An Analytical View on the Use of Flucloxacillin for Outpatient Parenteral Antimicrobial Therapy.

IF 4.1 2区 生物学 Q2 MICROBIOLOGY Microorganisms Pub Date : 2024-10-09 DOI:10.3390/microorganisms12102039
Tam Nguyen, Isabel Spriet, Charlotte Quintens, Lotte Vander Elst, Pham Thi Thanh Ha, Ann Van Schepdael, Erwin Adams
{"title":"An Analytical View on the Use of Flucloxacillin for Outpatient Parenteral Antimicrobial Therapy.","authors":"Tam Nguyen, Isabel Spriet, Charlotte Quintens, Lotte Vander Elst, Pham Thi Thanh Ha, Ann Van Schepdael, Erwin Adams","doi":"10.3390/microorganisms12102039","DOIUrl":null,"url":null,"abstract":"<p><p>Although the addition of buffers provides improved stability to flucloxacillin (FLU) solutions, unbuffered solutions are often preferred in clinical practice. The first purpose of this study was to investigate whether a 50 mg/mL solution of FLU in normal saline is stable for 24 h at 33 °C so that it can be applied for outpatient parenteral antimicrobial therapy (OPAT) using portable elastomeric infusion pumps (PEIPs). When the PEIPs were stored in an oven at 33 °C and deflated over 24 h, the volume of the collected solution, pH, and FLU concentration were checked every 4 h. Obtaining better results than expected based on the literature data, other storage conditions, such as refrigeration, room temperature (RT), 37 °C, refrigeration followed by 24 h at 33 °C and 37 °C, and different batches/brands, were also tested. This study confirmed the pronounced effect of temperature on the stability of FLU and also showed the relationship between the stability of FLU and the initial pH of the solution. FLU was quite stable at refrigeration and RT conditions, with more than 99% and 95% remaining. After 24 h at 33 °C, more than 92% of FLU was still present in the solution, while this number decreased to less than 85% when the storage temperature reached 37 °C. The remaining percentage was found to be even lower when the solution was stored at 2-8 °C for 6 days, followed by 24 h storage at 33 °C or 37 °C, with losses of 17% and 30%, respectively. The stability of FLU became worse when the initial pH of the solution was lower than 5.9 since the concentration of FLU dropped to less than 90% after 24 h at 33 °C, and a precipitate started to form when the initial pH of the solution was around 5.3. Therefore, FLU in PEIPs could be employed for 24 h if the temperature was ideally not more than 33 °C, while the pH should be not less than 5.9 upon reconstituting the FLU solution.</p>","PeriodicalId":18667,"journal":{"name":"Microorganisms","volume":null,"pages":null},"PeriodicalIF":4.1000,"publicationDate":"2024-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11509857/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microorganisms","FirstCategoryId":"99","ListUrlMain":"https://doi.org/10.3390/microorganisms12102039","RegionNum":2,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Although the addition of buffers provides improved stability to flucloxacillin (FLU) solutions, unbuffered solutions are often preferred in clinical practice. The first purpose of this study was to investigate whether a 50 mg/mL solution of FLU in normal saline is stable for 24 h at 33 °C so that it can be applied for outpatient parenteral antimicrobial therapy (OPAT) using portable elastomeric infusion pumps (PEIPs). When the PEIPs were stored in an oven at 33 °C and deflated over 24 h, the volume of the collected solution, pH, and FLU concentration were checked every 4 h. Obtaining better results than expected based on the literature data, other storage conditions, such as refrigeration, room temperature (RT), 37 °C, refrigeration followed by 24 h at 33 °C and 37 °C, and different batches/brands, were also tested. This study confirmed the pronounced effect of temperature on the stability of FLU and also showed the relationship between the stability of FLU and the initial pH of the solution. FLU was quite stable at refrigeration and RT conditions, with more than 99% and 95% remaining. After 24 h at 33 °C, more than 92% of FLU was still present in the solution, while this number decreased to less than 85% when the storage temperature reached 37 °C. The remaining percentage was found to be even lower when the solution was stored at 2-8 °C for 6 days, followed by 24 h storage at 33 °C or 37 °C, with losses of 17% and 30%, respectively. The stability of FLU became worse when the initial pH of the solution was lower than 5.9 since the concentration of FLU dropped to less than 90% after 24 h at 33 °C, and a precipitate started to form when the initial pH of the solution was around 5.3. Therefore, FLU in PEIPs could be employed for 24 h if the temperature was ideally not more than 33 °C, while the pH should be not less than 5.9 upon reconstituting the FLU solution.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
门诊外用抗菌药物治疗中使用氟氯西林的分析观点。
尽管添加缓冲剂可提高氟氯西林(FLU)溶液的稳定性,但临床实践中通常还是倾向于使用未添加缓冲剂的溶液。本研究的第一个目的是调查 50 mg/mL 的氟氯西林在生理盐水中的溶液在 33 ° C 下 24 小时内是否稳定,以便将其用于使用便携式弹性输液泵(PEIP)的门诊肠外抗菌治疗(OPAT)。将 PEIP 储存在 33 °C 的烘箱中并放气 24 小时后,每隔 4 小时检查一次收集溶液的体积、pH 值和 FLU 浓度。根据文献数据,结果比预期的要好,因此还测试了其他储存条件,如冷藏、室温 (RT)、37 °C、冷藏后在 33 °C 和 37 °C 下储存 24 小时,以及不同的批次/品牌。这项研究证实了温度对 FLU 稳定性的显著影响,同时还显示了 FLU 稳定性与溶液初始 pH 值之间的关系。FLU 在冷藏和 RT 条件下相当稳定,剩余率分别超过 99% 和 95%。在 33 °C 下保存 24 小时后,溶液中仍有超过 92% 的 FLU,而当保存温度达到 37 °C 时,这一数字下降到了 85% 以下。当溶液在 2 至 8 °C 下储存 6 天,然后在 33 °C 或 37 °C 下储存 24 小时后,发现剩余的百分比更低,分别损失了 17% 和 30%。当溶液的初始 pH 值低于 5.9 时,FLU 的稳定性变差,因为在 33 °C 下存放 24 小时后,FLU 的浓度下降到 90% 以下,当溶液的初始 pH 值在 5.3 左右时,开始形成沉淀。因此,如果温度最好不超过 33 °C,PEIP 中的 FLU 可使用 24 小时,而重新配制 FLU 溶液时的 pH 值应不低于 5.9。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Microorganisms
Microorganisms Medicine-Microbiology (medical)
CiteScore
7.40
自引率
6.70%
发文量
2168
审稿时长
20.03 days
期刊介绍: Microorganisms (ISSN 2076-2607) is an international, peer-reviewed open access journal which provides an advanced forum for studies related to prokaryotic and eukaryotic microorganisms, viruses and prions. It publishes reviews, research papers and communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Electronic files and software regarding the full details of the calculation or experimental procedure, if unable to be published in a normal way, can be deposited as supplementary electronic material.
期刊最新文献
A New Real-Time PCR Test (Flora Select™) and Nugent Score for the Diagnosis of Bacterial Vaginosis During Pregnancy. A Novel Cold-Adapted Nitronate Monooxygenase from Psychrobacter sp. ANT206: Identification, Characterization and Degradation of 2-Nitropropane at Low Temperature. Antibiotic Susceptibility-Guided Concomitant Therapy Regimen with Vonoprazan, High-Dose Amoxicillin, Clarithromycin, and Metronidazole for Helicobacter pylori Eradication as Fourth-Line Regimen: An Interventional Study. Potentially Pathogenic Vibrio spp. in Algal Wrack Accumulations on Baltic Sea Sandy Beaches. Coinfection of Toxoplasma gondii and Other Microorganisms: A Systematic Review and Meta-Analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1