Arthroscopic Fixation With Absorbable Suture Anchors for Pipkin Type I Femoral Head Fractures—Letter V Technique

IF 1.2 Q3 ORTHOPEDICS Arthroscopy Techniques Pub Date : 2024-10-01 DOI:10.1016/j.eats.2024.103090
Xiang-Yu Yin M.D., Yi Liu M.D., Wen-Guang Liu M.D., Qing-Feng Yin M.D.
{"title":"Arthroscopic Fixation With Absorbable Suture Anchors for Pipkin Type I Femoral Head Fractures—Letter V Technique","authors":"Xiang-Yu Yin M.D.,&nbsp;Yi Liu M.D.,&nbsp;Wen-Guang Liu M.D.,&nbsp;Qing-Feng Yin M.D.","doi":"10.1016/j.eats.2024.103090","DOIUrl":null,"url":null,"abstract":"<div><div>Femoral head fractures are relatively uncommon high-energy injuries and usually associated with traumatic hip dislocation. Pipkin classified these fractures into 4 types according to the location of the head fragment related to the fovea and associated lesions on the femoral neck or acetabulum. Traditional open reduction and internal fixation for femoral head fracture has been proven to be effective, but it could be associated with significant complications. Arthroscopic fixation with screws is a less-invasive alternative to open reduction and internal fixation that offers several advantages. However, technical challenges could be encountered during the procedure and catastrophic consequences could occur in cases of fixation failure. Therefore, we propose an effective arthroscopic technique for Pipkin type I (small fracture caudal to the fovea capitis) femoral head fractures that uses an absorbable suture anchors. The anchors provide initial stability to the fracture fragments, and then the sutures are tied in a double-pulley fashion to further secure the fracture. Finally, a triangular suture bridge (“letter V”) is created, which supplies a convenient and stable fixation for proper femoral head fracture.</div></div>","PeriodicalId":47827,"journal":{"name":"Arthroscopy Techniques","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Arthroscopy Techniques","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S221262872400207X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Femoral head fractures are relatively uncommon high-energy injuries and usually associated with traumatic hip dislocation. Pipkin classified these fractures into 4 types according to the location of the head fragment related to the fovea and associated lesions on the femoral neck or acetabulum. Traditional open reduction and internal fixation for femoral head fracture has been proven to be effective, but it could be associated with significant complications. Arthroscopic fixation with screws is a less-invasive alternative to open reduction and internal fixation that offers several advantages. However, technical challenges could be encountered during the procedure and catastrophic consequences could occur in cases of fixation failure. Therefore, we propose an effective arthroscopic technique for Pipkin type I (small fracture caudal to the fovea capitis) femoral head fractures that uses an absorbable suture anchors. The anchors provide initial stability to the fracture fragments, and then the sutures are tied in a double-pulley fashion to further secure the fracture. Finally, a triangular suture bridge (“letter V”) is created, which supplies a convenient and stable fixation for proper femoral head fracture.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
关节镜下用可吸收缝合锚固定 Pipkin I 型股骨头骨折--Letter V 技术
股骨头骨折是比较少见的高能量损伤,通常与外伤性髋关节脱位有关。Pipkin 根据股骨头碎片与股骨头窝的相关位置以及股骨颈或髋臼的相关病变,将这类骨折分为 4 种类型。传统的股骨头骨折切开复位内固定术已被证实有效,但可能会引起严重的并发症。关节镜下螺钉固定是一种创伤较小的方法,可替代切开复位和内固定,具有多种优势。然而,手术过程中可能会遇到技术难题,如果固定失败,可能会造成灾难性后果。因此,我们提出了一种有效的关节镜技术,使用可吸收缝合锚来治疗 Pipkin I 型(股骨头窝尾侧小骨折)股骨头骨折。缝合锚可初步稳定骨折片,然后以双滑轮方式进行缝合,进一步固定骨折。最后,形成一个三角形缝合桥("字母 V"),为股骨头骨折提供方便、稳定的固定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Arthroscopy Techniques
Arthroscopy Techniques ORTHOPEDICS-
CiteScore
2.10
自引率
33.30%
发文量
291
审稿时长
29 weeks
期刊最新文献
Arthroscopic Subpectoral Tenodesis of the Long Head of the Biceps Brachii Endoscopic Application of a Collagen Scaffold for Treatment of Achilles Tendinopathy Arthroscopic Anatomic Lateral Ankle Reconstruction Using Allograft: A Simplified Approach Double-Anchor Stapled Repair of the Medial Meniscus Posterior Root Microfragmented Adipose Tissue Associated With Collagen Membrane in the Treatment of Focal Knee Cartilage Defect
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1