Ahmed S Beela, Claudia A Manetti, Frits W Prinzen, Tammo Delhaas, Lieven Herbots, Joost Lumens
{"title":"The mechanistic interaction between mechanical dyssynchrony and filling pressure in cardiac resynchronization therapy candidates.","authors":"Ahmed S Beela, Claudia A Manetti, Frits W Prinzen, Tammo Delhaas, Lieven Herbots, Joost Lumens","doi":"10.1093/ehjci/jeae286","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Both left ventricular (LV) mechanical dyssynchrony and filling pressure have been shown to be associated with outcome in heart failure patient treated with cardiac resynchronization therapy (CRT).</p><p><strong>Objectives: </strong>To investigate the mechanistic link between mechanical dyssynchrony and filling pressure and to assess their combined prognostic value in CRT candidates.</p><p><strong>Methods: </strong>Left atrial pressure (LAP) estimation and quantification of mechanical dyssynchrony were retrospectively performed in 219 CRT patients using echocardiography. LAP was elevated (eLAP) in 49% of the population, normal (nLAP) in 40%, and indeterminate (iLAP) in 11%. CRT response was defined as %-decrease in LV end-systolic volume after 12±6 months CRT. Clinical endpoint was all-cause mortality during 4.8 years (interquartile range: 2.7-6.0 years). To investigate the mechanistic link between mechanical dyssynchrony and filling pressure, the CircAdapt computer model was used to simulate cardiac mechanics and hemodynamics in virtual hearts with LBBB and various causes of increased filling pressure.</p><p><strong>Results: </strong>Patients with nLAP had more significant mechanical dyssynchrony than those with eLAP. The combined assessment of both parameters before CRT was significantly associated with reverse LV remodeling and post-CRT survival. Simulations revealed that mechanical dyssynchrony is attenuated by increased LV operational chamber stiffness, regardless of whether it is caused by passive or active factors, explaining the link between mechanical dyssynchrony and filling pressure.</p><p><strong>Conclusion: </strong>Our combined clinical-computational data demonstrate that in patients with LBBB, the presence of mechanical dyssynchrony indicates relatively normal LV compliance and low filling pressure, which may explain their strong association with positive outcomes after CRT.</p>","PeriodicalId":12026,"journal":{"name":"European Heart Journal - Cardiovascular Imaging","volume":" ","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Heart Journal - Cardiovascular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ehjci/jeae286","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Both left ventricular (LV) mechanical dyssynchrony and filling pressure have been shown to be associated with outcome in heart failure patient treated with cardiac resynchronization therapy (CRT).
Objectives: To investigate the mechanistic link between mechanical dyssynchrony and filling pressure and to assess their combined prognostic value in CRT candidates.
Methods: Left atrial pressure (LAP) estimation and quantification of mechanical dyssynchrony were retrospectively performed in 219 CRT patients using echocardiography. LAP was elevated (eLAP) in 49% of the population, normal (nLAP) in 40%, and indeterminate (iLAP) in 11%. CRT response was defined as %-decrease in LV end-systolic volume after 12±6 months CRT. Clinical endpoint was all-cause mortality during 4.8 years (interquartile range: 2.7-6.0 years). To investigate the mechanistic link between mechanical dyssynchrony and filling pressure, the CircAdapt computer model was used to simulate cardiac mechanics and hemodynamics in virtual hearts with LBBB and various causes of increased filling pressure.
Results: Patients with nLAP had more significant mechanical dyssynchrony than those with eLAP. The combined assessment of both parameters before CRT was significantly associated with reverse LV remodeling and post-CRT survival. Simulations revealed that mechanical dyssynchrony is attenuated by increased LV operational chamber stiffness, regardless of whether it is caused by passive or active factors, explaining the link between mechanical dyssynchrony and filling pressure.
Conclusion: Our combined clinical-computational data demonstrate that in patients with LBBB, the presence of mechanical dyssynchrony indicates relatively normal LV compliance and low filling pressure, which may explain their strong association with positive outcomes after CRT.
期刊介绍:
European Heart Journal – Cardiovascular Imaging is a monthly international peer reviewed journal dealing with Cardiovascular Imaging. It is an official publication of the European Association of Cardiovascular Imaging, a branch of the European Society of Cardiology.
The journal aims to publish the highest quality material, both scientific and clinical from all areas of cardiovascular imaging including echocardiography, magnetic resonance, computed tomography, nuclear and invasive imaging. A range of article types will be considered, including original research, reviews, editorials, image focus, letters and recommendation papers from relevant groups of the European Society of Cardiology. In addition it provides a forum for the exchange of information on all aspects of cardiovascular imaging.