Z Ashkir, A Abd Samat, L Finnigan, M A Ahktar, N Beyhoff, R Sarwar, E Wicks, O Rider, L Valkovic, M Mahmod, H Watkins, S Neubauer, B Raman
{"title":"Impaired myocardial energetics in both sarcomere positive and negative HCM are linked to arrhythmic risk","authors":"Z Ashkir, A Abd Samat, L Finnigan, M A Ahktar, N Beyhoff, R Sarwar, E Wicks, O Rider, L Valkovic, M Mahmod, H Watkins, S Neubauer, B Raman","doi":"10.1093/eurheartj/ehae666.2054","DOIUrl":null,"url":null,"abstract":"Background Impaired myocardial energetics play a pivotal role in the complex pathophysiology of hypertrophic cardiomyopathy (HCM), and are thought to be mediated by energy-costly sarcomeric mutations and mitochondrial dysfunction (1). Two thirds of HCM patients, however, do not possess pathogenic sarcomeric mutations (2) and instead develop the condition due to a combination of increased polygenic susceptibility and comorbidities. Whether energetic impairment, a target of novel HCM treatments (e.g., myosin modulators such as Mavacamten), similarly affects sarcomere mutation positive (Sarc+) and negative (Sarc-) HCM remains unclear, as does the association between impaired energetics and markers of arrhythmic risk such as hypertrophy severity, cardiac function and non-sustained ventricular tachycardia (NSVT). This study aimed to investigate differences in resting myocardial energetics between Sarc+ and Sarc- HCM by measuring the phosphocreatine-to-adenosine triphosphate (PCr/ATP) ratio using phosphorus magnetic resonance spectroscopy (31P-MRS) and explore the association between impaired energetics and markers of arrhythmic risk in HCM. Methods We recruited one hundred (100) participants (80 non-obstructive HCM patients and 20 age- and sex-matched controls). Myocardial energetics were assessed using 31P-MRS to measure the PCr/ATP ratio. Cardiac magnetic resonance (CMR) imaging including cine, T1 (ShMOLLI), quantitative pixel-wise perfusion mapping (3) and late gadolinium enhancement (LGE) imaging was also performed. In addition, HCM patients underwent 7-day ECG monitoring to document NSVT episodes (3 beats ≥120 bpm). Results HCM patients had impaired myocardial energetics (PCr/ATP ratio) relative to controls (HCM 1.64±0.36 vs controls 1.97±0.32 p<0.001). PCr/ATP ratios did not differ between Sarc+ and Sarc- HCM even after adjustment for confounders including age, hypertrophy and fibrosis burden (Sarc+ 1.64 [1.50-1.78] vs Sarc- 1.64 [1.52-1.77], p=0.993). PCr/ATP ratio showed no correlation with maximum wall thickness (p=0.257), left ventricular ejection fraction (p=0.727) or myocardial perfusion reserve (p=0.851), but did inversely correlate with global longitudinal strain (r=-0.3, p=0.025). Reduced PCr/ATP was associated with presence of fibrosis (LGE+ 1.58±0.35 vs LGE- 1.79±0.37 p=0.025) and with NSVT, independent of age or fibrosis burden (NSVT+ 1.54 [1.40-1.67] vs NSVT- 1.73 [1.62-1.86], p=0.046). Conclusion Myocardial energetics are similarly impaired in Sarc+ and Sarc- HCM, and are independently associated with impaired contractility, greater fibrosis severity and heightened arrhythmic risk. Our findings provide novel mechanistic insights into the potentially favourable response of HCM patients to energy-sparing myosin modulator therapies irrespective of genotype and highlight the potential for cardiac energetics to serve as a marker of arrhythmic risk.","PeriodicalId":37,"journal":{"name":"Environmental Science & Technology Letters Environ.","volume":"63 1","pages":""},"PeriodicalIF":8.9000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental Science & Technology Letters Environ.","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/eurheartj/ehae666.2054","RegionNum":2,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background Impaired myocardial energetics play a pivotal role in the complex pathophysiology of hypertrophic cardiomyopathy (HCM), and are thought to be mediated by energy-costly sarcomeric mutations and mitochondrial dysfunction (1). Two thirds of HCM patients, however, do not possess pathogenic sarcomeric mutations (2) and instead develop the condition due to a combination of increased polygenic susceptibility and comorbidities. Whether energetic impairment, a target of novel HCM treatments (e.g., myosin modulators such as Mavacamten), similarly affects sarcomere mutation positive (Sarc+) and negative (Sarc-) HCM remains unclear, as does the association between impaired energetics and markers of arrhythmic risk such as hypertrophy severity, cardiac function and non-sustained ventricular tachycardia (NSVT). This study aimed to investigate differences in resting myocardial energetics between Sarc+ and Sarc- HCM by measuring the phosphocreatine-to-adenosine triphosphate (PCr/ATP) ratio using phosphorus magnetic resonance spectroscopy (31P-MRS) and explore the association between impaired energetics and markers of arrhythmic risk in HCM. Methods We recruited one hundred (100) participants (80 non-obstructive HCM patients and 20 age- and sex-matched controls). Myocardial energetics were assessed using 31P-MRS to measure the PCr/ATP ratio. Cardiac magnetic resonance (CMR) imaging including cine, T1 (ShMOLLI), quantitative pixel-wise perfusion mapping (3) and late gadolinium enhancement (LGE) imaging was also performed. In addition, HCM patients underwent 7-day ECG monitoring to document NSVT episodes (3 beats ≥120 bpm). Results HCM patients had impaired myocardial energetics (PCr/ATP ratio) relative to controls (HCM 1.64±0.36 vs controls 1.97±0.32 p<0.001). PCr/ATP ratios did not differ between Sarc+ and Sarc- HCM even after adjustment for confounders including age, hypertrophy and fibrosis burden (Sarc+ 1.64 [1.50-1.78] vs Sarc- 1.64 [1.52-1.77], p=0.993). PCr/ATP ratio showed no correlation with maximum wall thickness (p=0.257), left ventricular ejection fraction (p=0.727) or myocardial perfusion reserve (p=0.851), but did inversely correlate with global longitudinal strain (r=-0.3, p=0.025). Reduced PCr/ATP was associated with presence of fibrosis (LGE+ 1.58±0.35 vs LGE- 1.79±0.37 p=0.025) and with NSVT, independent of age or fibrosis burden (NSVT+ 1.54 [1.40-1.67] vs NSVT- 1.73 [1.62-1.86], p=0.046). Conclusion Myocardial energetics are similarly impaired in Sarc+ and Sarc- HCM, and are independently associated with impaired contractility, greater fibrosis severity and heightened arrhythmic risk. Our findings provide novel mechanistic insights into the potentially favourable response of HCM patients to energy-sparing myosin modulator therapies irrespective of genotype and highlight the potential for cardiac energetics to serve as a marker of arrhythmic risk.
期刊介绍:
Environmental Science & Technology Letters serves as an international forum for brief communications on experimental or theoretical results of exceptional timeliness in all aspects of environmental science, both pure and applied. Published as soon as accepted, these communications are summarized in monthly issues. Additionally, the journal features short reviews on emerging topics in environmental science and technology.