[Discussion on Magnetic Resonance Compatibility of Implantable Brain-Computer Interface Devices].

Kaixiang Jin, Xun Liu, Sheng Hu, Yonghua Li, Yuetong Wu, Jiaxing Li, Chenghuai Mo
{"title":"[Discussion on Magnetic Resonance Compatibility of Implantable Brain-Computer Interface Devices].","authors":"Kaixiang Jin, Xun Liu, Sheng Hu, Yonghua Li, Yuetong Wu, Jiaxing Li, Chenghuai Mo","doi":"10.12455/j.issn.1671-7104.240232","DOIUrl":null,"url":null,"abstract":"<p><p>Brain-computer interface (BCI) devices are crucial tools for neural stimulation and recording, offering broad prospects in the diagnosis and treatment of neurological disorders. Furthermore, magnetic resonance imaging (MRI) is an effective and non-invasive technique for capturing whole-brain signals, providing detailed information on brain structures and activation patterns. Integrating the neural stimulation/recording capabilities of BCI devices with the non-invasive detection function of MRI is considered highly significant for brain function analysis. However, this combination imposes specific requirements on the magnetic and electronic performance of neural interface devices. The interaction between BCI devices and MRI is initially explored. Subsequently, potential safety risks arising from their combination are summarized and organized. Starting from the source of these hazards, such as the metallic electrodes and wires of BCI devices, the issues are analyzed, and current research countermeasures are summarized. In conclusion, the regulatory oversight of BCI's magnetic resonance safety is briefly discussed, and suggestions for enhancing the magnetic resonance compatibility of related BCI devices are proposed.</p>","PeriodicalId":52535,"journal":{"name":"中国医疗器械杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国医疗器械杂志","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.12455/j.issn.1671-7104.240232","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Brain-computer interface (BCI) devices are crucial tools for neural stimulation and recording, offering broad prospects in the diagnosis and treatment of neurological disorders. Furthermore, magnetic resonance imaging (MRI) is an effective and non-invasive technique for capturing whole-brain signals, providing detailed information on brain structures and activation patterns. Integrating the neural stimulation/recording capabilities of BCI devices with the non-invasive detection function of MRI is considered highly significant for brain function analysis. However, this combination imposes specific requirements on the magnetic and electronic performance of neural interface devices. The interaction between BCI devices and MRI is initially explored. Subsequently, potential safety risks arising from their combination are summarized and organized. Starting from the source of these hazards, such as the metallic electrodes and wires of BCI devices, the issues are analyzed, and current research countermeasures are summarized. In conclusion, the regulatory oversight of BCI's magnetic resonance safety is briefly discussed, and suggestions for enhancing the magnetic resonance compatibility of related BCI devices are proposed.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[讨论植入式脑机接口设备的磁共振兼容性]。
脑机接口(BCI)设备是神经刺激和记录的重要工具,为神经系统疾病的诊断和治疗提供了广阔的前景。此外,磁共振成像(MRI)是一种捕捉全脑信号的有效非侵入性技术,可提供有关大脑结构和激活模式的详细信息。将 BCI 设备的神经刺激/记录功能与磁共振成像的无创检测功能相结合,被认为对脑功能分析意义重大。然而,这种结合对神经接口设备的磁性和电子性能提出了具体要求。本文首先探讨了 BCI 设备与核磁共振成像之间的相互作用。随后,总结并整理了两者结合所产生的潜在安全风险。从这些危险的源头(如 BCI 设备的金属电极和导线)入手,对问题进行了分析,并总结了当前的研究对策。最后,简要讨论了对 BCI 磁共振安全性的监管,并提出了提高相关 BCI 设备磁共振兼容性的建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中国医疗器械杂志
中国医疗器械杂志 Medicine-Medicine (all)
CiteScore
0.40
自引率
0.00%
发文量
8086
期刊介绍:
期刊最新文献
[12-Lead Holter Integrated with Sleep Monitoring Module]. [Bowel Sounds Detection Method Based on ResNet-BiLSTM and Attention Mechanism]. [Clinical Application of Equivalent Uniform Dose in Intensity-Modulated Rotational Radiotherapy Based on Eclipse TPS]. [Clinical Validation of a Prototype Smart Non-Invasive Pregnancy Glucose Monitor]. [Clinical Validation Study of Deep Learning-Generated Magnetic Resonance Images].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1