Effects of different orthokeratology lens designs on slowing axial length elongation in children with myopia.

IF 1.9 4区 医学 Q2 OPHTHALMOLOGY International journal of ophthalmology Pub Date : 2024-10-18 eCollection Date: 2024-01-01 DOI:10.18240/ijo.2024.10.10
Hai-Long Ni, Xiang Chen, Du-Ya Chen, Pei-Ke Hu, Zhi-Yi Wu
{"title":"Effects of different orthokeratology lens designs on slowing axial length elongation in children with myopia.","authors":"Hai-Long Ni, Xiang Chen, Du-Ya Chen, Pei-Ke Hu, Zhi-Yi Wu","doi":"10.18240/ijo.2024.10.10","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>To elucidate whether differences exist in the impact on retarding the elongation of axial length (AL) among children with myopia when utilizing orthokeratology (ortho-k) lenses employing the corneal refractive therapy (CRT) design versus those employing the vision shaping treatment (VST) design.</p><p><strong>Methods: </strong>This retrospective clinical trial aimed to collect and analyze AL data from individuals who wore ortho-k lenses for three years. A total of 654 subjects were enrolled and prescribed one of the three specific brands of ortho-k lenses: CRT, Euclid, and Mouldway. The study's primary focus was to compare the rates of AL elongation and myopic progression across these three brands of ortho-k lenses.</p><p><strong>Results: </strong>In the 3-year follow-up, the AL elongation exhibited variations of 0.73±0.36 mm in the CRT lens group, 0.59±0.37 mm in the Euclid lens group, and 0.63±0.38 mm in the Mouldway lens group. A noteworthy disparity emerged between the CRT and Mouldway groups (<i>P</i><0.01), as well as between the CRT and Euclid groups (<i>P</i><0.001). Additionally, it was observed that 32.1% of participants who wore CRT lenses experienced a decelerated progression of myopia, in contrast to 47.2% in the Euclid group and 44.4% in the Mouldway group. Statistical analyses revealed a statistically significant distinction between the CRT and Euclid groups (<i>P</i><0.01), and similarly, the CRT group demonstrated a statistically significant difference when compared to the Mouldway group (<i>P</i><0.05).</p><p><strong>Conclusion: </strong>Ortho-k lenses represent a pragmatic strategy for mitigating the advancement of myopia. In contradistinction to ortho-k lenses utilizing the CRT design, those employing the VST design exhibited a more favorable impact regarding retarding AL elongation.</p>","PeriodicalId":14312,"journal":{"name":"International journal of ophthalmology","volume":"17 10","pages":"1843-1849"},"PeriodicalIF":1.9000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11422374/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.18240/ijo.2024.10.10","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: To elucidate whether differences exist in the impact on retarding the elongation of axial length (AL) among children with myopia when utilizing orthokeratology (ortho-k) lenses employing the corneal refractive therapy (CRT) design versus those employing the vision shaping treatment (VST) design.

Methods: This retrospective clinical trial aimed to collect and analyze AL data from individuals who wore ortho-k lenses for three years. A total of 654 subjects were enrolled and prescribed one of the three specific brands of ortho-k lenses: CRT, Euclid, and Mouldway. The study's primary focus was to compare the rates of AL elongation and myopic progression across these three brands of ortho-k lenses.

Results: In the 3-year follow-up, the AL elongation exhibited variations of 0.73±0.36 mm in the CRT lens group, 0.59±0.37 mm in the Euclid lens group, and 0.63±0.38 mm in the Mouldway lens group. A noteworthy disparity emerged between the CRT and Mouldway groups (P<0.01), as well as between the CRT and Euclid groups (P<0.001). Additionally, it was observed that 32.1% of participants who wore CRT lenses experienced a decelerated progression of myopia, in contrast to 47.2% in the Euclid group and 44.4% in the Mouldway group. Statistical analyses revealed a statistically significant distinction between the CRT and Euclid groups (P<0.01), and similarly, the CRT group demonstrated a statistically significant difference when compared to the Mouldway group (P<0.05).

Conclusion: Ortho-k lenses represent a pragmatic strategy for mitigating the advancement of myopia. In contradistinction to ortho-k lenses utilizing the CRT design, those employing the VST design exhibited a more favorable impact regarding retarding AL elongation.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同角膜塑形镜设计对减缓近视儿童轴长伸长的影响。
目的:阐明采用角膜屈光治疗(CRT)设计的角膜塑形镜(orthok)与采用视力塑形治疗(VST)设计的角膜塑形镜在延缓近视儿童轴长(AL)方面是否存在差异:这项回顾性临床试验旨在收集和分析配戴角膜塑形镜三年的 AL 数据。共有 654 名受试者参加了试验,并获得了三种特定品牌矫形 K 镜片中的一种:CRT、Euclid 和 Mouldway。研究的主要重点是比较这三种品牌的角膜塑形镜的AL伸长率和近视度数加深率:结果:在三年的随访中,CRT镜片组的AL伸长率为(0.73±0.36)毫米,Euclid镜片组为(0.59±0.37)毫米,Mouldway镜片组为(0.63±0.38)毫米。CRT 组和 Mouldway 组之间出现了值得注意的差异(PPPPC 结论:角膜塑形镜是缓解近视加深的实用策略。与采用 CRT 设计的角膜塑形镜相反,采用 VST 设计的角膜塑形镜在延缓 AL 拉长方面表现出更有利的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.50
自引率
7.10%
发文量
3141
审稿时长
4-8 weeks
期刊介绍: · International Journal of Ophthalmology-IJO (English edition) is a global ophthalmological scientific publication and a peer-reviewed open access periodical (ISSN 2222-3959 print, ISSN 2227-4898 online). This journal is sponsored by Chinese Medical Association Xi’an Branch and obtains guidance and support from WHO and ICO (International Council of Ophthalmology). It has been indexed in SCIE, PubMed, PubMed-Central, Chemical Abstracts, Scopus, EMBASE , and DOAJ. IJO JCR IF in 2017 is 1.166. IJO was established in 2008, with editorial office in Xi’an, China. It is a monthly publication. General Scientific Advisors include Prof. Hugh Taylor (President of ICO); Prof.Bruce Spivey (Immediate Past President of ICO); Prof.Mark Tso (Ex-Vice President of ICO) and Prof.Daiming Fan (Academician and Vice President, Chinese Academy of Engineering. International Scientific Advisors include Prof. Serge Resnikoff (WHO Senior Speciatist for Prevention of blindness), Prof. Chi-Chao Chan (National Eye Institute, USA) and Prof. Richard L Abbott (Ex-President of AAO/PAAO) et al. Honorary Editors-in-Chief: Prof. Li-Xin Xie(Academician of Chinese Academy of Engineering/Honorary President of Chinese Ophthalmological Society); Prof. Dennis Lam (President of APAO) and Prof. Xiao-Xin Li (Ex-President of Chinese Ophthalmological Society). Chief Editor: Prof. Xiu-Wen Hu (President of IJO Press). Editors-in-Chief: Prof. Yan-Nian Hui (Ex-Director, Eye Institute of Chinese PLA) and Prof. George Chiou (Founding chief editor of Journal of Ocular Pharmacology & Therapeutics). Associate Editors-in-Chief include: Prof. Ning-Li Wang (President Elect of APAO); Prof. Ke Yao (President of Chinese Ophthalmological Society) ; Prof.William Smiddy (Bascom Palmer Eye instituteUSA) ; Prof.Joel Schuman (President of Association of University Professors of Ophthalmology,USA); Prof.Yizhi Liu (Vice President of Chinese Ophtlalmology Society); Prof.Yu-Sheng Wang (Director of Eye Institute of Chinese PLA); Prof.Ling-Yun Cheng (Director of Ocular Pharmacology, Shiley Eye Center, USA). IJO accepts contributions in English from all over the world. It includes mainly original articles and review articles, both basic and clinical papers. Instruction is Welcome Contribution is Welcome Citation is Welcome Cooperation organization International Council of Ophthalmology(ICO), PubMed, PMC, American Academy of Ophthalmology, Asia-Pacific, Thomson Reuters, The Charlesworth Group, Crossref,Scopus,Publons, DOAJ etc.
期刊最新文献
Purtscher-like retinopathy associated with COVID-19: a case report. Recurrent corneal erosion after buried-suture double-eyelid blepharoplasty using barbed thread. Retinal capillary density among healthy Egyptian and South Asian students: an optical coherence tomography angiography study. Risk factors for biometry prediction error by Barrett Universal II intraocular lens formula in Chinese patients. Topographic factors associated with anterior chamber angle narrowing in patients with keratoconus.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1