Circumferential Labral Reconstruction With Knotless All-Suture Anchors Restores Hip Distractive Stability: A Cadaveric Biomechanical Analysis.

Ajay C Lall,Benjamin L Smith,Ady H Kahana-Rojkind,Anthony N Khoury,Coen A Wijdicks,Benjamin G Domb
{"title":"Circumferential Labral Reconstruction With Knotless All-Suture Anchors Restores Hip Distractive Stability: A Cadaveric Biomechanical Analysis.","authors":"Ajay C Lall,Benjamin L Smith,Ady H Kahana-Rojkind,Anthony N Khoury,Coen A Wijdicks,Benjamin G Domb","doi":"10.1177/03635465241287146","DOIUrl":null,"url":null,"abstract":"BACKGROUND\r\nThe essential component of managing femoroacetabular impingement involves restoration of the original labral function. Circumferential labral reconstruction (CLR) has shown positive results. However, biomechanical studies of CLR are limited and have not established the efficacy of the modern knotless all-suture anchor (ASA) pull-through technique.\r\n\r\nHYPOTHESES\r\n(1) CLR with knotless ASA fixation will restore native labral suction seal biomechanics; (2) tensioning the ASA to a high-tension state will increase the peak distractive force.\r\n\r\nSTUDY DESIGN\r\nControlled laboratory study.\r\n\r\nMETHODS\r\nEight fresh-frozen human cadaveric hips were dissected free of all soft tissue except the native labrum and transverse acetabular ligament. On an electromechanical testing system, the hips were compressively loaded to 250 N to initiate a suction seal and distracted at a rate of 10 mm/s until rupture of the suction seal. Hips were tested in 4 states: intact labrum, full labral removal, knotless CLR with moderate anchor tension, and CLR with high anchor tension. Peak distractive force (in newtons) was compared using repeated measures analysis of variance (P < .05). Acetabular bevel angles (θ) were measured at labral clockface positions outside the transverse acetabular ligament using a 3-dimensional digitizer stylus after rim preparation. Linear regression plots compared θ and peak distractive force in the CLR state.\r\n\r\nRESULTS\r\nPeak force values were 138.5 ± 13.6 N (mean ± SE) for the intact labrum, 18.4 ± 2.79 N for labral excision, 95.4 ± 23.3 N for moderate-tension CLR, and 126.2 ± 27.3 N for high-tension CLR. Significant differences were observed only when full labral removal was compared with the other conditions: intact (P < .001), moderate-tension CLR (P = .016), and high-tension CLR (P = .002). Steeper acetabular bevel angles (smaller θ) were correlated with greater suction seal restoration (P < .05).\r\n\r\nCONCLUSION\r\nCLR restored distractive stability on average to 82.0% of the intact value after labral deficiency. Retensioning did not significantly increase peak distractive forces.\r\n\r\nCLINICAL RELEVANCE\r\nThese findings provide biomechanical validation supporting CLR using knotless ASAs in an effort to minimize volumetric bone loss and provide other surgical advantages. The prepared rim's bevel angle may be an important variable to optimize for improved suction seal restoration.","PeriodicalId":517411,"journal":{"name":"The American Journal of Sports Medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The American Journal of Sports Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/03635465241287146","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND The essential component of managing femoroacetabular impingement involves restoration of the original labral function. Circumferential labral reconstruction (CLR) has shown positive results. However, biomechanical studies of CLR are limited and have not established the efficacy of the modern knotless all-suture anchor (ASA) pull-through technique. HYPOTHESES (1) CLR with knotless ASA fixation will restore native labral suction seal biomechanics; (2) tensioning the ASA to a high-tension state will increase the peak distractive force. STUDY DESIGN Controlled laboratory study. METHODS Eight fresh-frozen human cadaveric hips were dissected free of all soft tissue except the native labrum and transverse acetabular ligament. On an electromechanical testing system, the hips were compressively loaded to 250 N to initiate a suction seal and distracted at a rate of 10 mm/s until rupture of the suction seal. Hips were tested in 4 states: intact labrum, full labral removal, knotless CLR with moderate anchor tension, and CLR with high anchor tension. Peak distractive force (in newtons) was compared using repeated measures analysis of variance (P < .05). Acetabular bevel angles (θ) were measured at labral clockface positions outside the transverse acetabular ligament using a 3-dimensional digitizer stylus after rim preparation. Linear regression plots compared θ and peak distractive force in the CLR state. RESULTS Peak force values were 138.5 ± 13.6 N (mean ± SE) for the intact labrum, 18.4 ± 2.79 N for labral excision, 95.4 ± 23.3 N for moderate-tension CLR, and 126.2 ± 27.3 N for high-tension CLR. Significant differences were observed only when full labral removal was compared with the other conditions: intact (P < .001), moderate-tension CLR (P = .016), and high-tension CLR (P = .002). Steeper acetabular bevel angles (smaller θ) were correlated with greater suction seal restoration (P < .05). CONCLUSION CLR restored distractive stability on average to 82.0% of the intact value after labral deficiency. Retensioning did not significantly increase peak distractive forces. CLINICAL RELEVANCE These findings provide biomechanical validation supporting CLR using knotless ASAs in an effort to minimize volumetric bone loss and provide other surgical advantages. The prepared rim's bevel angle may be an important variable to optimize for improved suction seal restoration.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用无结全线缝合锚进行环状唇缘重建可恢复髋关节牵张稳定性:尸体生物力学分析。
背景股骨髋臼撞击症治疗的重要组成部分是恢复原有的唇瓣功能。环形唇重建术(CLR)取得了积极的效果。假设(1) 采用无结 ASA 固定的环形唇重建术将恢复原始唇吸封生物力学;(2) 将 ASA 拉伸到高张力状态将增加峰值牵引力。研究设计对照实验室研究。方法解剖八只新鲜冷冻的人类尸体髋关节,除原生唇和髋臼横韧带外,去除所有软组织。在机电测试系统上,对髋关节施加 250 牛顿的压力以启动吸力密封,并以 10 毫米/秒的速度牵引,直至吸力密封破裂。髋关节在 4 种状态下进行了测试:完整的髋臼唇、完全切除的髋臼唇、具有中等锚定张力的无结 CLR 和具有高锚定张力的 CLR。使用重复测量方差分析比较了峰值牵张力(以牛顿为单位)(P < .05)。髋臼斜角 (θ)是在髋臼横韧带外的唇钟面位置使用三维数字化仪测针测量的。结果完整髋臼唇的峰值力为 138.5 ± 13.6 N(平均值 ± SE),髋臼唇切除为 18.4 ± 2.79 N,中度张力髋臼唇的峰值力为 95.4 ± 23.3 N,高度张力髋臼唇的峰值力为 126.2 ± 27.3 N。只有当完全切除唇缘与其他条件进行比较时,才能观察到显著差异:完整(P < .001)、中等张力CLR(P = .016)和高张力CLR(P = .002)。结论唇缺损后,CLR 可将分散稳定性平均恢复到完好值的 82.0%。这些研究结果提供了生物力学验证,支持使用无结 ASAs 进行 CLR,以尽量减少骨量损失并提供其他手术优势。准备好的边缘斜角可能是一个重要的变量,需要进行优化以改善吸引密封修复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reversal of Denervation Changes in Infraspinatus Muscle After Operative Management of Paralabral Cysts: An MRI-Based Study. Physiologic Preoperative Knee Hyperextension Is Not Associated With Postoperative Laxity, Subjective Knee Function, or Revision Surgery After ACL Reconstruction With Hamstring Tendon Autografts. All-Inside Endoscopic Classic Bröstrom-Gould Technique: Medium-term Results. Circumferential Labral Reconstruction With Knotless All-Suture Anchors Restores Hip Distractive Stability: A Cadaveric Biomechanical Analysis. Survivorship and Outcomes of Meniscal Ramp Lesions Repaired Through a Posteromedial Portal During Anterior Cruciate Ligament Reconstruction: Outcome Study With a Minimum 10-Year Follow-up.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1