{"title":"Revolutionizing endometriosis treatment: automated surgical operation through artificial intelligence and robotic vision.","authors":"Sina Saadati, Maryam Amirmazlaghani","doi":"10.1007/s11701-024-02139-7","DOIUrl":null,"url":null,"abstract":"<p><p>Clinical limitations due to poverty significantly impact the lives and health of many individuals globally. Nevertheless, this challenge can be addressed with modern technologies, particularly through robotics and artificial intelligence. This study aims to address these challenges using advanced technologies in robotic surgery and artificial intelligence, proposing a method to fully automate endometriosis robotic surgery with a focus on interpretability, accuracy, and reliability. A methodology for fully automatic endometriosis surgery is introduced. Given the complexity of endometriosis lesions detection, they are categorized by their anatomical location to improve system interpretability. Then, three ensemble U-Net frameworks are designed to detect and localize common types of endometriosis lesions intraoperatively. A cross-training approach is employed, exploring U-Net models with diverse neural architectures-such as ResNet50, ResNet101, VGG19, InceptionV3, MobileNet, and EfficientNetB7-to develop U-Net ensemble models for precise endometriosis lesions segmentation. A novel image augmentation technique is also introduced, enhancing the segmentation models' accuracy and reliability. Furthermore, two U-Net models are developed to localize the ovaries and uterus, mitigating unexpected noise and bolstering the method's accuracy and reliability. The image segmentation models, assessed using the Intersection over Union (IoU) metric, achieved outstanding results: 97.57% for ovarian, 96.35% for uterine, and 92.58% for peritoneal endometriosis. This study proposes a fully automatic method for some common types of endometriosis surgery, including ovarian endometriomas and superficial endometriosis. This method is centered around three ensemble U-Net frameworks and a noise reduction technique using two additional U-Nets for localizing the ovaries and uterus. This approach has the potential to significantly improve the accuracy and reliability of robotic surgeries, potentially reducing healthcare costs and improving outcomes for patients worldwide.</p>","PeriodicalId":47616,"journal":{"name":"Journal of Robotic Surgery","volume":"18 1","pages":"383"},"PeriodicalIF":2.2000,"publicationDate":"2024-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Robotic Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11701-024-02139-7","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Clinical limitations due to poverty significantly impact the lives and health of many individuals globally. Nevertheless, this challenge can be addressed with modern technologies, particularly through robotics and artificial intelligence. This study aims to address these challenges using advanced technologies in robotic surgery and artificial intelligence, proposing a method to fully automate endometriosis robotic surgery with a focus on interpretability, accuracy, and reliability. A methodology for fully automatic endometriosis surgery is introduced. Given the complexity of endometriosis lesions detection, they are categorized by their anatomical location to improve system interpretability. Then, three ensemble U-Net frameworks are designed to detect and localize common types of endometriosis lesions intraoperatively. A cross-training approach is employed, exploring U-Net models with diverse neural architectures-such as ResNet50, ResNet101, VGG19, InceptionV3, MobileNet, and EfficientNetB7-to develop U-Net ensemble models for precise endometriosis lesions segmentation. A novel image augmentation technique is also introduced, enhancing the segmentation models' accuracy and reliability. Furthermore, two U-Net models are developed to localize the ovaries and uterus, mitigating unexpected noise and bolstering the method's accuracy and reliability. The image segmentation models, assessed using the Intersection over Union (IoU) metric, achieved outstanding results: 97.57% for ovarian, 96.35% for uterine, and 92.58% for peritoneal endometriosis. This study proposes a fully automatic method for some common types of endometriosis surgery, including ovarian endometriomas and superficial endometriosis. This method is centered around three ensemble U-Net frameworks and a noise reduction technique using two additional U-Nets for localizing the ovaries and uterus. This approach has the potential to significantly improve the accuracy and reliability of robotic surgeries, potentially reducing healthcare costs and improving outcomes for patients worldwide.
期刊介绍:
The aim of the Journal of Robotic Surgery is to become the leading worldwide journal for publication of articles related to robotic surgery, encompassing surgical simulation and integrated imaging techniques. The journal provides a centralized, focused resource for physicians wishing to publish their experience or those wishing to avail themselves of the most up-to-date findings.The journal reports on advance in a wide range of surgical specialties including adult and pediatric urology, general surgery, cardiac surgery, gynecology, ENT, orthopedics and neurosurgery.The use of robotics in surgery is broad-based and will undoubtedly expand over the next decade as new technical innovations and techniques increase the applicability of its use. The journal intends to capture this trend as it develops.