Utilization of a hierarchical electrocardiogram classification model for enhanced biometric identification

IF 7 2区 医学 Q1 BIOLOGY Computers in biology and medicine Pub Date : 2024-11-08 DOI:10.1016/j.compbiomed.2024.109254
YeJin Kim, Chang Choi
{"title":"Utilization of a hierarchical electrocardiogram classification model for enhanced biometric identification","authors":"YeJin Kim,&nbsp;Chang Choi","doi":"10.1016/j.compbiomed.2024.109254","DOIUrl":null,"url":null,"abstract":"<div><div>Emerging research on artificial intelligence (AI) has leveraged the unique properties of electrocardiogram (ECG) signals for user identification. ECG signals, known for their resistance to forgery and tampering, offer security advantages. However, these signals fluctuate in response to physical and cognitive stress. Despite their security benefits, these dynamic characteristics present challenges for consistent user identification owing to their variable amplitudes and shapes. To address these problems, we propose a 2-stage user identification system that integrates ECG signals and status information. This system classifies the user’s ECG status and uses the feature values in a second model to improve dynamic feature learning ability. This allows identification with high accuracy even in various stress states of the user. This increases the real-life usability of the ECG user identification system. The effectiveness of the proposed method was confirmed through a performance evaluation using CSU-BIODB(Chosun University-BIO Database) and the public MIT-BIH(Massachusetts Institute of Technology - Beth Israel Hospital Arrhythmia Laboratory) ST Change database, with identification accuracies of 92.08% and 95.83%, and f1-scores of 0.9207 and 0.9369, respectively. Compared with existing single user identification models, our approach demonstrated accuracy improvements of 9.3% and 36.76% for each database. These findings underscore the potential of the new 2-stage model for enhancing the practicality of ECG-based user identification systems and provide a promising foundation for future research on deep learning signal processing.</div></div>","PeriodicalId":10578,"journal":{"name":"Computers in biology and medicine","volume":"184 ","pages":"Article 109254"},"PeriodicalIF":7.0000,"publicationDate":"2024-11-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers in biology and medicine","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0010482524013398","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Emerging research on artificial intelligence (AI) has leveraged the unique properties of electrocardiogram (ECG) signals for user identification. ECG signals, known for their resistance to forgery and tampering, offer security advantages. However, these signals fluctuate in response to physical and cognitive stress. Despite their security benefits, these dynamic characteristics present challenges for consistent user identification owing to their variable amplitudes and shapes. To address these problems, we propose a 2-stage user identification system that integrates ECG signals and status information. This system classifies the user’s ECG status and uses the feature values in a second model to improve dynamic feature learning ability. This allows identification with high accuracy even in various stress states of the user. This increases the real-life usability of the ECG user identification system. The effectiveness of the proposed method was confirmed through a performance evaluation using CSU-BIODB(Chosun University-BIO Database) and the public MIT-BIH(Massachusetts Institute of Technology - Beth Israel Hospital Arrhythmia Laboratory) ST Change database, with identification accuracies of 92.08% and 95.83%, and f1-scores of 0.9207 and 0.9369, respectively. Compared with existing single user identification models, our approach demonstrated accuracy improvements of 9.3% and 36.76% for each database. These findings underscore the potential of the new 2-stage model for enhancing the practicality of ECG-based user identification systems and provide a promising foundation for future research on deep learning signal processing.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用分层心电图分类模型增强生物识别能力。
新兴的人工智能(AI)研究利用心电图(ECG)信号的独特特性进行用户识别。心电信号以不易伪造和篡改而著称,具有安全优势。然而,这些信号会随着身体和认知压力而波动。尽管这些信号具有安全优势,但由于其振幅和形状可变,这些动态特征给一致的用户识别带来了挑战。为解决这些问题,我们提出了一种整合心电信号和状态信息的两阶段用户识别系统。该系统对用户的心电图状态进行分类,并在第二个模型中使用特征值来提高动态特征学习能力。这样,即使在用户的各种压力状态下,也能进行高精度的识别。这提高了心电图用户识别系统在现实生活中的可用性。通过使用 CSU-BIODB(朝鲜大学-BIO 数据库)和公开的 MIT-BIH(麻省理工学院-贝斯以色列医院心律失常实验室)ST 变化数据库进行性能评估,证实了所提方法的有效性,识别准确率分别为 92.08% 和 95.83%,f1 分数分别为 0.9207 和 0.9369。与现有的单一用户识别模型相比,我们的方法在每个数据库中的准确率分别提高了 9.3% 和 36.76%。这些发现凸显了新的两阶段模型在提高基于心电图的用户识别系统实用性方面的潜力,并为未来的深度学习信号处理研究奠定了良好的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Computers in biology and medicine
Computers in biology and medicine 工程技术-工程:生物医学
CiteScore
11.70
自引率
10.40%
发文量
1086
审稿时长
74 days
期刊介绍: Computers in Biology and Medicine is an international forum for sharing groundbreaking advancements in the use of computers in bioscience and medicine. This journal serves as a medium for communicating essential research, instruction, ideas, and information regarding the rapidly evolving field of computer applications in these domains. By encouraging the exchange of knowledge, we aim to facilitate progress and innovation in the utilization of computers in biology and medicine.
期刊最新文献
An adaptive enhanced human memory algorithm for multi-level image segmentation for pathological lung cancer images. Integrating multimodal learning for improved vital health parameter estimation. Riemannian manifold-based geometric clustering of continuous glucose monitoring to improve personalized diabetes management. Transformative artificial intelligence in gastric cancer: Advancements in diagnostic techniques. Artificial intelligence and deep learning algorithms for epigenetic sequence analysis: A review for epigeneticists and AI experts.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1