{"title":"Evaluating the detection of barbiturates in dried blood spots: A comparative analysis using gas chromatography-mass spectrometry, gas chromatography-tandem mass spectrometry, and liquid chromatography-tandem mass spectrometry with different extraction methods","authors":"Yujie Zhi , Jiayue Lu , Qiongying Zheng , Xinyu Cao , Min Lv , Qing Xu , Ping Xiang , Wei Liu , Bin Di , Xianyu Fan , Hang Chen","doi":"10.1016/j.chroma.2024.465434","DOIUrl":null,"url":null,"abstract":"<div><div>Rapid and accurate characterization and quantitation of blood barbiturates and their combination drugs are very important for the clinical treatment of acute barbiturate poisoning. A comparison of dried blood spot (DBS) and traditional liquid-liquid extraction (LLE) in the pre-treatment stage, as well as a comparison of gas chromatography-mass spectrometry (GC–MS), gas chromatography-tandem mass spectrometry (GC–MS/MS), and liquid chromatography-tandem mass spectrometry (LC-MS/MS) as instrumental analysis methods, revealed differences in the analysis results of barbiturates and their combination drugs under different conditions. Based on these findings, we introduce a DBS-GC–MS/MS method. The developed and validated method showed good selectivity, sensitivity (LOD: 0.1 μg mL<sup>−1</sup>, LOQ: 0.2 μg mL<sup>−1</sup>), linearity (R<sup>2</sup>>0.9992), trueness (<15 %, except for carbamazepine, at 29.4 %), and precision (<15 %). Recovery was also good for most target compounds, but significant matrix effects were evident. Compared with the LLE method, the DBS method has the benefits of easy sample collection, storage, and transport, as well as simple pre-treatment and reduced reagent and energy consumption. Compared to LC-MS/MS, GC–MS/MS requires no switching between positive and negative ion modes and uses the MRM detection mode, meaning that more information about the sample compounds can be obtained in less analysis time. Using actual sample analysis, we have demonstrated the advantages of the DBS-GC–MS/MS method for the qualitative and quantitative analysis of barbiturates and poisoning events due to combinations of these drugs. Comparison of the three instruments and the two treatment methods revealed their analysis characteristics. From the perspective of practical application, the broad practical value and advantages of DBS should be embraced in more applications, and future analytical laboratory development should continue to recognize GC–MS/MS as a useful supplement to LC-MS/MS.</div></div>","PeriodicalId":347,"journal":{"name":"Journal of Chromatography A","volume":"1737 ","pages":"Article 465434"},"PeriodicalIF":3.8000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography A","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0021967324008082","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
Rapid and accurate characterization and quantitation of blood barbiturates and their combination drugs are very important for the clinical treatment of acute barbiturate poisoning. A comparison of dried blood spot (DBS) and traditional liquid-liquid extraction (LLE) in the pre-treatment stage, as well as a comparison of gas chromatography-mass spectrometry (GC–MS), gas chromatography-tandem mass spectrometry (GC–MS/MS), and liquid chromatography-tandem mass spectrometry (LC-MS/MS) as instrumental analysis methods, revealed differences in the analysis results of barbiturates and their combination drugs under different conditions. Based on these findings, we introduce a DBS-GC–MS/MS method. The developed and validated method showed good selectivity, sensitivity (LOD: 0.1 μg mL−1, LOQ: 0.2 μg mL−1), linearity (R2>0.9992), trueness (<15 %, except for carbamazepine, at 29.4 %), and precision (<15 %). Recovery was also good for most target compounds, but significant matrix effects were evident. Compared with the LLE method, the DBS method has the benefits of easy sample collection, storage, and transport, as well as simple pre-treatment and reduced reagent and energy consumption. Compared to LC-MS/MS, GC–MS/MS requires no switching between positive and negative ion modes and uses the MRM detection mode, meaning that more information about the sample compounds can be obtained in less analysis time. Using actual sample analysis, we have demonstrated the advantages of the DBS-GC–MS/MS method for the qualitative and quantitative analysis of barbiturates and poisoning events due to combinations of these drugs. Comparison of the three instruments and the two treatment methods revealed their analysis characteristics. From the perspective of practical application, the broad practical value and advantages of DBS should be embraced in more applications, and future analytical laboratory development should continue to recognize GC–MS/MS as a useful supplement to LC-MS/MS.
期刊介绍:
The Journal of Chromatography A provides a forum for the publication of original research and critical reviews on all aspects of fundamental and applied separation science. The scope of the journal includes chromatography and related techniques, electromigration techniques (e.g. electrophoresis, electrochromatography), hyphenated and other multi-dimensional techniques, sample preparation, and detection methods such as mass spectrometry. Contributions consist mainly of research papers dealing with the theory of separation methods, instrumental developments and analytical and preparative applications of general interest.