Diagnostic accuracy of TB screening tests in a prospective multinational cohort: Chest-X-ray with computer-aided detection, Xpert TB host response, and C-reactive protein

IF 8.2 1区 医学 Q1 IMMUNOLOGY Clinical Infectious Diseases Pub Date : 2024-11-07 DOI:10.1093/cid/ciae549
Rebecca Crowder, Balamugesh Thangakunam, Alfred Andama, Devasahayam J Christopher, Victoria Dalay, Welile Nwamba, Sandra V Kik, Dong Van Nguyen, Nguyen Viet Nhung, Patrick P J Phillips, Morten Ruhwald, Grant Theron, William Worodria, Charles Yu, Payam Nahid, Adithya Cattamanchi, Ankur Gupta-Wright, Claudia M Denkinger
{"title":"Diagnostic accuracy of TB screening tests in a prospective multinational cohort: Chest-X-ray with computer-aided detection, Xpert TB host response, and C-reactive protein","authors":"Rebecca Crowder, Balamugesh Thangakunam, Alfred Andama, Devasahayam J Christopher, Victoria Dalay, Welile Nwamba, Sandra V Kik, Dong Van Nguyen, Nguyen Viet Nhung, Patrick P J Phillips, Morten Ruhwald, Grant Theron, William Worodria, Charles Yu, Payam Nahid, Adithya Cattamanchi, Ankur Gupta-Wright, Claudia M Denkinger","doi":"10.1093/cid/ciae549","DOIUrl":null,"url":null,"abstract":"Background Accessible, accurate screening tests are necessary to advance tuberculosis (TB) case finding and early detection in high-burden countries. Methods We prospectively screened adults with ≥2 weeks of cough at primary health centers in the Philippines, Vietnam, South Africa, Uganda, and India. Participants received chest-X-ray, Cepheid Xpert TB Host Response (Xpert HR) testing, and point-of-care C-reactive protein (CRP) testing (Boditech). Chest-X-ray images were processed using CAD4TB v7, a computer-aided detection algorithm. We assessed diagnostic accuracy against a microbiologic reference standard (sputum Xpert Ultra, culture). Optimal cut-points were chosen to maximize specificity at 90% sensitivity. Two-test screening algorithms were considered, using 1) sequential negative serial screening (positive defined as positive on either test) and 2) sequential positive serial screening (positive defined as positive on both tests). Results Between July 2021 and August 2022, 1,392 participants with presumptive TB had valid index tests and reference standard results, and 303 (22%) had confirmed TB. In head-to-head comparisons, CAD4TB v7 showed the highest specificity at 90% sensitivity (70.3% vs. 65.1% for Xpert HR, difference 95% CI 1.6 to 8.9; 49.7% for CRP, difference 95% CI 17.0 to 24.3). Three two-test screening algorithms met WHO target product profile (TPP) minimum accuracy thresholds and had higher accuracy than any test alone. At 90% sensitivity, the specificity was 79.6% for Xpert HR-CAD4TB [sequential negative], 75.9% for CRP-CAD4TB [sequential negative], and 73.7% for Xpert HR-CAD4TB [sequential positive]. Conclusions CAD4TB achieves TPP targets and outperforms Xpert HR and CRP. Combining screening tests further increased accuracy. Registration NCT04923958","PeriodicalId":10463,"journal":{"name":"Clinical Infectious Diseases","volume":"9 1","pages":""},"PeriodicalIF":8.2000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Infectious Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/cid/ciae549","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background Accessible, accurate screening tests are necessary to advance tuberculosis (TB) case finding and early detection in high-burden countries. Methods We prospectively screened adults with ≥2 weeks of cough at primary health centers in the Philippines, Vietnam, South Africa, Uganda, and India. Participants received chest-X-ray, Cepheid Xpert TB Host Response (Xpert HR) testing, and point-of-care C-reactive protein (CRP) testing (Boditech). Chest-X-ray images were processed using CAD4TB v7, a computer-aided detection algorithm. We assessed diagnostic accuracy against a microbiologic reference standard (sputum Xpert Ultra, culture). Optimal cut-points were chosen to maximize specificity at 90% sensitivity. Two-test screening algorithms were considered, using 1) sequential negative serial screening (positive defined as positive on either test) and 2) sequential positive serial screening (positive defined as positive on both tests). Results Between July 2021 and August 2022, 1,392 participants with presumptive TB had valid index tests and reference standard results, and 303 (22%) had confirmed TB. In head-to-head comparisons, CAD4TB v7 showed the highest specificity at 90% sensitivity (70.3% vs. 65.1% for Xpert HR, difference 95% CI 1.6 to 8.9; 49.7% for CRP, difference 95% CI 17.0 to 24.3). Three two-test screening algorithms met WHO target product profile (TPP) minimum accuracy thresholds and had higher accuracy than any test alone. At 90% sensitivity, the specificity was 79.6% for Xpert HR-CAD4TB [sequential negative], 75.9% for CRP-CAD4TB [sequential negative], and 73.7% for Xpert HR-CAD4TB [sequential positive]. Conclusions CAD4TB achieves TPP targets and outperforms Xpert HR and CRP. Combining screening tests further increased accuracy. Registration NCT04923958
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
前瞻性多国队列中结核病筛查试验的诊断准确性:计算机辅助检测的胸部 X 光、Xpert TB 宿主反应和 C 反应蛋白
背景 在结核病负担沉重的国家,要推进结核病(TB)病例发现和早期检测工作,就必须进行方便、准确的筛查试验。方法 我们在菲律宾、越南、南非、乌干达和印度的初级保健中心对咳嗽≥2 周的成年人进行了前瞻性筛查。参与者接受了胸部 X 光检查、Cepheid Xpert TB 宿主反应(Xpert HR)检测和床旁 C 反应蛋白(CRP)检测(Boditech)。胸部 X 光图像使用计算机辅助检测算法 CAD4TB v7 进行处理。我们对照微生物学参考标准(痰培养 Xpert Ultra)评估了诊断准确性。我们选择了最佳切点,以便在灵敏度为 90% 的情况下最大限度地提高特异性。考虑了两种检测筛查算法:1)连续阴性序列筛查(阳性定义为任一检测结果均为阳性);2)连续阳性序列筛查(阳性定义为两种检测结果均为阳性)。结果 在 2021 年 7 月至 2022 年 8 月期间,有 1392 名推定肺结核患者接受了有效的指标检测和参考标准结果,其中 303 人(22%)确诊为肺结核。在正面比较中,CAD4TB v7 的灵敏度为 90%,特异性最高(Xpert HR 为 70.3%,CRP 为 49.7%,95% CI 为 17.0 至 24.3)。三种双测试筛查算法达到了世卫组织目标产品规格(TPP)的最低准确度阈值,其准确度高于单独使用任何一种测试的准确度。在灵敏度为 90% 的情况下,Xpert HR-CAD4TB [连续阴性] 的特异性为 79.6%,CRP-CAD4TB [连续阴性] 的特异性为 75.9%,Xpert HR-CAD4TB [连续阳性] 的特异性为 73.7%。结论 CAD4TB 可达到 TPP 目标,且优于 Xpert HR 和 CRP。结合筛查检验可进一步提高准确性。注册 NCT04923958
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Clinical Infectious Diseases
Clinical Infectious Diseases 医学-传染病学
CiteScore
25.00
自引率
2.50%
发文量
900
审稿时长
3 months
期刊介绍: Clinical Infectious Diseases (CID) is dedicated to publishing original research, reviews, guidelines, and perspectives with the potential to reshape clinical practice, providing clinicians with valuable insights for patient care. CID comprehensively addresses the clinical presentation, diagnosis, treatment, and prevention of a wide spectrum of infectious diseases. The journal places a high priority on the assessment of current and innovative treatments, microbiology, immunology, and policies, ensuring relevance to patient care in its commitment to advancing the field of infectious diseases.
期刊最新文献
Rapid HCV Engagement and Treatment in Hospitalized Patients. Association between use of a voluntary isolation centre and reduced household SARS-CoV-2 transmission: A matched cohort study from Toronto, Canada Closing the gap in race-based inequities for seasonal influenza hospitalizations: a modeling study. Predicting risk of tuberculosis disease in people migrating to a low-TB incidence country: development and validation of a multivariable dynamic risk prediction model using health administrative data Tuberculosis Preventive Treatment for Pregnant People With Human Immunodeficiency Virus in South Africa: A Modeling Analysis of Clinical Benefits and Risks.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1