Sensitivity and Costs of Intraoperative Trans-Impedance Matrix Recordings, Spread of Excitation Functions, and X-ray Imaging in Detecting Cochlear Implant Tip Foldovers.

IF 1.9 3区 医学 Q3 CLINICAL NEUROLOGY Otology & Neurotology Pub Date : 2024-12-01 DOI:10.1097/MAO.0000000000004361
Viral Tejani, Robin Piper, Gail Murray, Nauman F Manzoor, Sarah Mowry, Maroun Semaan, Alejandro Rivas
{"title":"Sensitivity and Costs of Intraoperative Trans-Impedance Matrix Recordings, Spread of Excitation Functions, and X-ray Imaging in Detecting Cochlear Implant Tip Foldovers.","authors":"Viral Tejani, Robin Piper, Gail Murray, Nauman F Manzoor, Sarah Mowry, Maroun Semaan, Alejandro Rivas","doi":"10.1097/MAO.0000000000004361","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Evaluate the sensitivity and financial costs of Trans-Impedance Matrix recordings, Spread of Excitation functions, and x-rays in detecting cochlear implant tip foldovers.</p><p><strong>Setting: </strong>Tertiary academic medical center.</p><p><strong>Patients: </strong>113 ears of 108 patients.</p><p><strong>Interventions: </strong>Following cochlear implantation and before concluding surgery, intraoperative Trans-Impedance Matrix recordings, Spread of Excitation functions, and x-rays were conducted to evaluate presence of tip foldover.</p><p><strong>Main outcome measures: </strong>Presence of tip foldover; recording time necessary for and costs of Trans-Impedance Matrix, spread of excitation, and x-rays.</p><p><strong>Results: </strong>There were six tip foldovers. Trans-Impedance Matrix showed 100% sensitivity, 100% specificity, 100% positive predictive value, and 100% negative predicative value in detecting tip foldovers. Spread of excitation showed 29% sensitivity, 99% specificity, 67% positive predictive value, and 95% negative predicative value. Trans-Impedance Matrix recordings were completed significantly faster than spread of excitation and x-rays. Elimination of x-rays from our intraoperative workflow results in a twofold cost reduction.</p><p><strong>Conclusion: </strong>Trans-Impedance Matrix recordings have potential great clinical utility in evaluating proper CI placement intraoperatively and reducing costs of surgery while not compromising patient care. Given the low tip foldover rate, a multicenter study is in progress to evaluate the sensitivity, specificity, positive predictive value, and negative predicative value of Trans-Impedance Matrix in a larger dataset. This can provide better guidance to cochlear implant clinics interested in evaluating the impact of using Trans-Impedance Matrix on patient care as well as the economics of reducing use of intraoperative imaging.</p>","PeriodicalId":19732,"journal":{"name":"Otology & Neurotology","volume":"45 10","pages":"e763-e771"},"PeriodicalIF":1.9000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Otology & Neurotology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MAO.0000000000004361","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Evaluate the sensitivity and financial costs of Trans-Impedance Matrix recordings, Spread of Excitation functions, and x-rays in detecting cochlear implant tip foldovers.

Setting: Tertiary academic medical center.

Patients: 113 ears of 108 patients.

Interventions: Following cochlear implantation and before concluding surgery, intraoperative Trans-Impedance Matrix recordings, Spread of Excitation functions, and x-rays were conducted to evaluate presence of tip foldover.

Main outcome measures: Presence of tip foldover; recording time necessary for and costs of Trans-Impedance Matrix, spread of excitation, and x-rays.

Results: There were six tip foldovers. Trans-Impedance Matrix showed 100% sensitivity, 100% specificity, 100% positive predictive value, and 100% negative predicative value in detecting tip foldovers. Spread of excitation showed 29% sensitivity, 99% specificity, 67% positive predictive value, and 95% negative predicative value. Trans-Impedance Matrix recordings were completed significantly faster than spread of excitation and x-rays. Elimination of x-rays from our intraoperative workflow results in a twofold cost reduction.

Conclusion: Trans-Impedance Matrix recordings have potential great clinical utility in evaluating proper CI placement intraoperatively and reducing costs of surgery while not compromising patient care. Given the low tip foldover rate, a multicenter study is in progress to evaluate the sensitivity, specificity, positive predictive value, and negative predicative value of Trans-Impedance Matrix in a larger dataset. This can provide better guidance to cochlear implant clinics interested in evaluating the impact of using Trans-Impedance Matrix on patient care as well as the economics of reducing use of intraoperative imaging.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
术中跨阻抗矩阵记录、激发函数展宽和 X 射线成像在检测人工耳蜗尖端折叠方面的灵敏度和成本。
目标: 评估跨阻抗矩阵记录、激励扩散函数和 X 射线在检测人工耳蜗尖端折叠方面的灵敏度和经济成本:评估跨阻抗矩阵(Trans-Impedance Matrix)记录、激励扩散(Spread of Excitation)功能和X射线在检测人工耳蜗尖端折叠方面的灵敏度和经济成本:环境:三级学术医疗中心:108名患者的113只耳朵:干预措施:在人工耳蜗植入术后和手术结束前,进行术中跨阻抗矩阵记录、激励扩散函数和 X 光检查,以评估是否存在耳尖折叠:主要结果指标:是否存在针尖折叠;记录跨阻抗矩阵、激励扩散和 X 射线所需的时间和成本:结果:共发生六次针尖折叠。在检测尖端折叠方面,跨阻抗矩阵显示出 100% 的灵敏度、100% 的特异性、100% 的阳性预测值和 100% 的阴性预测值。激励扩散的灵敏度为 29%,特异性为 99%,阳性预测值为 67%,阴性预测值为 95%。跨阻抗矩阵记录的完成速度明显快于激发扩散和 X 射线。在我们的术中工作流程中取消 X 射线可使成本降低两倍:跨阻抗矩阵记录在术中评估 CI 的正确放置和降低手术成本方面具有潜在的巨大临床用途,同时不会影响患者护理。鉴于尖端折叠率较低,目前正在进行一项多中心研究,以评估跨阻抗矩阵在更大数据集中的灵敏度、特异性、阳性预测值和阴性预测值。这将为有兴趣评估使用跨阻抗矩阵对患者护理的影响以及减少术中成像使用的经济性的人工耳蜗植入诊所提供更好的指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Otology & Neurotology
Otology & Neurotology 医学-耳鼻喉科学
CiteScore
3.80
自引率
14.30%
发文量
509
审稿时长
3-6 weeks
期刊介绍: ​​​​​Otology & Neurotology publishes original articles relating to both clinical and basic science aspects of otology, neurotology, and cranial base surgery. As the foremost journal in its field, it has become the favored place for publishing the best of new science relating to the human ear and its diseases. The broadly international character of its contributing authors, editorial board, and readership provides the Journal its decidedly global perspective.
期刊最新文献
Audiologic Outcomes After Cochlear Implantation in Prelingually Deaf Children Who Have Combined Anomalies or Disabilities. Book Review: Forensic Audiology-A Guide for the Expert Witness, Robert M. Traynor and Krista B. Traynor, Plural Publishing, San Diego, 2024. Analgesia After Vestibular Schwannoma Surgery in Europe-Potential for Reduction of Postoperative Opioid Usage. Cochlear Implantation With Sporadic Inner Ear Schwannomas: Outcomes in 106 Patients From an International Multi-Institutional Study. GLP-1 Receptor Agonist Induced Eustachian Tube Dysfunction: Database and Systematic Review of Otolaryngologic Adverse Events.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1