The effect of various denture cleansers on the physical and mechanical properties of CAD/CAM and heat-polymerized denture base materials: an in vitro study.

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Clinical Oral Investigations Pub Date : 2024-11-06 DOI:10.1007/s00784-024-06016-3
Ozyurt Tekin Selin, Caglar Ipek
{"title":"The effect of various denture cleansers on the physical and mechanical properties of CAD/CAM and heat-polymerized denture base materials: an in vitro study.","authors":"Ozyurt Tekin Selin, Caglar Ipek","doi":"10.1007/s00784-024-06016-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To investigate the effects of denture cleansers on the various properties of CAD/CAM and heat-polymerized polymethyl methacrylate (PMMA).</p><p><strong>Materials and methods: </strong>Two different brands of heat-polymerized and two of milled PMMA were fabricated (n = 50), in total 200. Each group was randomly divided into five subgroups (n = 10): control groups (D1) kept in distilled water, cleaning tablets (D2, D3), neutral (D4) and acidic electrolyzed acid water (EAW) (D5). Surface roughness, hardness and flexural strength values were evaluated. Data were statistically analyzed with two-way ANOVA and Tukey post hoc test for comparison (p<0.05).</p><p><strong>Results: </strong>The milled group showed significantly lower surface roughness, greater surface hardness, and higher flexural strength values than heat polymerized denture bases (p<0.05). The denture cleansers had no significant effect on the surface roughness values of the milled specimens (p>0.05), whereas the specimens in the heat-polymerized groups and treated with D5 showed greater surface roughness values compared with the other cleaning agents (p > 0.05). The denture cleansers had no significant effect on surface hardness and flexural strength of heat polymerize groups (p > 0.05). However, D2, D3 and D5 cleaning agent decreased the hardness values of the milled group (p<0.05) and D5 cleaning agent decreased the flexural strength of the milled group (p<0.05).</p><p><strong>Conclusions: </strong>It was observed that the applied denture cleansers affected the surface roughness, surface hardness, and flexural strength values of both denture bases but within a clinically acceptable value.</p><p><strong>Clinical relevance: </strong>CAD/CAM denture bases showed significantly higher physical and mechanical properties than to heat-polymerized base materials. Although the applied neutral EAW cleaners give desired results for denture bases, clinical studies are needed for biological compatibility.</p>","PeriodicalId":10461,"journal":{"name":"Clinical Oral Investigations","volume":"28 11","pages":"629"},"PeriodicalIF":3.1000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Oral Investigations","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00784-024-06016-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To investigate the effects of denture cleansers on the various properties of CAD/CAM and heat-polymerized polymethyl methacrylate (PMMA).

Materials and methods: Two different brands of heat-polymerized and two of milled PMMA were fabricated (n = 50), in total 200. Each group was randomly divided into five subgroups (n = 10): control groups (D1) kept in distilled water, cleaning tablets (D2, D3), neutral (D4) and acidic electrolyzed acid water (EAW) (D5). Surface roughness, hardness and flexural strength values were evaluated. Data were statistically analyzed with two-way ANOVA and Tukey post hoc test for comparison (p<0.05).

Results: The milled group showed significantly lower surface roughness, greater surface hardness, and higher flexural strength values than heat polymerized denture bases (p<0.05). The denture cleansers had no significant effect on the surface roughness values of the milled specimens (p>0.05), whereas the specimens in the heat-polymerized groups and treated with D5 showed greater surface roughness values compared with the other cleaning agents (p > 0.05). The denture cleansers had no significant effect on surface hardness and flexural strength of heat polymerize groups (p > 0.05). However, D2, D3 and D5 cleaning agent decreased the hardness values of the milled group (p<0.05) and D5 cleaning agent decreased the flexural strength of the milled group (p<0.05).

Conclusions: It was observed that the applied denture cleansers affected the surface roughness, surface hardness, and flexural strength values of both denture bases but within a clinically acceptable value.

Clinical relevance: CAD/CAM denture bases showed significantly higher physical and mechanical properties than to heat-polymerized base materials. Although the applied neutral EAW cleaners give desired results for denture bases, clinical studies are needed for biological compatibility.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
各种义齿清洁剂对 CAD/CAM 和热聚合义齿基托材料的物理和机械性能的影响:体外研究。
目的研究义齿清洁剂对 CAD/CAM 和热聚合聚甲基丙烯酸甲酯(PMMA)各种特性的影响:制作两种不同品牌的热聚合和两种研磨 PMMA(n = 50),共计 200 个。每组随机分为五个子组(n = 10):在蒸馏水中保存的对照组(D1)、清洁片剂组(D2、D3)、中性组(D4)和酸性电解酸水(EAW)组(D5)。对表面粗糙度、硬度和抗折强度值进行了评估。数据采用双向方差分析和 Tukey 后检验进行统计分析(pResults):与热聚合义齿基托相比,研磨组的表面粗糙度明显更低、表面硬度更高、抗弯强度更高(p0.05),而与其他清洁剂相比,热聚合组和用 D5 处理的试样表面粗糙度更高(p > 0.05)。义齿清洁剂对热聚合组的表面硬度和抗弯强度没有明显影响(p > 0.05)。然而,D2、D3 和 D5 清洁剂降低了研磨组的硬度值(p 结论:据观察,使用的义齿清洁剂会影响两种义齿基托的表面粗糙度、表面硬度和抗折强度值,但都在临床可接受的范围内:CAD/CAM义齿基托的物理和机械性能明显高于热聚合基托材料。虽然应用中性 EAW 清洗剂可为义齿基托带来理想的效果,但仍需进行临床研究以确定其生物相容性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Oral Investigations
Clinical Oral Investigations 医学-牙科与口腔外科
CiteScore
6.30
自引率
5.90%
发文量
484
审稿时长
3 months
期刊介绍: The journal Clinical Oral Investigations is a multidisciplinary, international forum for publication of research from all fields of oral medicine. The journal publishes original scientific articles and invited reviews which provide up-to-date results of basic and clinical studies in oral and maxillofacial science and medicine. The aim is to clarify the relevance of new results to modern practice, for an international readership. Coverage includes maxillofacial and oral surgery, prosthetics and restorative dentistry, operative dentistry, endodontics, periodontology, orthodontics, dental materials science, clinical trials, epidemiology, pedodontics, oral implant, preventive dentistiry, oral pathology, oral basic sciences and more.
期刊最新文献
A technical note on the Kamranmeter; a manually operated device for measuring salivary spinnbarkeit. The clinical and microbiological efficacy of a zinc-citrate/hydroxyapatite/potassium-citrate containing toothpaste: a double-blind randomized controlled clinical trial. Fluorescence and color adjustment potentials of paste-type and flowable resin composites in cervical restorations. AI-driven segmentation of the pulp cavity system in mandibular molars on CBCT images using convolutional neural networks. Automatic detection and proximity quantification of inferior alveolar nerve and mandibular third molar on cone-beam computed tomography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1