Determination of limit of detection (LOD) for loop-mediated isothermal amplification (LAMP) of human cytomegalovirus (hCMV) DNA

IF 2.1 4区 医学 Q3 INFECTIOUS DISEASES Diagnostic microbiology and infectious disease Pub Date : 2024-10-18 DOI:10.1016/j.diagmicrobio.2024.116567
Erkan Mozioğlu , Martin Hussels , Susanne Engel
{"title":"Determination of limit of detection (LOD) for loop-mediated isothermal amplification (LAMP) of human cytomegalovirus (hCMV) DNA","authors":"Erkan Mozioğlu ,&nbsp;Martin Hussels ,&nbsp;Susanne Engel","doi":"10.1016/j.diagmicrobio.2024.116567","DOIUrl":null,"url":null,"abstract":"<div><div>The importance of cytomegalovirus in clinical practice remains and samples are monitored for CMV DNA titers to predict the development of disease. LAMP assays have gained increasing interest in the diagnosis of many pathogens since they do not require thermocycling, reduce the complexity of the required instrumentation as well as providing sensitivity and rapidity. So far, very few studies on CMV detection by LAMP have been reported in the literature and therefore the performance of LAMP CMV assays needs to be further characterized. In a set-up for biometrological evaluation of the suitability of the LAMP assay for CMV diagnosis, a LAMP assay was performed on a total of 192 samples with 24 replicates of 8 different hCMV DNA concentrations. The LOD was calculated as 39.09 copy/reaction (25.33 copy/reaction to 65.84 copy/reaction) with 95 % confidence, representing a range that is suitable for qualitative detection. Furthermore, the lower limit of quantification was estimated at approximately 100 copy/reaction. The LOD and LLOQ values obtained in this first study to assess the biometrological relevance of LAMP CMV tests are consistent when compared to studies published before. However further study under different conditions is needed for the use of LAMP tests in clinical applications.</div></div>","PeriodicalId":11329,"journal":{"name":"Diagnostic microbiology and infectious disease","volume":"111 1","pages":"Article 116567"},"PeriodicalIF":2.1000,"publicationDate":"2024-10-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic microbiology and infectious disease","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0732889324003924","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INFECTIOUS DISEASES","Score":null,"Total":0}
引用次数: 0

Abstract

The importance of cytomegalovirus in clinical practice remains and samples are monitored for CMV DNA titers to predict the development of disease. LAMP assays have gained increasing interest in the diagnosis of many pathogens since they do not require thermocycling, reduce the complexity of the required instrumentation as well as providing sensitivity and rapidity. So far, very few studies on CMV detection by LAMP have been reported in the literature and therefore the performance of LAMP CMV assays needs to be further characterized. In a set-up for biometrological evaluation of the suitability of the LAMP assay for CMV diagnosis, a LAMP assay was performed on a total of 192 samples with 24 replicates of 8 different hCMV DNA concentrations. The LOD was calculated as 39.09 copy/reaction (25.33 copy/reaction to 65.84 copy/reaction) with 95 % confidence, representing a range that is suitable for qualitative detection. Furthermore, the lower limit of quantification was estimated at approximately 100 copy/reaction. The LOD and LLOQ values obtained in this first study to assess the biometrological relevance of LAMP CMV tests are consistent when compared to studies published before. However further study under different conditions is needed for the use of LAMP tests in clinical applications.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
确定人类巨细胞病毒 (hCMV) DNA 的环介导等温扩增 (LAMP) 检测限 (LOD)。
巨细胞病毒在临床实践中的重要性依然存在,人们通过监测样本中的巨细胞病毒 DNA 滴度来预测疾病的发展。LAMP 检测法无需热循环,降低了所需仪器的复杂性,灵敏度高且快速,因此在许多病原体的诊断中越来越受到关注。迄今为止,文献中关于通过 LAMP 检测 CMV 的研究报道很少,因此需要进一步确定 LAMP CMV 检测方法的性能。为了对 LAMP 检测法是否适用于 CMV 诊断进行生物计量学评估,我们对 8 种不同 hCMV DNA 浓度的 192 份样本进行了 24 次重复的 LAMP 检测。计算得出的 LOD 为 39.09 拷贝/反应(25.33 拷贝/反应至 65.84 拷贝/反应),置信度为 95%,这代表了适合定性检测的范围。此外,定量下限估计约为 100 个拷贝/反应。这项首次评估 LAMP CMV 检测生物计量学相关性的研究得出的 LOD 和 LLOQ 值与之前发表的研究结果一致。不过,在临床应用中使用 LAMP 检测还需要在不同条件下进行进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.30
自引率
3.40%
发文量
149
审稿时长
56 days
期刊介绍: Diagnostic Microbiology and Infectious Disease keeps you informed of the latest developments in clinical microbiology and the diagnosis and treatment of infectious diseases. Packed with rigorously peer-reviewed articles and studies in bacteriology, immunology, immunoserology, infectious diseases, mycology, parasitology, and virology, the journal examines new procedures, unusual cases, controversial issues, and important new literature. Diagnostic Microbiology and Infectious Disease distinguished independent editorial board, consisting of experts from many medical specialties, ensures you extensive and authoritative coverage.
期刊最新文献
Cover 2 - Aims/Scopes, Ed Board Successful treatment of infections caused by mycobacterium abscessus complex following aesthetic procedures: A case series in China Diagnostic value of metagenomic next-generation sequencing for bronchoalveolar lavage diagnostics in patients with lower respiratory tract infections Pseudallescheria boydii infection of the bloodstream system: First reported case from China Anti-biofilm activity of carvacrol-thymoquinone nanocarriers on vulvovaginal candidiasis isolates
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1