{"title":"Use of ST/HR hysteresis decreases false positive rate in exercise electrocardiography test of middle-aged asymptomatic women","authors":"","doi":"10.1016/j.jelectrocard.2024.153820","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><div>Exercise electrocardiography (ECG) is a common diagnostic and prognostic method for the detection of coronary artery disease (CAD). However, its accuracy in asymptomatic women has not been comprehensively investigated and the diagnostic criteria may require refinements. This study evaluated the performance of ECG-derived ST/HR-index, ST/HR hysteresis and ST-segment depression parameters among asymptomatic middle-aged women.</div></div><div><h3>Methods</h3><div>108 women (mean age 56 ± 4 years) performed exercise ECG test on treadmill until exhaustion three times within a nine-month period. False-positive rates of maximum ST/HR-index, ST/HR hysteresis, and ST-segment depression values measured from 12 leads at peak exercise and after one-minute recovery were evaluated with recommended diagnostic partition values. Repeatability was assessed with intraclass correlation (ICC) and Bland-Altman plot analysis.</div></div><div><h3>Results</h3><div>False-positive rate was lower for all variables when a two‑lead configuration was used instead of a single‑lead configuration. Using a two‑lead configuration, ST/HR hysteresis (0–1.9 %) and ST-segment depression after one-minute recovery (0–2.8 %) had lower false-positive rates compared to ST/HR index (3.7–20.4 %) and ST-segment depression at peak exercise (9.3–27.8 %). ICC values indicated moderate repeatability for ST/HR hysteresis while ST/HR index, ST-segment at peak exercise, and ST-segment after one-minute recovery had moderate-to-good repeatability. Bland-Altman analysis indicated poor repeatability for all evaluated ECG variables.</div></div><div><h3>Conclusion</h3><div>In asymptomatic middle-aged women, practitioners should prefer the use of ST/HR hysteresis and ST-segment after one-minute recovery over the conventional ST-segment depression at peak exercise or ST/HR index, and evaluate the ECG data from a two‑lead configuration instead of single‑lead.</div></div>","PeriodicalId":15606,"journal":{"name":"Journal of electrocardiology","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of electrocardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0022073624002905","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Exercise electrocardiography (ECG) is a common diagnostic and prognostic method for the detection of coronary artery disease (CAD). However, its accuracy in asymptomatic women has not been comprehensively investigated and the diagnostic criteria may require refinements. This study evaluated the performance of ECG-derived ST/HR-index, ST/HR hysteresis and ST-segment depression parameters among asymptomatic middle-aged women.

Methods

108 women (mean age 56 ± 4 years) performed exercise ECG test on treadmill until exhaustion three times within a nine-month period. False-positive rates of maximum ST/HR-index, ST/HR hysteresis, and ST-segment depression values measured from 12 leads at peak exercise and after one-minute recovery were evaluated with recommended diagnostic partition values. Repeatability was assessed with intraclass correlation (ICC) and Bland-Altman plot analysis.

Results

False-positive rate was lower for all variables when a two‑lead configuration was used instead of a single‑lead configuration. Using a two‑lead configuration, ST/HR hysteresis (0–1.9 %) and ST-segment depression after one-minute recovery (0–2.8 %) had lower false-positive rates compared to ST/HR index (3.7–20.4 %) and ST-segment depression at peak exercise (9.3–27.8 %). ICC values indicated moderate repeatability for ST/HR hysteresis while ST/HR index, ST-segment at peak exercise, and ST-segment after one-minute recovery had moderate-to-good repeatability. Bland-Altman analysis indicated poor repeatability for all evaluated ECG variables.

Conclusion

In asymptomatic middle-aged women, practitioners should prefer the use of ST/HR hysteresis and ST-segment after one-minute recovery over the conventional ST-segment depression at peak exercise or ST/HR index, and evaluate the ECG data from a two‑lead configuration instead of single‑lead.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用 ST/HR 滞后可降低无症状中年女性运动心电图测试的假阳性率。
背景:运动心电图(ECG)是检测冠状动脉疾病(CAD)的常用诊断和预后方法。然而,该方法在无症状女性中的准确性尚未得到全面研究,诊断标准可能需要改进。本研究评估了无症状中年女性心电图ST/HR指数、ST/HR滞后和ST段压低参数的性能。方法:108名女性(平均年龄56±4岁)在9个月内三次在跑步机上进行运动心电图测试,直至力竭。用推荐的诊断分区值评估了运动高峰时和一分钟恢复后从 12 个导联测量的最大 ST/HR 指数、ST/HR 滞后和 ST 段压低值的假阳性率。通过类内相关性(ICC)和Bland-Altman图分析评估了重复性:结果:使用双导联配置而非单导联配置时,所有变量的假阳性率均较低。使用双导联配置时,ST/HR 滞后(0-1.9%)和一分钟恢复后的 ST 段压低(0-2.8%)的假阳性率低于 ST/HR 指数(3.7-20.4%)和运动高峰时的 ST 段压低(9.3-27.8%)。ICC值表明ST/HR滞后的重复性为中等,而ST/HR指数、运动高峰时的ST段和一分钟恢复后的ST段的重复性为中等至良好。Bland-Altman分析表明,所有评估的心电图变量的重复性都较差:结论:对于无症状的中年女性,医生应优先使用 ST/HR 滞后和一分钟恢复后的 ST 段,而不是传统的运动高峰期 ST 段压低或 ST/HR 指数,并从双导联配置而不是单导联评估心电图数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of electrocardiology
Journal of electrocardiology 医学-心血管系统
CiteScore
2.70
自引率
7.70%
发文量
152
审稿时长
38 days
期刊介绍: The Journal of Electrocardiology is devoted exclusively to clinical and experimental studies of the electrical activities of the heart. It seeks to contribute significantly to the accuracy of diagnosis and prognosis and the effective treatment, prevention, or delay of heart disease. Editorial contents include electrocardiography, vectorcardiography, arrhythmias, membrane action potential, cardiac pacing, monitoring defibrillation, instrumentation, drug effects, and computer applications.
期刊最新文献
Nonparoxysmal junctional tachycardia associated with 3:2 Wenckebach exit block in the absence of digitalis therapy Study on the feasibility of distinguishing ventricular and pre-excited arrhythmia rhythms by a new algorithm The ECG of a 6-year-old girl Use of ST/HR hysteresis decreases false positive rate in exercise electrocardiography test of middle-aged asymptomatic women Detailed association between adolescent obesity and ventricular repolarization.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1