Prospective Evaluation of Clinical and Patient-Reported Outcomes Following Contralateral Implantation of an Extended Depth of Focus (EDOF) and Hybrid EDOF-Multifocal IOL.

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY Journal of refractive surgery Pub Date : 2024-10-01 DOI:10.3928/1081597X-20240805-02
George O Waring, Arthur B van den Berg, Roberta M van den Berg, Karolinne M Rocha
{"title":"Prospective Evaluation of Clinical and Patient-Reported Outcomes Following Contralateral Implantation of an Extended Depth of Focus (EDOF) and Hybrid EDOF-Multifocal IOL.","authors":"George O Waring, Arthur B van den Berg, Roberta M van den Berg, Karolinne M Rocha","doi":"10.3928/1081597X-20240805-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate clinical outcomes following contralateral implantation of a diffractive extended depth of focus (EDOF) and a hybrid EDOF-multifocal intraocular lens (IOL) with a violet filter in a U.S.-based population.</p><p><strong>Methods: </strong>In this prospective, non-comparative study, 60 eyes of 30 patients aged 40 years and older underwent bilateral cataract surgery and implantation of a DXR00V IOL (Tecnis Symfony OptiBlue) in the dominant eye and a DFR00V (Tecnis Synergy) IOL in the non-dominant eye. Outcome measures included uncorrected (UDVA) and corrected (CDVA) distance visual acuity, distance-corrected intermediate (DCIVA, 66 cm), near and very near visual acuity (DCNVA, 40 and 33 cm), and patient-reported outcomes.</p><p><strong>Results: </strong>At 6 months postoperatively, binocular mean UDVA and CDVA were -0.10 ± 0.07 and -0.11 ± 0.05 logarithm of the minimum angle of resolution (logMAR), respectively. The mean DCIVA was 0.26 ± 0.08 logMAR in the DXR00V eyes and 0.23 ± 0.06 logMAR in the DFR00V eyes. The mean DCNVA at 40 and 33 cm were 0.28 ± 0.12 and 0.30 ± 0.15 logMAR, respectively, in the DXR00V eyes and 0.07 ± 0.08 and 0.07 ± 0.10 logMAR, respectively, in the DFR00V eyes. The mean binocular DCIVA and DCNVA at 33 and 40 cm were 0.18 ± 0.05, 0.06 ± 0.08, and 0.06 ± 0.07 logMAR, respectively. The percentages of patients achieving spectacle independence at far, intermediate, and near distances were 100%, 100%, and 81%, respectively.</p><p><strong>Conclusions: </strong>Contralateral implantation of the diffractive EDOF and a hybrid EDOF-multifocal IOL yielded excellent binocular visual acuity at all distances, as well as high patient satisfaction and functional performance on visual tasks. <b>[<i>J Refract Surg</i>. 2024;40(10):e699-e705.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 10","pages":"e699-e705"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240805-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate clinical outcomes following contralateral implantation of a diffractive extended depth of focus (EDOF) and a hybrid EDOF-multifocal intraocular lens (IOL) with a violet filter in a U.S.-based population.

Methods: In this prospective, non-comparative study, 60 eyes of 30 patients aged 40 years and older underwent bilateral cataract surgery and implantation of a DXR00V IOL (Tecnis Symfony OptiBlue) in the dominant eye and a DFR00V (Tecnis Synergy) IOL in the non-dominant eye. Outcome measures included uncorrected (UDVA) and corrected (CDVA) distance visual acuity, distance-corrected intermediate (DCIVA, 66 cm), near and very near visual acuity (DCNVA, 40 and 33 cm), and patient-reported outcomes.

Results: At 6 months postoperatively, binocular mean UDVA and CDVA were -0.10 ± 0.07 and -0.11 ± 0.05 logarithm of the minimum angle of resolution (logMAR), respectively. The mean DCIVA was 0.26 ± 0.08 logMAR in the DXR00V eyes and 0.23 ± 0.06 logMAR in the DFR00V eyes. The mean DCNVA at 40 and 33 cm were 0.28 ± 0.12 and 0.30 ± 0.15 logMAR, respectively, in the DXR00V eyes and 0.07 ± 0.08 and 0.07 ± 0.10 logMAR, respectively, in the DFR00V eyes. The mean binocular DCIVA and DCNVA at 33 and 40 cm were 0.18 ± 0.05, 0.06 ± 0.08, and 0.06 ± 0.07 logMAR, respectively. The percentages of patients achieving spectacle independence at far, intermediate, and near distances were 100%, 100%, and 81%, respectively.

Conclusions: Contralateral implantation of the diffractive EDOF and a hybrid EDOF-multifocal IOL yielded excellent binocular visual acuity at all distances, as well as high patient satisfaction and functional performance on visual tasks. [J Refract Surg. 2024;40(10):e699-e705.].

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
前瞻性评估对侧植入延伸焦深 (EDOF) 和混合型 EDOF 多焦人工晶体后的临床和患者报告结果。
目的:评估在美国人群中对侧植入衍射性延伸焦深(EDOF)和带紫色滤光片的混合型 EDOF 多焦点眼内人工晶体(IOL)后的临床效果:在这项前瞻性、非比较研究中,30 名 40 岁及以上患者的 60 只眼睛接受了双侧白内障手术,并在优势眼植入了 DXR00V 人工晶体(Tecnis Symfony OptiBlue),在非优势眼植入了 DFR00V 人工晶体(Tecnis Synergy)。结果测量包括未校正(UDVA)和校正(CDVA)远距离视力、校正中距离视力(DCIVA,66 厘米)、近距离和极近距离视力(DCNVA,40 厘米和 33 厘米)以及患者报告的结果:术后 6 个月,双眼平均 UDVA 和 CDVA 分别为 -0.10 ± 0.07 和 -0.11 ± 0.05 最小解像角对数(logMAR)。DXR00V 双眼的平均 DCIVA 为 0.26 ± 0.08 logMAR,DFR00V 双眼的平均 DCIVA 为 0.23 ± 0.06 logMAR。DXR00V 双眼在 40 厘米和 33 厘米处的平均 DCNVA 分别为 0.28 ± 0.12 和 0.30 ± 0.15 logMAR,DFR00V 双眼分别为 0.07 ± 0.08 和 0.07 ± 0.10 logMAR。33 厘米和 40 厘米处的平均双眼 DCIVA 和 DCNVA 分别为 0.18 ± 0.05、0.06 ± 0.08 和 0.06 ± 0.07 logMAR。在远距离、中距离和近距离实现眼镜独立的患者比例分别为 100%、100% 和 81%:衍射型 EDOF 和混合型 EDOF 多焦点人工晶体的对侧植入在所有距离上都能获得极佳的双眼视力,患者满意度高,视觉任务的功能表现也很好。[J Refract Surg. 2024;40(10):e699-e705]。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
期刊最新文献
Clinical Comparison of Decentration and Tilt Effects in Iris-Claw and Trans-scleral Plug Lenses: Wavefront Analysis With a Pyramidal Sensor Aberrometer. Clipped Topography-Guided Treatments: A Different Approach to Custom Corrections. Comparison of the Visual Outcomes and Optical Quality of Small Incision Lenticule Extraction and Toric Implantable Collamer Lens Implantation to Correct High Astigmatism. Effects and Related Factors of Short-time Accommodation Training on Measuring Consistency of InnovEyes Sitemap, Autorefraction, and Subjective Refraction. Effects of Ocular Residual Astigmatism on Refractive Outcomes for Myopia Correction After Keratorefractive Lenticule Extraction Surgery.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1