Transcarotid flow reversal for proximal control during cerebral aneurysm clip reconstruction: illustrative case.

Nicole M Wenger, Matthew Hentschel, Ting I Wang, Kevin T Kim, Nicholas Caffes, Jacob Cherian
{"title":"Transcarotid flow reversal for proximal control during cerebral aneurysm clip reconstruction: illustrative case.","authors":"Nicole M Wenger, Matthew Hentschel, Ting I Wang, Kevin T Kim, Nicholas Caffes, Jacob Cherian","doi":"10.3171/CASE24330","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Paraclinoid aneurysms can pose an operative challenge during clip reconstruction, given the complex surrounding anatomy and the aneurysmal tendency to maintain turgor despite standard approaches to proximal control. This report demonstrates the use of intraoperative retrograde arteriovenous shunting with the transcarotid artery revascularization (TCAR) system to assist in the safe clip reconstruction of an irregular paraclinoid aneurysm.</p><p><strong>Observations: </strong>A 33-year-old woman presented with perimesencephalic subarachnoid hemorrhage and was found to have an incidental 9-mm ophthalmic aneurysm. Coil embolization was not successful. During microsurgical clip reconstruction, the left common carotid artery was exposed to allow for proximal control as well as transcarotid arterial sheath placement. Flow reversal was instituted throughout the aneurysm dissection and clipping, with a visible softening of the aneurysm. Intraoperative angiography confirming successful clip reconstruction was performed utilizing the TCAR sheath. The case was complicated by the development of cerebrospinal fluid rhinorrhea postoperatively, requiring surgical repair. The patient has since made a complete recovery.</p><p><strong>Lessons: </strong>Transcarotid flow reversal utilizing the TCAR system has potential for use in the surgical treatment of paraclinoid aneurysms, as it may aid in softening the aneurysm for safer dissection and clip reconstruction, protect against aneurysm-associated emboli, and provide an avenue for intraoperative angiography. https://thejns.org/doi/10.3171/CASE24330.</p>","PeriodicalId":94098,"journal":{"name":"Journal of neurosurgery. Case lessons","volume":"8 16","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11488372/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neurosurgery. Case lessons","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3171/CASE24330","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Paraclinoid aneurysms can pose an operative challenge during clip reconstruction, given the complex surrounding anatomy and the aneurysmal tendency to maintain turgor despite standard approaches to proximal control. This report demonstrates the use of intraoperative retrograde arteriovenous shunting with the transcarotid artery revascularization (TCAR) system to assist in the safe clip reconstruction of an irregular paraclinoid aneurysm.

Observations: A 33-year-old woman presented with perimesencephalic subarachnoid hemorrhage and was found to have an incidental 9-mm ophthalmic aneurysm. Coil embolization was not successful. During microsurgical clip reconstruction, the left common carotid artery was exposed to allow for proximal control as well as transcarotid arterial sheath placement. Flow reversal was instituted throughout the aneurysm dissection and clipping, with a visible softening of the aneurysm. Intraoperative angiography confirming successful clip reconstruction was performed utilizing the TCAR sheath. The case was complicated by the development of cerebrospinal fluid rhinorrhea postoperatively, requiring surgical repair. The patient has since made a complete recovery.

Lessons: Transcarotid flow reversal utilizing the TCAR system has potential for use in the surgical treatment of paraclinoid aneurysms, as it may aid in softening the aneurysm for safer dissection and clip reconstruction, protect against aneurysm-associated emboli, and provide an avenue for intraoperative angiography. https://thejns.org/doi/10.3171/CASE24330.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
经颈动脉血流逆转用于脑动脉瘤夹重建过程中的近端控制:示例病例。
背景:副夹层动脉瘤周围解剖结构复杂,尽管采用了标准的近端控制方法,但动脉瘤仍有保持充盈的趋势,因此在夹层重建过程中,副夹层动脉瘤可能会给手术带来挑战。本报告展示了使用经颈动脉再血管化(TCAR)系统进行术中逆行动静脉分流,以协助安全夹重建不规则的蛛网膜旁动脉瘤:一名 33 岁的女性因脑周蛛网膜下腔出血就诊,意外发现她患有 9 毫米的眼动脉瘤。线圈栓塞术没有成功。在显微手术夹重建过程中,暴露了左侧颈总动脉,以便进行近端控制和经颈动脉鞘置入。在动脉瘤剥离和夹闭的整个过程中都进行了血流逆转,动脉瘤明显变软。术中血管造影证实,利用 TCAR 鞘成功进行了夹子重建。术后出现脑脊液鼻出血,需要进行手术修补,使病例变得复杂。患者现已完全康复:https://thejns.org/doi/10.3171/CASE24330。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
0
期刊最新文献
Convexity dural hemangioma: illustrative case. Detection of face motor activation in the precentral gyrus with functional thermography following inconclusive direct electrical stimulation mapping: illustrative case. Endovascular removal of a symptomatic intracranial foreign body via contact aspiration: illustrative case. Failed ulnar nerve surgery due to persistent unrecognized snapping triceps from cubitus varus due to a distal humeral malunion in an adult: illustrative case. Middle fossa approach for a petrous apex bony spur causing trigeminal neuralgia: illustrative case.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1