Efficacy and safety of a novel vena cava filter on pulmonary embolism prophylaxis: a prospective, multicenter, randomized, parallel, positive-controlled, noninferiority clinical trial.

IF 2.9 2区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Quantitative Imaging in Medicine and Surgery Pub Date : 2024-10-01 Epub Date: 2024-09-14 DOI:10.21037/qims-24-879
Maofeng Gong, Boxiang Zhao, Jianlong Liu, Gaojun Teng, Caifang Ni, Hao Xu, Zhen Li, Shuiting Zhai, Yanrong Zhang, Hua Xiang, Weizhu Yang, Jianping Gu
{"title":"Efficacy and safety of a novel vena cava filter on pulmonary embolism prophylaxis: a prospective, multicenter, randomized, parallel, positive-controlled, noninferiority clinical trial.","authors":"Maofeng Gong, Boxiang Zhao, Jianlong Liu, Gaojun Teng, Caifang Ni, Hao Xu, Zhen Li, Shuiting Zhai, Yanrong Zhang, Hua Xiang, Weizhu Yang, Jianping Gu","doi":"10.21037/qims-24-879","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>There are different types of vena cava filter (VCF) available in clinical practice. However, limited data exist to determine whether one type is superior to another, and no single VCF is universally recommended in clinical guidelines. The objective of this study was to investigate the safety and efficacy of a novel VCF, Octoparms, for the prevention of pulmonary embolism (PE) and to compare it with the Celect filter.</p><p><strong>Methods: </strong>This multicenter, randomized, open-label, parallel, positive-controlled, noninferiority trial was conducted in 10 centers across 6 provinces in China from October 2017 to March 2019. Patients who had confirmed lower extremity deep vein thrombosis or PE or who were at risk of PE with a clinical indication for VCF placement due to contraindication to or failure of anticoagulant therapy were included in the trial. The sample size for this trial was based on the assumption that the clinical success rate would be 95% and the noninferiority margin would be 10% for both filters. Each patient underwent baseline testing and was randomized using a web-based central system. Any additional interventions or standard treatments patients received along with the VCF placement were recorded. The primary endpoint was the overall clinical success rate, including technical and clinical success of filter placement and retrieval. The secondary endpoint was the safety of filter placement and retrieval, encompassing procedure-related and filter-related complications.</p><p><strong>Results: </strong>A total of 188 patients were included and were divided into two groups: the Octoparms group (n=94) and the Celect group (n=94). Baseline characteristics and demographics were comparable between the two groups (P>0.05). Technical and clinical success rates for filter placement were achieved in 100% (188/188) of patients. The median dwelling time was 12.0 days (range, 4-190 days). Ten VCFs were left <i>in situ</i> as permanent devices. Of the remaining 178 patients, technical success and clinical success rates for filter retrieval were both achieved in 100% of cases (178/178). Clinical success rates were 92.6% (87/94) for the Octoparms group and 96.8% (91/94) for the Celect group, with a difference of -4.2% (hazard ratio 2.441, 95% confidence interval 0.612-9.741; P=0.206). The lower limit was greater than the noninferiority margin of -10%. Eight patients experienced a total of eight procedure-related complications. No filter-related complications, such as migration, deformation, inferior vena cava (IVC) penetration, peripheral organ damage, or IVC stenosis/occlusion, were observed (P>0.05).</p><p><strong>Conclusions: </strong>The Octoparms filter exhibited a high rate of clinical success and a low rate of complications during placement and retrieval, demonstrating noninferiority to the Celect filter.</p>","PeriodicalId":54267,"journal":{"name":"Quantitative Imaging in Medicine and Surgery","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11485371/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Quantitative Imaging in Medicine and Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21037/qims-24-879","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: There are different types of vena cava filter (VCF) available in clinical practice. However, limited data exist to determine whether one type is superior to another, and no single VCF is universally recommended in clinical guidelines. The objective of this study was to investigate the safety and efficacy of a novel VCF, Octoparms, for the prevention of pulmonary embolism (PE) and to compare it with the Celect filter.

Methods: This multicenter, randomized, open-label, parallel, positive-controlled, noninferiority trial was conducted in 10 centers across 6 provinces in China from October 2017 to March 2019. Patients who had confirmed lower extremity deep vein thrombosis or PE or who were at risk of PE with a clinical indication for VCF placement due to contraindication to or failure of anticoagulant therapy were included in the trial. The sample size for this trial was based on the assumption that the clinical success rate would be 95% and the noninferiority margin would be 10% for both filters. Each patient underwent baseline testing and was randomized using a web-based central system. Any additional interventions or standard treatments patients received along with the VCF placement were recorded. The primary endpoint was the overall clinical success rate, including technical and clinical success of filter placement and retrieval. The secondary endpoint was the safety of filter placement and retrieval, encompassing procedure-related and filter-related complications.

Results: A total of 188 patients were included and were divided into two groups: the Octoparms group (n=94) and the Celect group (n=94). Baseline characteristics and demographics were comparable between the two groups (P>0.05). Technical and clinical success rates for filter placement were achieved in 100% (188/188) of patients. The median dwelling time was 12.0 days (range, 4-190 days). Ten VCFs were left in situ as permanent devices. Of the remaining 178 patients, technical success and clinical success rates for filter retrieval were both achieved in 100% of cases (178/178). Clinical success rates were 92.6% (87/94) for the Octoparms group and 96.8% (91/94) for the Celect group, with a difference of -4.2% (hazard ratio 2.441, 95% confidence interval 0.612-9.741; P=0.206). The lower limit was greater than the noninferiority margin of -10%. Eight patients experienced a total of eight procedure-related complications. No filter-related complications, such as migration, deformation, inferior vena cava (IVC) penetration, peripheral organ damage, or IVC stenosis/occlusion, were observed (P>0.05).

Conclusions: The Octoparms filter exhibited a high rate of clinical success and a low rate of complications during placement and retrieval, demonstrating noninferiority to the Celect filter.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
新型腔静脉过滤器预防肺栓塞的有效性和安全性:一项前瞻性、多中心、随机、平行、阳性对照、非劣效性临床试验。
背景:临床上有多种不同类型的腔静脉过滤器(VCF)。然而,能确定一种类型是否优于另一种类型的数据十分有限,临床指南中也没有普遍推荐任何一种腔静脉过滤器。本研究旨在探讨新型腔静脉过滤器 Octoparms 用于预防肺栓塞(PE)的安全性和有效性,并将其与 Celect 过滤器进行比较:这项多中心、随机、开放标签、平行、阳性对照、非劣效试验于2017年10月至2019年3月在中国6个省的10个中心进行。试验纳入了确诊为下肢深静脉血栓或PE的患者,或因禁忌抗凝治疗或抗凝治疗失败而有PE风险且有VCF置入临床指征的患者。该试验的样本量是根据两种滤器的临床成功率均为 95% 和非劣效性差值均为 10% 的假设确定的。每位患者都接受了基线测试,并通过网络中央系统进行了随机分组。患者在植入 VCF 的同时接受的任何额外干预或标准治疗均被记录在案。主要终点是总体临床成功率,包括过滤器置入和取出的技术和临床成功率。次要终点是过滤器置入和取出的安全性,包括手术相关并发症和过滤器相关并发症:共纳入 188 名患者,分为两组:Octoparms 组(94 人)和 Celect 组(94 人)。两组患者的基线特征和人口统计学具有可比性(P>0.05)。100%(188/188)的患者在技术和临床上成功置入过滤器。中位停留时间为 12.0 天(4-190 天不等)。10个VCF作为永久性装置留在原位。在剩余的 178 例患者中,100% 的病例(178/178)都实现了过滤器取出的技术成功率和临床成功率。Octoparms 组的临床成功率为 92.6%(87/94),Celect 组为 96.8%(91/94),差异为-4.2%(危险比 2.441,95% 置信区间 0.612-9.741;P=0.206)。下限大于-10%的非劣效边际。八名患者共经历了八次手术相关并发症。未观察到过滤器相关并发症,如移位、变形、下腔静脉(IVC)穿透、外周器官损伤或 IVC 狭窄/闭塞(P>0.05):结论:Octoparms 过滤器的临床成功率高,置入和取出过程中的并发症发生率低,与 Celect 过滤器相比并无劣势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Quantitative Imaging in Medicine and Surgery
Quantitative Imaging in Medicine and Surgery Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
4.20
自引率
17.90%
发文量
252
期刊介绍: Information not localized
期刊最新文献
Comparison of single shot and multishot diffusion-weighted imaging in 5-T magnetic resonance imaging for brain disease diagnosis. Complications of synchronous microwave ablation and biopsy versus microwave ablation alone for pulmonary sub-solid nodules: a retrospective, large sample, case-control study. Congenital uterine arteriovenous malformation treated by hysterectomy: a description of two cases. Diagnostic value of a magnetic resonance imaging (MRI)-based vertebral bone quality score for bone mineral density assessment: an updated systematic review and meta-analysis. Dilated multi-scale residual attention (DMRA) U-Net: three-dimensional (3D) dilated multi-scale residual attention U-Net for brain tumor segmentation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1