Assessment of Microcirculatory Dysfunction by Measuring Subcutaneous Tissue Oxygen Saturation Using Near-Infrared Spectroscopy in Patients with Circulatory Failure.
{"title":"Assessment of Microcirculatory Dysfunction by Measuring Subcutaneous Tissue Oxygen Saturation Using Near-Infrared Spectroscopy in Patients with Circulatory Failure.","authors":"Jun Sato, Atsushi Sakurai, Shingo Ihara, Katsuhiro Nakagawa, Nobutaka Chiba, Takeshi Saito, Kosaku Kinoshita","doi":"10.3390/diagnostics14212428","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Patients with circulatory failure have high mortality rates and require prompt assessment of microcirculation. Despite the improvement in hemodynamic parameters, microcirculatory dysfunction persists. We measured subcutaneous regional tissue oxygen saturation (rSO<sub>2</sub>) with near-infrared spectroscopy (NIRS), which can assess microcirculation in patients with circulatory failure.</p><p><strong>Methods: </strong>A finger-worn oximeter with NIRS measured rSO<sub>2</sub> in the forehead, thenar eminence, thumb, and knees. First, the rSO<sub>2</sub> was measured in healthy adult volunteers (<i>n</i> = 10). Circulatory failure was defined as a systolic blood pressure ≤ 90 mmHg and lactate ≥ 2 mmol/L. The study included 35 patients without circulatory failure and SOFA score of 0 at ICU admission and 38 patients with circulatory failure at ICU admission. Both groups included a single-center prospective study of patients who were transported to the ICU of the Nihon University Hospital. The rSO<sub>2</sub> was measured only on ICU admission in the non-circulatory failure group and later in the circulatory failure group.</p><p><strong>Results: </strong>In the volunteer group, rSO<sub>2</sub> at each site was approximately 58%. The rSO<sub>2</sub> was significantly lower in the circulatory failure group than in the non-circulatory failure group (knee, <i>p</i> < 0.01). In the circulatory failure group, knee rSO<sub>2</sub> showed a significant negative correlation with SOFA score (Day 0, ρ = -0.37, <i>p</i> = 0.02; Day 1, ρ = -0.53, <i>p</i> < 0.01; Day 2, ρ = -0.60, <i>p</i> < 0.01).</p><p><strong>Conclusions: </strong>Subcutaneous knee rSO<sub>2</sub> was associated with SOFA score and was considered an indicator of microcirculatory dysfunction and organ damage.</p>","PeriodicalId":11225,"journal":{"name":"Diagnostics","volume":"14 21","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-10-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11545383/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3390/diagnostics14212428","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Patients with circulatory failure have high mortality rates and require prompt assessment of microcirculation. Despite the improvement in hemodynamic parameters, microcirculatory dysfunction persists. We measured subcutaneous regional tissue oxygen saturation (rSO2) with near-infrared spectroscopy (NIRS), which can assess microcirculation in patients with circulatory failure.
Methods: A finger-worn oximeter with NIRS measured rSO2 in the forehead, thenar eminence, thumb, and knees. First, the rSO2 was measured in healthy adult volunteers (n = 10). Circulatory failure was defined as a systolic blood pressure ≤ 90 mmHg and lactate ≥ 2 mmol/L. The study included 35 patients without circulatory failure and SOFA score of 0 at ICU admission and 38 patients with circulatory failure at ICU admission. Both groups included a single-center prospective study of patients who were transported to the ICU of the Nihon University Hospital. The rSO2 was measured only on ICU admission in the non-circulatory failure group and later in the circulatory failure group.
Results: In the volunteer group, rSO2 at each site was approximately 58%. The rSO2 was significantly lower in the circulatory failure group than in the non-circulatory failure group (knee, p < 0.01). In the circulatory failure group, knee rSO2 showed a significant negative correlation with SOFA score (Day 0, ρ = -0.37, p = 0.02; Day 1, ρ = -0.53, p < 0.01; Day 2, ρ = -0.60, p < 0.01).
Conclusions: Subcutaneous knee rSO2 was associated with SOFA score and was considered an indicator of microcirculatory dysfunction and organ damage.
DiagnosticsBiochemistry, Genetics and Molecular Biology-Clinical Biochemistry
CiteScore
4.70
自引率
8.30%
发文量
2699
审稿时长
19.64 days
期刊介绍:
Diagnostics (ISSN 2075-4418) is an international scholarly open access journal on medical diagnostics. It publishes original research articles, reviews, communications and short notes on the research and development of medical diagnostics. There is no restriction on the length of the papers. Our aim is to encourage scientists to publish their experimental and theoretical research in as much detail as possible. Full experimental and/or methodological details must be provided for research articles.