Cuff tear of endotracheal tube induced by a palatal orthodontic device during nasotracheal intubation: a case report.

Kyung Nam Park, Seung-Hwa Ryoo, Kwang-Suk Seo, Hyun Jeong Kim, Myong-Hwan Karm
{"title":"Cuff tear of endotracheal tube induced by a palatal orthodontic device during nasotracheal intubation: a case report.","authors":"Kyung Nam Park, Seung-Hwa Ryoo, Kwang-Suk Seo, Hyun Jeong Kim, Myong-Hwan Karm","doi":"10.17245/jdapm.2024.24.5.361","DOIUrl":null,"url":null,"abstract":"<p><p>Orthognathic surgery often requires intraoral orthodontic appliances that are fixed directly to the bone, which can complicate nasotracheal intubation if the devices protrude into the nasal cavity. This case report describes a 19-year-old man scheduled for elective orthognathic surgery who experienced recurrent cuff tears of the endotracheal tube during nasotracheal intubation due to protruding orthodontic screws in the palate. Despite initial attempts at nasotracheal intubation through the left nostril, the cuff of the 7.0 mm internal diameter (ID) Ring, Adair & Elwyn (RAE) tube repeatedly ruptured, with identical rupture patterns observed. Facial CT revealed that the orthodontic screws had protruded into both nasal cavities with significant visibility in the sagittal, coronal, and transverse views. Fiberoptic examination of the left nasal passage identified a firm protrusion below the inferior turbinate, corresponding to the location of the screw, which likely caused the cuff tears. Intubation was successfully performed via the right nostril during the fiberoptic examination. This case highlights the critical importance of evaluating intraoral corrective devices using comprehensive craniofacial imaging before anesthesia induction, as well as conducting fiberoptic examinations during intubation to avoid complications and ensure patient safety.</p>","PeriodicalId":94330,"journal":{"name":"Journal of dental anesthesia and pain medicine","volume":"24 5","pages":"361-366"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11471342/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental anesthesia and pain medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17245/jdapm.2024.24.5.361","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/26 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Orthognathic surgery often requires intraoral orthodontic appliances that are fixed directly to the bone, which can complicate nasotracheal intubation if the devices protrude into the nasal cavity. This case report describes a 19-year-old man scheduled for elective orthognathic surgery who experienced recurrent cuff tears of the endotracheal tube during nasotracheal intubation due to protruding orthodontic screws in the palate. Despite initial attempts at nasotracheal intubation through the left nostril, the cuff of the 7.0 mm internal diameter (ID) Ring, Adair & Elwyn (RAE) tube repeatedly ruptured, with identical rupture patterns observed. Facial CT revealed that the orthodontic screws had protruded into both nasal cavities with significant visibility in the sagittal, coronal, and transverse views. Fiberoptic examination of the left nasal passage identified a firm protrusion below the inferior turbinate, corresponding to the location of the screw, which likely caused the cuff tears. Intubation was successfully performed via the right nostril during the fiberoptic examination. This case highlights the critical importance of evaluating intraoral corrective devices using comprehensive craniofacial imaging before anesthesia induction, as well as conducting fiberoptic examinations during intubation to avoid complications and ensure patient safety.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在鼻气管插管过程中,腭矫形器诱发气管导管袖口撕裂:病例报告。
正颌手术通常需要将口内正畸装置直接固定在骨头上,如果这些装置突出到鼻腔内,就会使鼻气管插管复杂化。本病例报告描述了一名计划接受择期正颌手术的 19 岁男子,在鼻气管插管过程中,由于正畸螺钉突出于腭部,导致气管导管袖口反复撕裂。尽管最初尝试了从左鼻孔进行鼻气管插管,但内径为 7.0 毫米的 Ring, Adair & Elwyn(RAE)气管插管的充气罩囊反复破裂,且破裂形态完全相同。面部 CT 显示,正畸螺钉已突出到两个鼻腔,在矢状、冠状和横切面上都有明显的可见度。左侧鼻腔的纤支镜检查发现,下鼻甲下方有一个坚硬的突出物,与螺钉的位置相对应,这很可能是造成袖带撕裂的原因。在纤支镜检查过程中,通过右鼻孔成功进行了插管。本病例强调了在麻醉诱导前使用全面的颅面部成像评估口内矫正装置以及在插管时进行纤支镜检查以避免并发症和确保患者安全的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analgesic efficiency of dexketoprofen trometamol in third molar surgery: a systematic review and meta-analysis. Assessment of the effect of premedication on the success of inferior alveolar nerve block in tobacco chewing patients with symptomatic irreversible pulpitis: a randomized control trial. Cuff tear of endotracheal tube induced by a palatal orthodontic device during nasotracheal intubation: a case report. Eye movement desensitization and reprocessing therapy as an adjunct to pain management during dental extraction in children - a randomized control trial. Photobiomodulation by soft laser irradiation with and without ibuprofen improves success rate of inferior alveolar nerve block using 2% lignocaine with adrenaline in symptomatic irreversible pulpitis of mandibular molar teeth: a double-blind, randomized placebo-controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1