Optimizing the safety and efficacy of the awake venovenous extracorporeal membrane oxygenation in patients with COVID-19-related ARDS.

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC ACS Applied Electronic Materials Pub Date : 2024-01-01 DOI:10.1177/17534666241282590
Peter Sklienka, Filip Burša, Michal Frelich, Jan Máca, Vojtech Vodička, Hana Straková, Markéta Bílená, Tereza Romanová, Hana Tomášková
{"title":"Optimizing the safety and efficacy of the awake venovenous extracorporeal membrane oxygenation in patients with COVID-19-related ARDS.","authors":"Peter Sklienka, Filip Burša, Michal Frelich, Jan Máca, Vojtech Vodička, Hana Straková, Markéta Bílená, Tereza Romanová, Hana Tomášková","doi":"10.1177/17534666241282590","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Maintaining the patient awake and not intubated during the venovenous extracorporeal membrane oxygenation (VV ECMO) reduces the risk of ventilation-induced lung injury in patients with ARDS. Currently, there is a lack of data on outcomes and complications associated with the awake ECMO approach.</p><p><strong>Objectives: </strong>To evaluate outcomes and the occurrence of complications of awake ECMO approach guided by local safety protocol comprising ultrasound-guided cannulation, argatroban-based anticoagulation, respiratory support, and routine sedation targeted to reduce respiratory effort and keeping nurse-to-patient ratio of 1:1.</p><p><strong>Design: </strong>A single-center retrospective case series analysis.</p><p><strong>Methods: </strong>Consecutive patients with COVID-19-related acute respiratory distress syndrome (ARDS) (CARDS) treated by full awake VV ECMO approach from April 2019 to December 2023 were eligible.</p><p><strong>Results: </strong>Our center treated 10 patients (mean age 54.7 ± 11.6 years) with CARDS with an awake ECMO approach. The reasons for awake ECMO included the presence of barotrauma in six patients, a team consensus to prefer awake ECMO instead of mechanical ventilation in three patients, and the patient's refusal to be intubated in one case. Before ECMO, patients were severely hypoxemic, with a mean value of Horowitz index of 48.9 ± 9.1 mmHg and a mean respiratory rate of 28.8 ± 7.3 breaths per minute on high-flow nasal cannula or noninvasive ventilation support. The mean duration of awake VV ECMO was 558.0 ± 173.6 h. Seven patients (70%) were successfully disconnected from ECMO and fully recovered. Intubation from respiratory causes was needed in three patients (30%), all of whom died eventually. In total, three episodes of delirium, two episodes of significant bleeding, one pneumothorax requiring chest tube insertion, and one oxygenator acute exchange occurred throughout the 5580 h of awake ECMO. No complications related to cannula displacement or malposition occurred.</p><p><strong>Conclusion: </strong>The awake ECMO strategy guided by safety protocol appears to be a safe approach in conscious, severely hypoxemic, non-intubated patients with COVID-19-related ARDS.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11489919/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17534666241282590","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Maintaining the patient awake and not intubated during the venovenous extracorporeal membrane oxygenation (VV ECMO) reduces the risk of ventilation-induced lung injury in patients with ARDS. Currently, there is a lack of data on outcomes and complications associated with the awake ECMO approach.

Objectives: To evaluate outcomes and the occurrence of complications of awake ECMO approach guided by local safety protocol comprising ultrasound-guided cannulation, argatroban-based anticoagulation, respiratory support, and routine sedation targeted to reduce respiratory effort and keeping nurse-to-patient ratio of 1:1.

Design: A single-center retrospective case series analysis.

Methods: Consecutive patients with COVID-19-related acute respiratory distress syndrome (ARDS) (CARDS) treated by full awake VV ECMO approach from April 2019 to December 2023 were eligible.

Results: Our center treated 10 patients (mean age 54.7 ± 11.6 years) with CARDS with an awake ECMO approach. The reasons for awake ECMO included the presence of barotrauma in six patients, a team consensus to prefer awake ECMO instead of mechanical ventilation in three patients, and the patient's refusal to be intubated in one case. Before ECMO, patients were severely hypoxemic, with a mean value of Horowitz index of 48.9 ± 9.1 mmHg and a mean respiratory rate of 28.8 ± 7.3 breaths per minute on high-flow nasal cannula or noninvasive ventilation support. The mean duration of awake VV ECMO was 558.0 ± 173.6 h. Seven patients (70%) were successfully disconnected from ECMO and fully recovered. Intubation from respiratory causes was needed in three patients (30%), all of whom died eventually. In total, three episodes of delirium, two episodes of significant bleeding, one pneumothorax requiring chest tube insertion, and one oxygenator acute exchange occurred throughout the 5580 h of awake ECMO. No complications related to cannula displacement or malposition occurred.

Conclusion: The awake ECMO strategy guided by safety protocol appears to be a safe approach in conscious, severely hypoxemic, non-intubated patients with COVID-19-related ARDS.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
优化 COVID-19 相关 ARDS 患者清醒状态下静脉体外膜氧合的安全性和有效性。
背景:在静脉体外膜氧合(VV ECMO)过程中保持患者清醒且不插管可降低 ARDS 患者通气诱发肺损伤的风险。目前,缺乏与清醒 ECMO 方法相关的疗效和并发症的数据:目的:评估在当地安全方案(包括超声引导插管、阿加曲班抗凝、呼吸支持、常规镇静以降低呼吸强度并保持护士与患者的比例为 1:1)指导下进行清醒 ECMO 的疗效和并发症发生情况:设计:单中心回顾性病例系列分析:2019年4月至2023年12月期间连续接受全清醒VV ECMO方法治疗的COVID-19相关急性呼吸窘迫综合征(ARDS)(CARDS)患者:本中心采用清醒 ECMO 法治疗了 10 例 CARDS 患者(平均年龄为 54.7 ± 11.6 岁)。采用清醒 ECMO 的原因包括:6 例患者存在气压创伤;3 例患者团队一致同意采用清醒 ECMO 代替机械通气;1 例患者拒绝插管。ECMO 前,患者严重低氧血症,霍洛维茨指数(Horowitz index)平均值为 48.9 ± 9.1 mmHg,高流量鼻插管或无创通气支持下的平均呼吸频率为 28.8 ± 7.3 次/分钟。七名患者(70%)成功脱离 ECMO 并完全康复。三名患者(30%)因呼吸系统原因需要插管,最终全部死亡。在 5580 小时的清醒 ECMO 过程中,总共发生了 3 次谵妄、2 次大量出血、1 次需要插入胸管的气胸和 1 次氧合器急性交换。没有发生与插管移位或错位有关的并发症:结论:对于意识清醒、严重低氧血症、未插管的 COVID-19 相关 ARDS 患者,在安全协议指导下的清醒 ECMO 策略似乎是一种安全的方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
期刊最新文献
Hyperbaric oxygen treatment promotes tendon-bone interface healing in a rabbit model of rotator cuff tears. Oxygen-ozone therapy for myocardial ischemic stroke and cardiovascular disorders. Comparative study on the anti-inflammatory and protective effects of different oxygen therapy regimens on lipopolysaccharide-induced acute lung injury in mice. Heme oxygenase/carbon monoxide system and development of the heart. Hyperbaric oxygen for moderate-to-severe traumatic brain injury: outcomes 5-8 years after injury.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1