 11","pages":"595"},"PeriodicalIF":3.1000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Investigations","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00784-024-05992-w","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To propose a new flap design that utilize a minimally invasive approach to move implants. We also propose a 3D method to track changes in implant position without the need for CBCT.

Materials and methods: Implants were inserted in two mongrel dogs then a minimally invasive tunnel like flap was made. Bone cutting around implants was done using piezotome device and orthodontic force was applied on the implants. For tracking positional changes of implants, an impression was taken then scanned with an identical implant copy inside. The pre- and post-treatment 3D images were then superimposed over each other to detect changes in implant position.

Results: Healing of the flap was rapid with minimal swelling and edema. The position of the interdental papilla was preserved maintaining optimal esthetic outcome. Implant pocket depth was maintained. Our 3D imaging method was able to accurately detect the movement that occurred in the dental implants after their movement with significantly higher resolution than CBCT (6 μm for this method versus 76-300 μm for the CBCT).

Conclusions: This flap can preserve the esthetic soft tissue contour of implants during orthodontic movement allowing rapid healing with minimum swelling and edema. Moreover, our proposed 3D method has many advantages over CBCT in tracking the movement of implants by being non harmful and cheap thus allowing several follow up points.

Clinical relevance: Orthodontic movement of implants can be required in cases of improperly placed implants or to intentionally place the implant in a certain position then altering it to avoid the need for bone grafting.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型微创隧道式皮瓣法用于牙科植入物正畸移动的探索性研究。
目的:提出一种新的皮瓣设计,利用微创方法移动种植体。我们还提出了一种无需 CBCT 即可跟踪种植体位置变化的 3D 方法:在两只杂种狗身上植入种植体,然后制作一个类似隧道的微创皮瓣。使用压刀装置在种植体周围进行骨切割,并在种植体上施加正畸力。为了跟踪种植体的位置变化,先取一个印模,然后用一个相同的种植体副本进行扫描。然后将治疗前和治疗后的三维图像相互叠加,以检测种植体位置的变化:皮瓣愈合迅速,肿胀和水肿极小。结果:皮瓣愈合迅速,肿胀和水肿极小,牙间乳头的位置得以保留,保持了最佳的美学效果。种植袋深度保持不变。我们的三维成像方法能够准确检测到种植体移动后发生的移动,其分辨率明显高于 CBCT(该方法为 6 μm,而 CBCT 为 76-300 μm):结论:这种皮瓣可以在正畸移动过程中保持种植体的美学软组织轮廓,使其在肿胀和水肿最小的情况下快速愈合。此外,与 CBCT 相比,我们提出的三维方法在跟踪种植体移动方面具有许多优势,因为这种方法无损伤且成本低廉,因此可以进行多点跟踪:临床相关性:如果种植体放置不当,或有意将种植体放置在某个位置,然后改变位置以避免植骨,则需要对种植体进行正畸移动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Oral Investigations
Clinical Oral Investigations 医学-牙科与口腔外科
CiteScore
6.30
自引率
5.90%
发文量
484
审稿时长
3 months
期刊介绍: The journal Clinical Oral Investigations is a multidisciplinary, international forum for publication of research from all fields of oral medicine. The journal publishes original scientific articles and invited reviews which provide up-to-date results of basic and clinical studies in oral and maxillofacial science and medicine. The aim is to clarify the relevance of new results to modern practice, for an international readership. Coverage includes maxillofacial and oral surgery, prosthetics and restorative dentistry, operative dentistry, endodontics, periodontology, orthodontics, dental materials science, clinical trials, epidemiology, pedodontics, oral implant, preventive dentistiry, oral pathology, oral basic sciences and more.
期刊最新文献
Association of RS1126478 (LTF) with molar-incisor and generalized periodontitis. A technical note on the Kamranmeter; a manually operated device for measuring salivary spinnbarkeit. The clinical and microbiological efficacy of a zinc-citrate/hydroxyapatite/potassium-citrate containing toothpaste: a double-blind randomized controlled clinical trial. Fluorescence and color adjustment potentials of paste-type and flowable resin composites in cervical restorations. AI-driven segmentation of the pulp cavity system in mandibular molars on CBCT images using convolutional neural networks.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1