{"title":"[A case of amyotrophic lateral sclerosis managed by tracheostomy and invasive ventilation in which air leaks occurred at the cuff].","authors":"Nobuhiko Shibasaki, Kaoru Konishi, Yutaka Nishiyama, Tetsuo Miyagawa, Takaya Numayama","doi":"10.5692/clinicalneurol.cn-001990","DOIUrl":null,"url":null,"abstract":"<p><p>The patient was a 64-year-old woman who had been diagnosed with amyotrophic lateral sclerosis 8 years ago, and had been under artificial ventilation with tracheotomy for 6 years. Computed tomography indicated a dilated tracheal diameter of 29.6 mm at the cuff, and a high cuff pressure of 80 cmH<sub>2</sub>O. An adjustable flange tracheostomy tube with an optional length setting was used to extend the effective length by 28 mm. A previously evident air leak disappeared with the change in cuff level, and cuff pressure decreased to 25 cmH<sub>2</sub>O. X-ray images indicated a reduction in the size of the previous cuff area. Tracheal dilatation due to improper management of cuff pressure is a contributing factor to air leakage at the cuff area, and using an adjustable flange tracheostomy tube in an effort to resolve such air leaks is a valid option.</p>","PeriodicalId":39292,"journal":{"name":"Clinical Neurology","volume":" ","pages":"789-793"},"PeriodicalIF":0.0000,"publicationDate":"2024-11-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Neurology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5692/clinicalneurol.cn-001990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/19 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
The patient was a 64-year-old woman who had been diagnosed with amyotrophic lateral sclerosis 8 years ago, and had been under artificial ventilation with tracheotomy for 6 years. Computed tomography indicated a dilated tracheal diameter of 29.6 mm at the cuff, and a high cuff pressure of 80 cmH2O. An adjustable flange tracheostomy tube with an optional length setting was used to extend the effective length by 28 mm. A previously evident air leak disappeared with the change in cuff level, and cuff pressure decreased to 25 cmH2O. X-ray images indicated a reduction in the size of the previous cuff area. Tracheal dilatation due to improper management of cuff pressure is a contributing factor to air leakage at the cuff area, and using an adjustable flange tracheostomy tube in an effort to resolve such air leaks is a valid option.