Bernadette Quah , Ali Sulaiman Al Yousef , Clement Wei Ming Lai , Raymond Chung Wen Wong , Ren Jie Jacob Chew
{"title":"Impact of Implant Design on Outcomes of Simultaneous Guided Bone Regeneration for Dehiscence Defects: A Systematic Review and Meta-Analysis","authors":"Bernadette Quah , Ali Sulaiman Al Yousef , Clement Wei Ming Lai , Raymond Chung Wen Wong , Ren Jie Jacob Chew","doi":"10.1016/j.jebdp.2024.102033","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><div>This systematic review and meta-analysis aimed to determine the implications of implant design on the outcomes of simultaneous guided bone regeneration (GBR) to correct dehiscence defects.</div></div><div><h3>Methods</h3><div>A structured search strategy was applied to MEDLINE (PubMed), Cochrane Library, and Embase, to identify prospective clinical trials involving implants with simultaneous GBR to correct dehiscence defects. Data regarding implant characteristics, GBR materials, as well as dehiscence defect dimensions at implant placement and surgical re-entry was collected. Meta-analyses were performed to estimate the pooled mean for (1) baseline dehiscence defect dimensions, (2) changes in defect dimensions at re-entry, and (3) prevalence of complete defect resolution.</div></div><div><h3>Results</h3><div>4298 unique records were identified, of which 21 studies with 680 implants were included. Despite having comparable baseline defect dimensions, greater height gains were achieved by implants with machined collars (MC) than noncollared (NC) implants (4.40 mm, 95% CI [3.70, 5.11] and 3.23 mm, 95% CI [2.72, 3.75] respectively), with significant subgroup differences (<em>P</em> < .01). Specifically, superior outcomes were observed for MC with space-maintaining geometries. However, there were no significant differences in the changes in defect width, prevalence of complete defect resolution, or the prevalence of postsurgical complication rates (<em>P</em> = .15, .54, and .18 respectively).</div></div><div><h3>Conclusions</h3><div>The regenerative outcomes of GBR were influenced by the implant design. Space-maintaining machined collars provide a tenting effect that improves vertical bone gain. While additional research is required to ascertain these findings and integrate choices regarding implant design into clinical decision-making, clinicians may consider replicating this effect to enhance treatment outcomes.</div></div>","PeriodicalId":48736,"journal":{"name":"Journal of Evidence-Based Dental Practice","volume":"24 4","pages":"Article 102033"},"PeriodicalIF":4.1000,"publicationDate":"2024-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Evidence-Based Dental Practice","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1532338224000836","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0
Abstract
Objective
This systematic review and meta-analysis aimed to determine the implications of implant design on the outcomes of simultaneous guided bone regeneration (GBR) to correct dehiscence defects.
Methods
A structured search strategy was applied to MEDLINE (PubMed), Cochrane Library, and Embase, to identify prospective clinical trials involving implants with simultaneous GBR to correct dehiscence defects. Data regarding implant characteristics, GBR materials, as well as dehiscence defect dimensions at implant placement and surgical re-entry was collected. Meta-analyses were performed to estimate the pooled mean for (1) baseline dehiscence defect dimensions, (2) changes in defect dimensions at re-entry, and (3) prevalence of complete defect resolution.
Results
4298 unique records were identified, of which 21 studies with 680 implants were included. Despite having comparable baseline defect dimensions, greater height gains were achieved by implants with machined collars (MC) than noncollared (NC) implants (4.40 mm, 95% CI [3.70, 5.11] and 3.23 mm, 95% CI [2.72, 3.75] respectively), with significant subgroup differences (P < .01). Specifically, superior outcomes were observed for MC with space-maintaining geometries. However, there were no significant differences in the changes in defect width, prevalence of complete defect resolution, or the prevalence of postsurgical complication rates (P = .15, .54, and .18 respectively).
Conclusions
The regenerative outcomes of GBR were influenced by the implant design. Space-maintaining machined collars provide a tenting effect that improves vertical bone gain. While additional research is required to ascertain these findings and integrate choices regarding implant design into clinical decision-making, clinicians may consider replicating this effect to enhance treatment outcomes.
期刊介绍:
The Journal of Evidence-Based Dental Practice presents timely original articles, as well as reviews of articles on the results and outcomes of clinical procedures and treatment. The Journal advocates the use or rejection of a procedure based on solid, clinical evidence found in literature. The Journal''s dynamic operating principles are explicitness in process and objectives, publication of the highest-quality reviews and original articles, and an emphasis on objectivity.