Left atrial posterior wall isolation in addition to pulmonary vein isolation using a pentaspline catheter in pulsed-field ablation for atrial fibrillation: A systematic review and meta-analysis
Raymond Pranata MD, William Kamarullah MD, Giky Karwiky MD, Chaerul Achmad MD, PhD, Mohammad Iqbal MD, PhD
{"title":"Left atrial posterior wall isolation in addition to pulmonary vein isolation using a pentaspline catheter in pulsed-field ablation for atrial fibrillation: A systematic review and meta-analysis","authors":"Raymond Pranata MD, William Kamarullah MD, Giky Karwiky MD, Chaerul Achmad MD, PhD, Mohammad Iqbal MD, PhD","doi":"10.1016/j.hroo.2024.08.006","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Persistent atrial fibrillation (AF) may require extensive ablation strategies. Left atrial posterior wall isolation (LAPWI) might address potential substrates for recurrence during pulsed-field ablation (PFA).</div></div><div><h3>Objective</h3><div>This meta-analysis aimed to investigate the feasibility and effectiveness of LAPWI in addition to pulmonary vein isolation (PVI) using a pentaspline catheter in PFA for AF.</div></div><div><h3>Methods</h3><div>Comprehensive search was conducted using PubMed, SCOPUS, ScienceDirect, and EuropePMC for studies reporting LAPWI+PVI using a pentaspline catheter in PFA ablation for AF. The primary outcome was atrial tachyarrhythmia (ATa) recurrence, defined as AF/atrial flutter/atrial tachycardia after blanking period.</div></div><div><h3>Results</h3><div>There were 882 patients from 7 studies. The success rate of LAPWI was 100% using mean/median of 16 to 20 added PFA applications with no reported acute left atrial posterior wall reconnection and esophageal complications. In mean follow-up of 240 ± 91 days, ATa recurrence was 21% (95% CI 13%–29%; I<sup>2</sup> = 84.8%) in the LAPWI+PVI group. Meta-regression analysis showed that age, left ventricular ejection fraction, and repeat procedure did not significantly influence ATa recurrence (<em>P</em> > .05). Each 1-mm increase in left atrial diameter, increases the chance of ATa recurrence by 6% (R<sup>2</sup> = 100%, <em>P</em> < .001, I<sup>2</sup> = 0%). Meta-analysis showed no difference in terms of ATa recurrence among LAPWI+PVI patients compared with those without LAPWI (odds ratio 0.78, 95% confidence interval 0.50–1.21, <em>P</em> = .27; I<sup>2</sup> = 0%, <em>P</em> = .86). Procedure time and fluoroscopy time did not significantly differ (<em>P</em> > .05).</div></div><div><h3>Conclusion</h3><div>LAPWI using a pentaspline catheter during PFA was feasible and did not prolong the procedure/fluoroscopy but did not reduce ATa recurrence. LAPWI may be considered during PFA, although the benefit is uncertain.</div></div>","PeriodicalId":29772,"journal":{"name":"Heart Rhythm O2","volume":"5 10","pages":"Pages 720-727"},"PeriodicalIF":2.5000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart Rhythm O2","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666501824002654","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Persistent atrial fibrillation (AF) may require extensive ablation strategies. Left atrial posterior wall isolation (LAPWI) might address potential substrates for recurrence during pulsed-field ablation (PFA).
Objective
This meta-analysis aimed to investigate the feasibility and effectiveness of LAPWI in addition to pulmonary vein isolation (PVI) using a pentaspline catheter in PFA for AF.
Methods
Comprehensive search was conducted using PubMed, SCOPUS, ScienceDirect, and EuropePMC for studies reporting LAPWI+PVI using a pentaspline catheter in PFA ablation for AF. The primary outcome was atrial tachyarrhythmia (ATa) recurrence, defined as AF/atrial flutter/atrial tachycardia after blanking period.
Results
There were 882 patients from 7 studies. The success rate of LAPWI was 100% using mean/median of 16 to 20 added PFA applications with no reported acute left atrial posterior wall reconnection and esophageal complications. In mean follow-up of 240 ± 91 days, ATa recurrence was 21% (95% CI 13%–29%; I2 = 84.8%) in the LAPWI+PVI group. Meta-regression analysis showed that age, left ventricular ejection fraction, and repeat procedure did not significantly influence ATa recurrence (P > .05). Each 1-mm increase in left atrial diameter, increases the chance of ATa recurrence by 6% (R2 = 100%, P < .001, I2 = 0%). Meta-analysis showed no difference in terms of ATa recurrence among LAPWI+PVI patients compared with those without LAPWI (odds ratio 0.78, 95% confidence interval 0.50–1.21, P = .27; I2 = 0%, P = .86). Procedure time and fluoroscopy time did not significantly differ (P > .05).
Conclusion
LAPWI using a pentaspline catheter during PFA was feasible and did not prolong the procedure/fluoroscopy but did not reduce ATa recurrence. LAPWI may be considered during PFA, although the benefit is uncertain.