A U-turn wiring technique for reverse-angled branches adjacent to ectasia: a case series.

Pub Date : 2024-09-27 eCollection Date: 2024-10-01 DOI:10.1093/ehjcr/ytae537
Masashi Yamaguchi, Yutaka Tanaka, Daisuke Sato, Shigeru Saito
{"title":"A U-turn wiring technique for reverse-angled branches adjacent to ectasia: a case series.","authors":"Masashi Yamaguchi, Yutaka Tanaka, Daisuke Sato, Shigeru Saito","doi":"10.1093/ehjcr/ytae537","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The reverse-wiring technique (RWT) using a hairpin-bend wire is useful for percutaneous coronary intervention of a bifurcation lesion with an extremely angulated side branch (SB); however, it is not necessarily effective in some anatomical situations. We report a novel SB wiring technique, the U-turn wiring technique (UWT), that is useful for wiring an extremely angled SB proximal to the ectasia.</p><p><strong>Case summary: </strong>In the first case, the bare wire took a U-turn in the ectasia of the diagonal branch and crossed towards the angled left anterior descending artery, but a coronary dissection occurred in the diagonal branch due to the continuous wire-pushing force. Therefore, in the second case, we used a microcatheter with distal flexibility to prevent guidewire-induced vessel injury at the ectasia site and safely advanced the wire to the distal portion of the extremely angulated SB.</p><p><strong>Discussion: </strong>The UWT takes advantage of the ectasia as a space to U-turn the guidewire. The UWT does not require a hairpin-bend guidewire or a dual-lumen catheter. The guidewire can be easily pushed forward through a reversed SB. After successful wire insertion, the guidewire can be easily advanced deep into the side branch. The UWT facilitates wire crossing to a reverse-angled branch utilizing the coronary ectasia anatomy through a simple manipulation.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11489872/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjcr/ytae537","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The reverse-wiring technique (RWT) using a hairpin-bend wire is useful for percutaneous coronary intervention of a bifurcation lesion with an extremely angulated side branch (SB); however, it is not necessarily effective in some anatomical situations. We report a novel SB wiring technique, the U-turn wiring technique (UWT), that is useful for wiring an extremely angled SB proximal to the ectasia.

Case summary: In the first case, the bare wire took a U-turn in the ectasia of the diagonal branch and crossed towards the angled left anterior descending artery, but a coronary dissection occurred in the diagonal branch due to the continuous wire-pushing force. Therefore, in the second case, we used a microcatheter with distal flexibility to prevent guidewire-induced vessel injury at the ectasia site and safely advanced the wire to the distal portion of the extremely angulated SB.

Discussion: The UWT takes advantage of the ectasia as a space to U-turn the guidewire. The UWT does not require a hairpin-bend guidewire or a dual-lumen catheter. The guidewire can be easily pushed forward through a reversed SB. After successful wire insertion, the guidewire can be easily advanced deep into the side branch. The UWT facilitates wire crossing to a reverse-angled branch utilizing the coronary ectasia anatomy through a simple manipulation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
邻近异位症的反向角状分支的 U 型转弯布线技术:病例系列。
背景:使用发夹弯导线的反向布线技术(RWT)可用于经皮冠状动脉介入治疗侧支(SB)角度极大的分叉病变,但在某些解剖情况下并不一定有效。病例摘要:在第一个病例中,裸导线在斜支的异位处拐了一个U形弯,并向成角的左前降支动脉方向穿过,但由于持续的导线推力,斜支发生了冠状动脉夹层。因此,在第二个病例中,我们使用了具有远端灵活性的微导管,以防止导丝在异位部位引起血管损伤,并安全地将导丝推进到极度成角的 SB 远端:讨论:UWT 利用异位作为导丝调头的空间。UWT 不需要发夹弯导丝或双腔导管。导丝可以很容易地通过反向的 SB 向前推进。成功插入导丝后,导丝可轻松深入侧支。通过简单的操作,UWT 便可利用冠状动脉异位的解剖结构将导线穿过反向角支。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1