Resorption characteristics of an open architecture biocomposite interference screw after ACL reconstruction

IF 2 Q2 ORTHOPEDICS Journal of Experimental Orthopaedics Pub Date : 2024-10-21 DOI:10.1002/jeo2.70016
Martin Lind, Torsten Grønbech Nielsen, Flemming K. Nielsen, Ole G. Sørensen, Bjarne Mygind-Klavsen, Peter Faunø
{"title":"Resorption characteristics of an open architecture biocomposite interference screw after ACL reconstruction","authors":"Martin Lind,&nbsp;Torsten Grønbech Nielsen,&nbsp;Flemming K. Nielsen,&nbsp;Ole G. Sørensen,&nbsp;Bjarne Mygind-Klavsen,&nbsp;Peter Faunø","doi":"10.1002/jeo2.70016","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Purpose</h3>\n \n <p>Absorbable interference screws for anterior cruciate ligament reconstruction (ACLR) can lead to tunnel widening and cyst formation. The Biosure Regenesorb interference screw (Smith &amp; Nephew). has been developed with an optimised calcium phosphate/polymer composition to promote bone formation during resorption. The present study aims to investigate screw resorption, new bone formation, and tunnel geometry following ACLR with Biosure Regenesorb screw tibial fixation.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The study is a prospective single-centre case series of 12 patients with ACL lesions and treated with ACLR using hamstring tendon autograft with Biosure Regenesorb interference screw tibial fixation with a two-year follow-up period. The Biosure Regenesorb consists of 65% polylactide-glycolic acid poly. 20% calcium sulphate and 15% tricalcium phosphate. Primary endpoint: Tunnel volume. implant volume and new bone formation in the tibial tunnel is evaluated by quantitative computed tomography (CT) scanning. Secondary endpoints: Arthrometric knee laxity, International Knee Documentation Committee (IKDC) and Knee Osteoarthritis and Injury Outcome Scores (KOOS) and Tegner activity scale.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Screw volume decreased to 44% within the two-year follow-up period while tunnel volume remained unchanged. Only a minor amount (&lt;1% of tunnel volume) of new bone formation in the screw remnants was observed. Sagittal knee laxity at one year was 0.9 mm. The IKDC score increased by 15 points and the KOOS sport and KOOS quality of life scores increased by 25 and 26 points. respectively.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>ACLR using Biosure Regenesorb interference screw does not result in tunnel widening. showing a screw resorption of 44% after two years and minor new bone formation. Knee stability and subjective outcome improvements are as expected after other ACLR methods.</p>\n </section>\n \n <section>\n \n <h3> Level of evidence</h3>\n \n <p>IV.</p>\n </section>\n </div>","PeriodicalId":36909,"journal":{"name":"Journal of Experimental Orthopaedics","volume":"11 4","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2024-10-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11491983/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Experimental Orthopaedics","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jeo2.70016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

Absorbable interference screws for anterior cruciate ligament reconstruction (ACLR) can lead to tunnel widening and cyst formation. The Biosure Regenesorb interference screw (Smith & Nephew). has been developed with an optimised calcium phosphate/polymer composition to promote bone formation during resorption. The present study aims to investigate screw resorption, new bone formation, and tunnel geometry following ACLR with Biosure Regenesorb screw tibial fixation.

Methods

The study is a prospective single-centre case series of 12 patients with ACL lesions and treated with ACLR using hamstring tendon autograft with Biosure Regenesorb interference screw tibial fixation with a two-year follow-up period. The Biosure Regenesorb consists of 65% polylactide-glycolic acid poly. 20% calcium sulphate and 15% tricalcium phosphate. Primary endpoint: Tunnel volume. implant volume and new bone formation in the tibial tunnel is evaluated by quantitative computed tomography (CT) scanning. Secondary endpoints: Arthrometric knee laxity, International Knee Documentation Committee (IKDC) and Knee Osteoarthritis and Injury Outcome Scores (KOOS) and Tegner activity scale.

Results

Screw volume decreased to 44% within the two-year follow-up period while tunnel volume remained unchanged. Only a minor amount (<1% of tunnel volume) of new bone formation in the screw remnants was observed. Sagittal knee laxity at one year was 0.9 mm. The IKDC score increased by 15 points and the KOOS sport and KOOS quality of life scores increased by 25 and 26 points. respectively.

Conclusion

ACLR using Biosure Regenesorb interference screw does not result in tunnel widening. showing a screw resorption of 44% after two years and minor new bone formation. Knee stability and subjective outcome improvements are as expected after other ACLR methods.

Level of evidence

IV.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
前交叉韧带重建术后开放结构生物复合干扰螺钉的吸收特性。
目的:用于前交叉韧带重建(ACLR)的可吸收干扰螺钉可能导致隧道增宽和囊肿形成。Biosure Regenesorb 干扰螺钉(Smith & Nephew)采用优化的磷酸钙/聚合物成分,可在吸收过程中促进骨形成。本研究旨在调查使用 Biosure Regenesorb 螺钉胫骨固定进行 ACLR 后的螺钉吸收、新骨形成和隧道几何形状:本研究是一项前瞻性单中心病例系列研究,共收集了 12 例前交叉韧带损伤患者的病例,采用腘绳肌腱自体移植和 Biosure Regenesorb 干扰螺钉胫骨固定进行前交叉韧带重建治疗,随访两年。Biosure Regenesorb 由 65% 的聚乳酸-乙醇酸聚酯、20% 的硫酸钙和 15% 的聚丙烯组成。20% 的硫酸钙和 15% 的磷酸三钙。主要终点通过定量计算机断层扫描(CT)评估隧道体积、植入物体积和胫骨隧道内新骨形成情况。次要终点:关节测量膝关节松弛度、国际膝关节文献委员会(IKDC)和膝关节骨关节炎与损伤结果评分(KOOS)以及 Tegner 活动量表:结果:在两年的随访期内,螺钉量减少了44%,而隧道量保持不变。结果:在两年的随访期内,螺钉体积减少了 44%,而隧道体积保持不变:使用 Biosure Regenesorb 干扰螺钉进行 ACLR 不会导致隧道增宽,两年后螺钉吸收了 44%,只有少量新骨形成。膝关节稳定性和主观结果的改善与其他 ACLR 方法的预期相同:证据等级:IV。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Experimental Orthopaedics
Journal of Experimental Orthopaedics Medicine-Orthopedics and Sports Medicine
CiteScore
3.20
自引率
5.60%
发文量
114
审稿时长
13 weeks
期刊最新文献
Translation and cross-cultural adaptation to Spanish of the Anterior Cruciate Ligament Return to Sport after Injury Scale (SP ACL‑RSI): Measurement properties and responsiveness in a multisport sample Machine learning in knee injury sequelae detection: Unravelling the role of psychological factors and preventing long-term sequelae Anteroposterior axis of the tibia for kinematic aligned total knee arthroplasty Radiographic acceptable zone of endobutton placement in ACL reconstruction: A prospective study Does free tendon length influence the injury risk of the Achilles tendon? A finite element study
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1