Evaluation of the Anatomical Cross-Sectional Area of Psoas Major Muscle Using an Ultrasound Imaging System Combined With an Inertial Measurement Unit: Improved Reliability in the US Using IMU-Based Positioning Techniques.

IF 1.2 Q3 SPORT SCIENCES Translational sports medicine Pub Date : 2024-10-29 eCollection Date: 2024-01-01 DOI:10.1155/2024/7774612
Kazuhiro Ito, Etsuko Maeshima, Nobuyuki Arai, Koichi Saito, Hiroya Koshiba, Junko Maruyama, Keiji Asada, Takaaki Nakamata, Kazuki Yamaguchi, Yasuhiko Hatanaka
{"title":"Evaluation of the Anatomical Cross-Sectional Area of Psoas Major Muscle Using an Ultrasound Imaging System Combined With an Inertial Measurement Unit: Improved Reliability in the US Using IMU-Based Positioning Techniques.","authors":"Kazuhiro Ito, Etsuko Maeshima, Nobuyuki Arai, Koichi Saito, Hiroya Koshiba, Junko Maruyama, Keiji Asada, Takaaki Nakamata, Kazuki Yamaguchi, Yasuhiko Hatanaka","doi":"10.1155/2024/7774612","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Recently, ultrasound (US) imaging has been used to estimate the cross-sectional area of skeletal muscle, but the reliability is uncertain. To improve the reliability of the US, we investigated skeletal muscle thickness measurement using an inertial measurement unit (IMU) to determine the direction of US beam incidence based on posture angle information. In addition, we examined whether the anatomical cross-sectional area (ACSA) of muscle can be estimated from the muscle thickness measured using the US with the IMU. <b>Methods:</b> In Experiment 1, two examiners measured the right psoas major at the fourth lumbar vertebra level in 10 university students using the US with and without an IMU. The intraclass correlation coefficient (ICC) was used to examine intra- and inter-rater variability. In Experiment 2, the two examiners measured the muscle thickness of the right psoas major in 31 male subjects using the US with an IMU. In addition, the ACSA of this muscle was measured using MRI. Pearson's correlation coefficient was used to examine the relationship between muscle thickness and ACSA, and a single regression analysis was performed. <b>Results:</b> Both intrarater reliability ICC (1, 2) and inter-rater reliability ICC (2, 2) were higher when US was used with IMU compared to without IMU (Experiment 1). A significant positive correlation (<i>r</i> = 0.84, <i>p</i> < 0.01) was observed between muscle thickness and ACSA (Experiment 2). The regression equation was significant at <i>R</i> <sup>2</sup> = 0.71 (<i>p</i> < 0.01). <b>Conclusion:</b> Using an IMU during US measurement of the psoas major improves intra- and interexaminer reliability and can be used to estimate the ACSA of the muscle.</p>","PeriodicalId":75247,"journal":{"name":"Translational sports medicine","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11537743/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Translational sports medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2024/7774612","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SPORT SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Recently, ultrasound (US) imaging has been used to estimate the cross-sectional area of skeletal muscle, but the reliability is uncertain. To improve the reliability of the US, we investigated skeletal muscle thickness measurement using an inertial measurement unit (IMU) to determine the direction of US beam incidence based on posture angle information. In addition, we examined whether the anatomical cross-sectional area (ACSA) of muscle can be estimated from the muscle thickness measured using the US with the IMU. Methods: In Experiment 1, two examiners measured the right psoas major at the fourth lumbar vertebra level in 10 university students using the US with and without an IMU. The intraclass correlation coefficient (ICC) was used to examine intra- and inter-rater variability. In Experiment 2, the two examiners measured the muscle thickness of the right psoas major in 31 male subjects using the US with an IMU. In addition, the ACSA of this muscle was measured using MRI. Pearson's correlation coefficient was used to examine the relationship between muscle thickness and ACSA, and a single regression analysis was performed. Results: Both intrarater reliability ICC (1, 2) and inter-rater reliability ICC (2, 2) were higher when US was used with IMU compared to without IMU (Experiment 1). A significant positive correlation (r = 0.84, p < 0.01) was observed between muscle thickness and ACSA (Experiment 2). The regression equation was significant at R 2 = 0.71 (p < 0.01). Conclusion: Using an IMU during US measurement of the psoas major improves intra- and interexaminer reliability and can be used to estimate the ACSA of the muscle.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用结合惯性测量单元的超声波成像系统评估腰大肌的解剖横截面积:使用基于惯性测量单元的定位技术提高美国的可靠性
简介最近,超声波(US)成像被用于估算骨骼肌的横截面积,但其可靠性并不确定。为了提高 US 的可靠性,我们研究了使用惯性测量单元(IMU)测量骨骼肌厚度的方法,以便根据姿势角度信息确定 US 光束的入射方向。此外,我们还研究了是否可以通过使用 US 和 IMU 测量的肌肉厚度估算出肌肉的解剖横截面积 (ACSA)。实验方法在实验 1 中,两名检查员分别使用带和不带 IMU 的 US 测量了 10 名大学生第四腰椎处的右腰大肌。使用类内相关系数(ICC)检查评分者内部和评分者之间的变异性。在实验 2 中,两位检查员使用带有 IMU 的 US 测量了 31 名男性受试者的右腰大肌厚度。此外,还使用核磁共振成像测量了这块肌肉的 ACSA。使用皮尔逊相关系数检验肌肉厚度和 ACSA 之间的关系,并进行单一回归分析。结果显示与不使用 IMU 的情况相比,在使用 US 和 IMU 时,评分者内部可靠性 ICC (1, 2) 和评分者之间可靠性 ICC (2, 2) 都更高(实验 1)。在肌肉厚度和 ACSA 之间观察到明显的正相关(r = 0.84,p < 0.01)(实验 2)。回归方程为 R 2 = 0.71(p < 0.01)。结论:在对腰大肌进行 US 测量时使用 IMU 可提高检查者内部和检查者之间的可靠性,并可用于估算肌肉的 ACSA。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
3.00
自引率
0.00%
发文量
0
期刊最新文献
Evaluation of the Anatomical Cross-Sectional Area of Psoas Major Muscle Using an Ultrasound Imaging System Combined With an Inertial Measurement Unit: Improved Reliability in the US Using IMU-Based Positioning Techniques. Effect of 1-Week Weight Loss While Maintaining Total Body Water on Jump Performance. Lower Extremity Asymmetry Values Derived From Multiple Strength Testing Modes Are Associated With Perceived Functional Capabilities Among University Athletes. Athlete Monitoring Systems in Elite Men's Basketball: Challenges, Recommendations, and Future Perspectives. An Injury Prevention Programme in Physical Education Teacher Education Students: Process Evaluation Using the RE-AIM Sports Setting Matrix.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1