Carolyn Huffman, Wendy Butcher, Cliff Gonzales, Kerrin Hampton, Lindsay Munn, Ian Saunders, Greg Russell
{"title":"Usability of Light-Linking Technology for Infusion Line Identification: A Simulation Study With ICU Nurses.","authors":"Carolyn Huffman, Wendy Butcher, Cliff Gonzales, Kerrin Hampton, Lindsay Munn, Ian Saunders, Greg Russell","doi":"10.1097/NAN.0000000000000563","DOIUrl":null,"url":null,"abstract":"<p><p>Critical care nurses are faced with increasing task loads due to increasing patient complexity. In addition to this complexity, most critical care patients have a maze of infusion and monitoring lines that must be navigated when administering medications. Task load is escalated when a nurse must identify an injection port and administer a medication rapidly. This study tested a commercially available light-linking infusion line identification device. Researchers compared standard labeling practices to the light-linking technology on time to injection, error rate, usability, and task load. Forty-seven intensive care nurses completed 188 critical care simulations using a randomized cross-over design. Simulations were carried out in both daylight and low-light conditions. The light-linking technology reduced overall time to injection compared to standard labeling practices and demonstrated a significant decrease in time to injection in low-light settings, greater perceived usability, and lower perceived task load. Injection error rate could not be adequately assessed, but 6 of 8 errors were committed in low-light conditions.</p>","PeriodicalId":46291,"journal":{"name":"Journal of Infusion Nursing","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Infusion Nursing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/NAN.0000000000000563","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/30 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0
Abstract
Critical care nurses are faced with increasing task loads due to increasing patient complexity. In addition to this complexity, most critical care patients have a maze of infusion and monitoring lines that must be navigated when administering medications. Task load is escalated when a nurse must identify an injection port and administer a medication rapidly. This study tested a commercially available light-linking infusion line identification device. Researchers compared standard labeling practices to the light-linking technology on time to injection, error rate, usability, and task load. Forty-seven intensive care nurses completed 188 critical care simulations using a randomized cross-over design. Simulations were carried out in both daylight and low-light conditions. The light-linking technology reduced overall time to injection compared to standard labeling practices and demonstrated a significant decrease in time to injection in low-light settings, greater perceived usability, and lower perceived task load. Injection error rate could not be adequately assessed, but 6 of 8 errors were committed in low-light conditions.
期刊介绍:
Journal of Infusion Nursing, the official publication of the Infusion Nurses Society (INS), seeks to promote excellence in infusion nursing by presenting new research, clinical reviews, case studies, and professional development information relevant to the practice of infusion therapy. Articles selected for publication represent the broad scope of the infusion specialty and draw on the expertise of all healthcare providers who participate in the delivery of infusion therapy.