Understanding perioperative risk determinants in carotid endarterectomy: the impact of compromised circle of Willis morphology on inter-hemispheric blood flow indices based on intraoperative internal carotid artery stump pulse pressure and backflow patterns

IF 5.3 2区 医学 Q1 GERIATRICS & GERONTOLOGY GeroScience Pub Date : 2024-10-26 DOI:10.1007/s11357-024-01390-y
Zsófia Czinege, Ágnes Dóra Sándor, Dániel Gyürki, Andrea Varga, Tamás Csípő, Andrea Székely, Zoltán Ungvári, Péter Banga, Péter Sótonyi, Tamás Horváth
{"title":"Understanding perioperative risk determinants in carotid endarterectomy: the impact of compromised circle of Willis morphology on inter-hemispheric blood flow indices based on intraoperative internal carotid artery stump pulse pressure and backflow patterns","authors":"Zsófia Czinege, Ágnes Dóra Sándor, Dániel Gyürki, Andrea Varga, Tamás Csípő, Andrea Székely, Zoltán Ungvári, Péter Banga, Péter Sótonyi, Tamás Horváth","doi":"10.1007/s11357-024-01390-y","DOIUrl":null,"url":null,"abstract":"<p>Carotid artery stenosis (CAS) often requires surgical intervention through carotid endarterectomy (CEA) to prevent stroke. Accurate cerebrovascular risk assessments are crucial in CEA, as poor collateral circulation can lead to insufficient interhemispheric blood flow compensation, resulting in ischemic complications. Therefore, understanding perioperative risk determinants is vital. This study aims to determine the impact of compromised circle of Willis (CoW) morphology on inter-hemispheric blood flow, focusing on indices based on intraoperative internal carotid artery stump pulse pressure and backflow patterns. In 80 CAS patients who underwent CEA, preoperative CT angiography for CoW was conducted. Patients were categorized into five subgroups based on their CoW anatomy and three additional groups based on intraoperative internal carotid artery (ICA) stump backflow patterns evaluated by the surgeon. Continuous blood pressure signals, including systolic, diastolic, mean, and pulse pressure values, were recorded during the procedure. The relationship between CoW anatomical variants and the systolic and diastolic segments of the averaged pressure waveforms, particularly diastolic pressure decay, was analyzed. The correlation between CoW anatomy and stump backflow intensity was also examined. Significant variability in ICA stump backflow and pressure values was evident across CoW variants. Patients with compromised CoW morphology exhibited weaker backflow patterns and lower ICA stump pulse pressure values, consistent with impaired interhemispheric blood flow. Notably, ICA stump diastolic pressure decay was consistent across most CoW variant groups, indicating developed collateral circulation in cases with CoW anomalies. Thus, impaired CoW integrity is associated with compromised interhemispheric blood flow indices based on intraoperative ICA stump pulse pressure and backflow patterns during CEA. Integrating intraoperative pulse waveform analysis with preoperative CT angiography provides a more detailed assessment of cerebrovascular risk, guiding the selective use of shunts. This combined approach may improve surgical outcomes and patient safety by identifying patients at increased risk of perioperative neurological events due to CoW anomalies.</p>","PeriodicalId":12730,"journal":{"name":"GeroScience","volume":"60 1","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2024-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"GeroScience","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11357-024-01390-y","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"GERIATRICS & GERONTOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Carotid artery stenosis (CAS) often requires surgical intervention through carotid endarterectomy (CEA) to prevent stroke. Accurate cerebrovascular risk assessments are crucial in CEA, as poor collateral circulation can lead to insufficient interhemispheric blood flow compensation, resulting in ischemic complications. Therefore, understanding perioperative risk determinants is vital. This study aims to determine the impact of compromised circle of Willis (CoW) morphology on inter-hemispheric blood flow, focusing on indices based on intraoperative internal carotid artery stump pulse pressure and backflow patterns. In 80 CAS patients who underwent CEA, preoperative CT angiography for CoW was conducted. Patients were categorized into five subgroups based on their CoW anatomy and three additional groups based on intraoperative internal carotid artery (ICA) stump backflow patterns evaluated by the surgeon. Continuous blood pressure signals, including systolic, diastolic, mean, and pulse pressure values, were recorded during the procedure. The relationship between CoW anatomical variants and the systolic and diastolic segments of the averaged pressure waveforms, particularly diastolic pressure decay, was analyzed. The correlation between CoW anatomy and stump backflow intensity was also examined. Significant variability in ICA stump backflow and pressure values was evident across CoW variants. Patients with compromised CoW morphology exhibited weaker backflow patterns and lower ICA stump pulse pressure values, consistent with impaired interhemispheric blood flow. Notably, ICA stump diastolic pressure decay was consistent across most CoW variant groups, indicating developed collateral circulation in cases with CoW anomalies. Thus, impaired CoW integrity is associated with compromised interhemispheric blood flow indices based on intraoperative ICA stump pulse pressure and backflow patterns during CEA. Integrating intraoperative pulse waveform analysis with preoperative CT angiography provides a more detailed assessment of cerebrovascular risk, guiding the selective use of shunts. This combined approach may improve surgical outcomes and patient safety by identifying patients at increased risk of perioperative neurological events due to CoW anomalies.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
了解颈动脉内膜切除术围手术期的风险决定因素:基于术中颈内动脉残端脉压和回流模式的威利斯圈形态受损对半球间血流指数的影响
颈动脉狭窄(CAS)通常需要通过颈动脉内膜剥脱术(CEA)进行手术干预,以预防中风。准确的脑血管风险评估对 CEA 至关重要,因为侧支循环不良会导致大脑半球间血流补偿不足,从而引发缺血性并发症。因此,了解围手术期的风险决定因素至关重要。本研究旨在确定威利斯圈(CoW)形态受损对半球间血流的影响,重点是基于术中颈内动脉残端脉压和回流模式的指数。在 80 例接受 CEA 的 CAS 患者中,术前对 CoW 进行了 CT 血管造影。根据CoW解剖结构将患者分为五个亚组,并根据外科医生评估的术中颈内动脉(ICA)残端回流模式将患者分为另外三组。手术过程中记录了连续血压信号,包括收缩压、舒张压、平均血压和脉压值。分析了CoW解剖变异与平均压力波形的收缩和舒张段之间的关系,尤其是舒张压衰减。此外,还研究了CoW解剖结构与残端回流强度之间的相关性。不同CoW变体的ICA残端回流和压力值存在明显差异。CoW形态受损的患者表现出较弱的回流模式和较低的ICA残端脉压值,这与半球间血流受损一致。值得注意的是,ICA残端舒张压衰减在大多数CoW变异组中都是一致的,这表明CoW异常的病例侧支循环发达。因此,CoW完整性受损与基于术中ICA残端脉压和CEA期间回流模式的半球间血流指数受损有关。将术中脉搏波形分析与术前 CT 血管造影相结合,可以更详细地评估脑血管风险,从而指导有选择性地使用分流术。这种联合方法可以识别因CoW异常而导致围术期神经事件风险增加的患者,从而改善手术效果和患者安全。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
GeroScience
GeroScience Medicine-Complementary and Alternative Medicine
CiteScore
10.50
自引率
5.40%
发文量
182
期刊介绍: GeroScience is a bi-monthly, international, peer-reviewed journal that publishes articles related to research in the biology of aging and research on biomedical applications that impact aging. The scope of articles to be considered include evolutionary biology, biophysics, genetics, genomics, proteomics, molecular biology, cell biology, biochemistry, endocrinology, immunology, physiology, pharmacology, neuroscience, and psychology.
期刊最新文献
Dialysis disequilibrium syndrome in neurosurgery: literature review and illustrative case example. The impact of exercise on blood-based biomarkers of Alzheimer's disease in cognitively unimpaired older adults. Dynamics of serum exosome microRNA profile altered by chemically induced estropause and rescued by estrogen therapy in female mice. Fitness age outperforms body mass index in differentiating aging patterns and health risk profiles of healthy adults aged 51-80 years. Detecting aortic valve stenosis based on the non-invasive blood pressure waveform-a proof of concept study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1