Effect of Battery Level During Successive Charging Cycles on the Performance of Certified and Low-cost Uncertified Light-curing Units Available on E-commerce.

IF 1.4 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE Operative dentistry Pub Date : 2024-11-01 DOI:10.2341/23-177-L
T S Peres, G Oliveira, S P da Silva Sakamoto, M da Silva Faria, H L Carlo, C J Soares
{"title":"Effect of Battery Level During Successive Charging Cycles on the Performance of Certified and Low-cost Uncertified Light-curing Units Available on E-commerce.","authors":"T S Peres, G Oliveira, S P da Silva Sakamoto, M da Silva Faria, H L Carlo, C J Soares","doi":"10.2341/23-177-L","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the influence of battery level on power (mW), emission spectrum (mW/cm2/ nm), and light distribution on the active tip (mW/ cm2) of certified (FDA/ANVISA) and low-cost uncertified light-curing units (LCUs) purchased through e-commerce.</p><p><strong>Methods: </strong>Seven LCUs, three certified: VALO Grand (Ultradent); Radii Xpert (SDI); and LED.B (Woodpecker); and four uncertified: 1 Sec; BS 300; LED curing light; and VAFU (VRN, AZDENT), were used. The LCUs were evaluated by calculating the power (mW) after each sequential five exposure cycles of 20 seconds and the emission spectrum (mW/cm2/nm) in the initial and final cycles, using an integrating sphere during three battery charging cycles. Beam profiling was used to check the light distribution on the LCU tip after every 50 exposure cycles until the battery fully discharged. Data were analyzed by linear regression between power and the number of exposure times (R2).</p><p><strong>Results: </strong>The certified LCUs VALO Grand (R2=0.005), LED.B (R2=0.02), and Radii Xpert (R2=0.09) and the uncertified LCU VAFU (R2=0.002) had no significant power reduction during the three battery charging cycles. The uncertified LCUs BS 300 (R2=0.87), 1 Sec (R2=0.60), and LED curing light (R2=0.83) showed significant power reduction, decreasing the emission spectrum (mW/cm2/nm) at the end of the battery charging cycle. The light distribution on the active tip across the level battery was modified significantly with successive exposure times.</p><p><strong>Conclusions: </strong>The certified LCUs (VALO Grand, Radii Xpert, and LED.B) and uncertified LCU (VAFU), maintained power, emission spectrum, and light distributions during the tested battery life cycles. Low-cost certified LCU LED.B exhibited inhomogeneous light concentrated at the center of the tip. Low-cost uncertified LCUs-BS 300, 1 Sec, and LED curing light-had significant power reductions during the battery cycles and increased inhomogeneous light distribution along the successive exposure times.</p>","PeriodicalId":19502,"journal":{"name":"Operative dentistry","volume":" ","pages":"673-681"},"PeriodicalIF":1.4000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Operative dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2341/23-177-L","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the influence of battery level on power (mW), emission spectrum (mW/cm2/ nm), and light distribution on the active tip (mW/ cm2) of certified (FDA/ANVISA) and low-cost uncertified light-curing units (LCUs) purchased through e-commerce.

Methods: Seven LCUs, three certified: VALO Grand (Ultradent); Radii Xpert (SDI); and LED.B (Woodpecker); and four uncertified: 1 Sec; BS 300; LED curing light; and VAFU (VRN, AZDENT), were used. The LCUs were evaluated by calculating the power (mW) after each sequential five exposure cycles of 20 seconds and the emission spectrum (mW/cm2/nm) in the initial and final cycles, using an integrating sphere during three battery charging cycles. Beam profiling was used to check the light distribution on the LCU tip after every 50 exposure cycles until the battery fully discharged. Data were analyzed by linear regression between power and the number of exposure times (R2).

Results: The certified LCUs VALO Grand (R2=0.005), LED.B (R2=0.02), and Radii Xpert (R2=0.09) and the uncertified LCU VAFU (R2=0.002) had no significant power reduction during the three battery charging cycles. The uncertified LCUs BS 300 (R2=0.87), 1 Sec (R2=0.60), and LED curing light (R2=0.83) showed significant power reduction, decreasing the emission spectrum (mW/cm2/nm) at the end of the battery charging cycle. The light distribution on the active tip across the level battery was modified significantly with successive exposure times.

Conclusions: The certified LCUs (VALO Grand, Radii Xpert, and LED.B) and uncertified LCU (VAFU), maintained power, emission spectrum, and light distributions during the tested battery life cycles. Low-cost certified LCU LED.B exhibited inhomogeneous light concentrated at the center of the tip. Low-cost uncertified LCUs-BS 300, 1 Sec, and LED curing light-had significant power reductions during the battery cycles and increased inhomogeneous light distribution along the successive exposure times.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
连续充电过程中的电池电量对电子商务上的认证和低成本未认证光固化设备性能的影响。
目的评估电池电量对功率(毫瓦)、发射光谱(毫瓦/平方厘米/纳米)以及通过电子商务购买的经认证(FDA/ANVISA)和未经认证的低成本光固化装置(LCUs)的光分布(毫瓦/平方厘米)的影响:方法:七台 LCU,三台通过认证:VALO Grand (Ultradent); Radii Xpert (SDI); and LED.B (Woodpecker); and four uncertified:1 Sec、BS 300、LED 固化灯和 VAFU(VRN,AZDENT)。评估 LCU 的方法是,在三个电池充电周期内使用积分球计算每个 20 秒的连续五个曝光周期后的功率(毫瓦)以及初始和最终周期的发射光谱(毫瓦/平方厘米/纳米)。在电池完全放电之前,每进行 50 次曝光循环后,使用光束轮廓分析检查 LCU 顶端的光分布情况。数据通过功率与曝光次数(R2)之间的线性回归进行分析:结果:经过认证的 LCU VALO Grand(R2=0.005)、LED.B(R2=0.02)和 Radii Xpert(R2=0.09)以及未经认证的 LCU VAFU(R2=0.002)在三个电池充电周期内功率没有明显下降。未经认证的 LCU BS 300(R2=0.87)、1 Sec(R2=0.60)和 LED 固化灯(R2=0.83)显示出明显的功率下降,在电池充电周期结束时发射光谱(毫瓦/平方厘米/纳米)下降。随着连续曝光时间的延长,整个水平电池上有源尖端的光分布发生了显著变化:结论:经过认证的 LCU(VALO Grand、Radii Xpert 和 LED.B)和未经认证的 LCU(VAFU)在测试的电池寿命周期内保持了功率、发射光谱和光分布。经认证的低成本 LCU LED.B 显示出不均匀的光线集中在顶端中心。低成本、未经认证的 LCU--BS 300、1 Sec 和 LED 固化灯--在电池寿命周期内功率显著降低,并且在连续曝光时间内不均匀光分布增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Operative dentistry
Operative dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
9.10%
发文量
124
审稿时长
6-12 weeks
期刊介绍: Operative Dentistry is a refereed, international journal published bi-monthly and distributed to subscribers in over 50 countries. In 2012, we printed 84 articles (672 pages). Papers were submitted by authors from 45 countries, in the categories of Clinical Research, Laboratory Research, Clinical Techniques/Case Presentations and Invited Papers, as well as Editorials and Abstracts. One of the strong points of our journal is that our current publication time for accepted manuscripts is 4 to 6 months from the date of submission. Clinical Techniques/Case Presentations have a very quick turnaround time, which allows for very rapid publication of clinical based concepts. We also provide color for those papers that would benefit from its use. The journal does not accept any advertising but you will find postings for faculty positions. Additionally, the journal also does not rent, sell or otherwise allow its subscriber list to be used by any other entity
期刊最新文献
3D Printed Dual Reduction Guide: A Feasible Alternative for Conservative Gingivectomy and Minimally Invasive Preparation for Ceramic Veneers. A Novel Isolation Technique Using Polytetrafluoroethylene Tape and Split Dam Isolation for Cementation in Bridge Restorations. Bacterial Adhesion and In Situ Biodegradation of Preheated Resin Composite Used as a Luting Agent for Indirect Restorations. Biomechanical and Physical Characteristics of Dental Dam Sheets Used for Absolute Isolation. Bonding and Cleaning Effects of Irrigation Protocols Using Calcium Hypochlorite on the Post-space Radicular Dentin.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1