Comparing the Accuracy of Conventional Gypsum and 3D-Printed Dental Casts Using Three-Dimensional Analysis.

IF 1.2 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL Military Medicine Pub Date : 2024-10-14 DOI:10.1093/milmed/usae479
Bradley J Thomson, Eric Hu, Robert Masterson
{"title":"Comparing the Accuracy of Conventional Gypsum and 3D-Printed Dental Casts Using Three-Dimensional Analysis.","authors":"Bradley J Thomson, Eric Hu, Robert Masterson","doi":"10.1093/milmed/usae479","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Dental impressions and casts play a critical role in dental care, facilitating diagnoses and the fabrication of prostheses. Traditional methods of fabrication involve elastomeric materials that are more prone to errors and patient discomfort. Digital advancements offer promising alternatives, yet their accuracy and applicability to military dentistry remain under-explored. This study evaluates the accuracy of digital casts produced with material available in the Military Health System compared to conventional methods.</p><p><strong>Materials and methods: </strong>Using a digital (n = 10) and analog (n = 10) methodology casts were fabricated from a reference cast (n = 1). The reference and cast samples were scanned with a reference scanner to generate stereolithography files. These files were used to generate full arch, single crown, fixed dental prosthesis, and inlay digital casts which were then compared using a three-dimensional (3D) comparison software to evaluate accuracy. Root mean square values were obtained, giving a quantitative evaluation of the deviation of each sample from the reference cast. Statistical analysis consisted of a Shapiro-Wilk and Levene test to account for homogeneity of variances in each group. An ANOVA and Tukey post-hoc test were used to determine differences in accuracy among the full arch and a two-way ANOVA and Tukey post-hoc test evaluated differences in trueness among the casts of the individual preparations.</p><p><strong>Results: </strong>Analog full arch casts had an average root mean square of 106 ±19.18 µm when examining trueness and 12 ±2.58 µm for precision. Digital full arch casts had an average root mean square of 51.9 ±5.39 µm when examining trueness and 4.2 ±1.57 µm for precision. Overall digital casts surpassed analog counterparts in accuracy. Fixed dental prostheses were found to be the only group, which showed no statistically significant difference between digital and analog.</p><p><strong>Conclusion: </strong>These findings validate the potential of digital workflows in enhancing the speed and accuracy of dental care in the Military Health System, while underscoring the need for further exploration and refinement in specific clinical contexts.</p>","PeriodicalId":18638,"journal":{"name":"Military Medicine","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Military Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/milmed/usae479","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Dental impressions and casts play a critical role in dental care, facilitating diagnoses and the fabrication of prostheses. Traditional methods of fabrication involve elastomeric materials that are more prone to errors and patient discomfort. Digital advancements offer promising alternatives, yet their accuracy and applicability to military dentistry remain under-explored. This study evaluates the accuracy of digital casts produced with material available in the Military Health System compared to conventional methods.

Materials and methods: Using a digital (n = 10) and analog (n = 10) methodology casts were fabricated from a reference cast (n = 1). The reference and cast samples were scanned with a reference scanner to generate stereolithography files. These files were used to generate full arch, single crown, fixed dental prosthesis, and inlay digital casts which were then compared using a three-dimensional (3D) comparison software to evaluate accuracy. Root mean square values were obtained, giving a quantitative evaluation of the deviation of each sample from the reference cast. Statistical analysis consisted of a Shapiro-Wilk and Levene test to account for homogeneity of variances in each group. An ANOVA and Tukey post-hoc test were used to determine differences in accuracy among the full arch and a two-way ANOVA and Tukey post-hoc test evaluated differences in trueness among the casts of the individual preparations.

Results: Analog full arch casts had an average root mean square of 106 ±19.18 µm when examining trueness and 12 ±2.58 µm for precision. Digital full arch casts had an average root mean square of 51.9 ±5.39 µm when examining trueness and 4.2 ±1.57 µm for precision. Overall digital casts surpassed analog counterparts in accuracy. Fixed dental prostheses were found to be the only group, which showed no statistically significant difference between digital and analog.

Conclusion: These findings validate the potential of digital workflows in enhancing the speed and accuracy of dental care in the Military Health System, while underscoring the need for further exploration and refinement in specific clinical contexts.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用三维分析比较传统石膏牙模和三维打印牙模的精确度
简介牙模和石膏在牙科护理中发挥着至关重要的作用,有助于诊断和制作义齿。传统的制作方法使用的是弹性材料,容易出现误差和患者不适。数字技术的发展提供了前景广阔的替代方法,但其准确性和在军事牙科中的适用性仍未得到充分探索。与传统方法相比,本研究评估了使用军事卫生系统现有材料制作的数字化铸模的准确性:使用数字(n = 10)和模拟(n = 10)方法从参考铸型(n = 1)制作铸型。用参考扫描仪扫描参考和铸模样本,生成立体光刻文件。使用这些文件生成全牙弓、单冠、固定义齿和镶嵌数字铸模,然后使用三维(3D)比较软件对这些铸模进行比较,以评估准确性。获得的均方根值可定量评估每个样本与参考模型的偏差。统计分析包括 Shapiro-Wilk 和 Levene 检验,以确定各组的方差均一性。方差分析和Tukey事后检验用于确定全牙弓精确度的差异,双向方差分析和Tukey事后检验用于评估单个制备的铸模在真实度上的差异:模拟全牙弓模型的真实度平均均方根为 106 ±19.18 µm,精确度为 12 ±2.58 µm。数字全牙弓模型的真实度平均均方根为 51.9 ± 5.39 µm,精度为 4.2 ± 1.57 µm。总体而言,数字铸模的精确度超过了模拟铸模。结论:这些研究结果验证了数字化工作的潜力:这些发现验证了数字化工作流程在提高军事卫生系统牙科护理的速度和准确性方面的潜力,同时也强调了在特定临床环境中进一步探索和完善的必要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Military Medicine
Military Medicine MEDICINE, GENERAL & INTERNAL-
CiteScore
2.20
自引率
8.30%
发文量
393
审稿时长
4-8 weeks
期刊介绍: Military Medicine is the official international journal of AMSUS. Articles published in the journal are peer-reviewed scientific papers, case reports, and editorials. The journal also publishes letters to the editor. The objective of the journal is to promote awareness of federal medicine by providing a forum for responsible discussion of common ideas and problems relevant to federal healthcare. Its mission is: To increase healthcare education by providing scientific and other information to its readers; to facilitate communication; and to offer a prestige publication for members’ writings.
期刊最新文献
Fatigue and Sleep-related Impairment as Predictors of the Effect of Nonpharmacological Therapies for Active duty Service Members With Chronic Pain: A Secondary Analysis of a Pragmatic Randomized Clinical Trial. Challenges to School Success Among Children in U.S. Military Families. Combat-Relevant Anesthesia Fellowships Help Sustain the Army's Multidomain Medical Force. Preparing Military Interprofessional Health Care Teams for Effective Collaboration. Synopsis of the 2023 U.S. Department of VA and U.S. DoD Clinical Practice Guideline for the Management of Pregnancy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1