{"title":"Single catheter ablation of atrioventricular node in a patient with dextrocardia and permanent atrial fibrillation via peripheral vascular access using remote magnetic navigation: a case report.","authors":"Pekka Raatikainen, Annukka Marjamaa, Heli Tolppanen, Jarkko Karvonen, Aapo Aro","doi":"10.1093/ehjcr/ytae510","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Cardiac interventions may be challenging in patients with congenital cardiac abnormalities. This case reports cardiac resynchronization therapy pacemaker (CRT-P) implantation and single catheter ablation of atrioventricular node (AVN) with remote magnetic navigation (RMN) via peripheral vascular access in a patient with Kartagener's syndrome and permanent atrial fibrillation (AF).</p><p><strong>Case summary: </strong>A 74-year-old male with situs inversus presented for treatment of permanent AF and severe heart failure. In echocardiography, left ventricular ejection fraction was 30%, and there was severe dyskinesia due to a left bundle branch block. After successful CRT-P implantation, we performed AVN ablation because biventricular (BiV) pacing was <75% despite maximal rate control medication. The ablation catheter was inserted from the right basilic vein, and no other catheters were used. Despite peripheral vascular access, manipulation of the ablation catheter with RMN was easy, and the ablation was successful. After the ablation, BiV pacing instantly increased to 100%, and left ventricular function and symptomatic status improved gradually.</p><p><strong>Conclusions: </strong>Cardiac resynchronization therapy pacemaker implantation and RMN-guided single catheter ablation of the AVN in a patient with dextrocardia via peripheral vascular access was effective and safe. The use of RMN and peripheral vascular access may offer important advantages also in other patient groups.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11487482/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjcr/ytae510","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Cardiac interventions may be challenging in patients with congenital cardiac abnormalities. This case reports cardiac resynchronization therapy pacemaker (CRT-P) implantation and single catheter ablation of atrioventricular node (AVN) with remote magnetic navigation (RMN) via peripheral vascular access in a patient with Kartagener's syndrome and permanent atrial fibrillation (AF).

Case summary: A 74-year-old male with situs inversus presented for treatment of permanent AF and severe heart failure. In echocardiography, left ventricular ejection fraction was 30%, and there was severe dyskinesia due to a left bundle branch block. After successful CRT-P implantation, we performed AVN ablation because biventricular (BiV) pacing was <75% despite maximal rate control medication. The ablation catheter was inserted from the right basilic vein, and no other catheters were used. Despite peripheral vascular access, manipulation of the ablation catheter with RMN was easy, and the ablation was successful. After the ablation, BiV pacing instantly increased to 100%, and left ventricular function and symptomatic status improved gradually.

Conclusions: Cardiac resynchronization therapy pacemaker implantation and RMN-guided single catheter ablation of the AVN in a patient with dextrocardia via peripheral vascular access was effective and safe. The use of RMN and peripheral vascular access may offer important advantages also in other patient groups.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
使用远程磁导航,通过外周血管通道对一名患有右心室和永久性心房颤动的患者进行房室结单导管消融术:病例报告。
背景:先天性心脏畸形患者的心脏介入治疗可能具有挑战性。本病例报告了在一名患有卡塔格纳综合征和永久性房颤(AF)的患者身上植入心脏再同步治疗起搏器(CRT-P),并通过外周血管入路采用远程磁导航(RMN)对房室结(AVN)进行单导管消融。超声心动图显示,左室射血分数为 30%,左束支传导阻滞导致严重的运动障碍。成功植入 CRT-P 后,我们进行了房室网消融术,因为双心室(BiV)起搏得出了结论:通过外周血管通路为一名右心室缺血患者植入心脏再同步治疗起搏器并在 RMN 引导下进行单导管房室网消融术是有效而安全的。在其他患者群体中使用 RMN 和外周血管通路可能也具有重要优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1