Comparative benefits of Ki and SUV images in lesion detection during PET/CT imaging.

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-10-16 DOI:10.1186/s13550-024-01162-x
Danjie Cai, Yibo He, Haojun Yu, Yiqiu Zhang, Hongcheng Shi
{"title":"Comparative benefits of Ki and SUV images in lesion detection during PET/CT imaging.","authors":"Danjie Cai, Yibo He, Haojun Yu, Yiqiu Zhang, Hongcheng Shi","doi":"10.1186/s13550-024-01162-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Clinical application of the tracer net influx rate (Ki) imaging in PET/CT remains limited, due to a lack of evidence demonstrating the superiority of Ki images in lesion detection, and guidelines on when to utilize Ki images. This study aims to compare the benefits of Ki and standardized uptake value (SUV) images in lesion detection during PET/CT imaging. By analyzing the performance of both techniques in identifying tumor lesions, the study seeks to provide guidance for the clinical application of Ki images.</p><p><strong>Results: </strong>This retrospective study included 134 patients with 244 pathologically confirmed lesions (200 malignant and 44 benign). Patients with a histopathological diagnosis received a weight-based <sup>18</sup>F-FDG injection and underwent 60-min total-body PET/CT dynamic imaging. SUV images were reconstructed using data collected from the last 10 min of the scans. Ki images were generated using the Patlak methods with data from minutes 12-60. The background SUV<sub>max</sub>, SUV<sub>mean</sub>, SUV<sub>SD</sub>, Ki<sub>max</sub>, Ki<sub>mean</sub>, and Ki<sub>SD</sub> values were recorded. The signal-to-noise ratios of the SUV (SUV<sub>SNR</sub>) and Ki (Ki<sub>SNR</sub>) images were calculated. The lesion detection rate and sensitivity of the SUV and Ki images were evaluated. The lesion-detection rates were 97.7% (214/219) and 99.5% (218/219) for the SUV and Ki images, respectively (p = .22). Five false-negative lesions on the SUV images were true-positive on the Ki images (3 hepatic malignancies and 2 metastatic lymph nodes). The sensitivity (94.0% vs. 96.0%, p = .22), specificity (41.9% vs. 41.9%, p > .99), accuracy (84.4% vs. 86.1%, p = .61), positive predictive value (87.9% vs. 88.1%, p = .94), negative predictive value (60.0% vs. 69.2%, p = .47), and the area under the curve [0.68 (95% confidence interval, 0.61-0.73) vs. 0.69 (95% confidence interval, 0.62-0.74)] were similar in the SUV and Ki images (all p ≥ .10).</p><p><strong>Conclusion: </strong>Ki images exhibit benefits in lesion detection compared to SUV images, particularly in organs with high background such as liver. The enhanced contrast provided by Ki imaging is recommended to clinically improve detection rates in such cases.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-10-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11485003/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13550-024-01162-x","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Clinical application of the tracer net influx rate (Ki) imaging in PET/CT remains limited, due to a lack of evidence demonstrating the superiority of Ki images in lesion detection, and guidelines on when to utilize Ki images. This study aims to compare the benefits of Ki and standardized uptake value (SUV) images in lesion detection during PET/CT imaging. By analyzing the performance of both techniques in identifying tumor lesions, the study seeks to provide guidance for the clinical application of Ki images.

Results: This retrospective study included 134 patients with 244 pathologically confirmed lesions (200 malignant and 44 benign). Patients with a histopathological diagnosis received a weight-based 18F-FDG injection and underwent 60-min total-body PET/CT dynamic imaging. SUV images were reconstructed using data collected from the last 10 min of the scans. Ki images were generated using the Patlak methods with data from minutes 12-60. The background SUVmax, SUVmean, SUVSD, Kimax, Kimean, and KiSD values were recorded. The signal-to-noise ratios of the SUV (SUVSNR) and Ki (KiSNR) images were calculated. The lesion detection rate and sensitivity of the SUV and Ki images were evaluated. The lesion-detection rates were 97.7% (214/219) and 99.5% (218/219) for the SUV and Ki images, respectively (p = .22). Five false-negative lesions on the SUV images were true-positive on the Ki images (3 hepatic malignancies and 2 metastatic lymph nodes). The sensitivity (94.0% vs. 96.0%, p = .22), specificity (41.9% vs. 41.9%, p > .99), accuracy (84.4% vs. 86.1%, p = .61), positive predictive value (87.9% vs. 88.1%, p = .94), negative predictive value (60.0% vs. 69.2%, p = .47), and the area under the curve [0.68 (95% confidence interval, 0.61-0.73) vs. 0.69 (95% confidence interval, 0.62-0.74)] were similar in the SUV and Ki images (all p ≥ .10).

Conclusion: Ki images exhibit benefits in lesion detection compared to SUV images, particularly in organs with high background such as liver. The enhanced contrast provided by Ki imaging is recommended to clinically improve detection rates in such cases.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
PET/CT 成像中 Ki 和 SUV 图像在病灶检测方面的优势比较。
背景:示踪剂净流入率(Ki)成像在 PET/CT 中的临床应用仍然有限,原因是缺乏证据证明 Ki 图像在病变检测中的优越性,以及何时使用 Ki 图像的指南。本研究旨在比较 Ki 和标准化摄取值 (SUV) 图像在 PET/CT 成像中病灶检测的优势。通过分析两种技术在识别肿瘤病灶方面的表现,该研究旨在为 Ki 图像的临床应用提供指导:这项回顾性研究包括 134 名患者,244 个病理确诊病灶(200 个恶性,44 个良性)。组织病理学确诊的患者接受了基于体重的 18F-FDG 注射,并进行了 60 分钟的全身 PET/CT 动态成像。利用扫描最后 10 分钟收集的数据重建 SUV 图像。Ki图像采用Patlak方法,使用第12-60分钟的数据生成。记录了背景 SUVmax、SUVmean、SUVSD、Kimax、Kimean 和 KiSD 值。计算 SUV(SUVSNR)和 Ki(KiSNR)图像的信噪比。评估了 SUV 和 Ki 图像的病灶检测率和灵敏度。SUV和Ki图像的病灶检出率分别为97.7%(214/219)和99.5%(218/219)(p = .22)。SUV 图像上的 5 个假阴性病灶在 Ki 图像上呈真阳性(3 个肝恶性肿瘤和 2 个转移淋巴结)。SUV和Ki图像的曲线下面积[0.68(95%置信区间,0.61-0.73)vs.0.69(95%置信区间,0.62-0.74)]相似(所有P均≥.10):结论:与 SUV 图像相比,Ki 图像在病灶检测方面具有优势,尤其是在肝脏等高背景器官中。结论:Ki 图像与 SUV 图像相比在病变检测方面具有优势,尤其是在肝脏等背景较高的器官中,Ki 图像提供的增强对比度可提高此类病例的临床检测率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊最新文献
Correction: Novel Insights into Causal Effects of Serum Lipids and Apolipoproteins on Cardiovascular Morpho-Functional Phenotypes. Cardiogenic Shock: Focus on Non-Cardiac Biomarkers. Comment to the article titled: sympathetic dysfunction as an early indicator of autonomic involvement in Parkinson's disease. Glycosylation in Drosophila S2 cells. Sequential delivery of photosensitizers and checkpoint inhibitors by engineered bacteria for enhanced cancer photodynamic immunotherapy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1