{"title":"Complex left atrial appendage closure using 3D printing system simulation in a patient with mitral prosthetic valve: a case report.","authors":"Luca Vicini Scajola, Antonio Sanzo, Giulia Magrini, Stefania Marconi, Roberto Rordorf","doi":"10.1093/ehjcr/ytae574","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Left atrial appendage (LAA) closure (LAAc) has emerged as a safe and effective alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF) and contraindications to OAC.</p><p><strong>Case summary: </strong>A 61-year-old woman with permanent AF and a history of mitral surgery replacement with mechanical prosthesis was referred to our cardiology department to undergo LAAc. The preoperative computed tomography (CT) revealed that the ostium of the LAA was close to the mitral prosthesis ring. As a result of the difficult LAA morphology, a CT image-based virtual model was created, then a 3D printing model was prepared in our laboratory, and procedure simulation was performed with the two different LAA occlusion devices (plug- vs. pacifier-like models) to see which one was more suitable for the patient anatomy.</p><p><strong>Discussion: </strong>In this case of complex LAAc in a patient with mechanical prosthetic mitral valve, the use of a 3D printed model has guided prosthesis selection and device sizing reducing procedure time and complications.</p>","PeriodicalId":11910,"journal":{"name":"European Heart Journal: Case Reports","volume":"8 11","pages":"ytae574"},"PeriodicalIF":0.8000,"publicationDate":"2024-10-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11561574/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Heart Journal: Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjcr/ytae574","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Left atrial appendage (LAA) closure (LAAc) has emerged as a safe and effective alternative to oral anticoagulation (OAC) for stroke prevention in patients with atrial fibrillation (AF) and contraindications to OAC.

Case summary: A 61-year-old woman with permanent AF and a history of mitral surgery replacement with mechanical prosthesis was referred to our cardiology department to undergo LAAc. The preoperative computed tomography (CT) revealed that the ostium of the LAA was close to the mitral prosthesis ring. As a result of the difficult LAA morphology, a CT image-based virtual model was created, then a 3D printing model was prepared in our laboratory, and procedure simulation was performed with the two different LAA occlusion devices (plug- vs. pacifier-like models) to see which one was more suitable for the patient anatomy.

Discussion: In this case of complex LAAc in a patient with mechanical prosthetic mitral valve, the use of a 3D printed model has guided prosthesis selection and device sizing reducing procedure time and complications.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
利用 3D 打印系统模拟二尖瓣人工瓣膜患者的复杂左房阑尾闭合:病例报告。
背景:病例摘要:一位61岁的女性患者患有永久性房颤,并有二尖瓣手术置换机械假体的病史,她被转诊至我院心内科接受LAAc手术。术前计算机断层扫描(CT)显示,LAA 的出口靠近二尖瓣假体环。由于 LAA 形态复杂,我们创建了一个基于 CT 图像的虚拟模型,然后在本实验室制作了一个 3D 打印模型,并使用两种不同的 LAA 闭塞装置(塞子式与奶嘴式模型)进行了手术模拟,以确定哪种装置更适合患者的解剖结构:讨论:在这例使用机械人工二尖瓣的复杂 LAAc 患者中,三维打印模型的使用指导了人工瓣膜的选择和装置的尺寸,减少了手术时间和并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Heart Journal: Case Reports
European Heart Journal: Case Reports Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.30
自引率
10.00%
发文量
451
审稿时长
14 weeks
期刊最新文献
A case report supporting early surgery in mitral valve infective endocarditis with recurrent cerebral infarcts. Mechanical circulatory support for high-risk surgical aortic valve and ascending aortic replacement in severe bicuspid aortic valve stenosis: a case series. Dual transcatheter edge-to-edge repair in a patient with cardiac amyloidosis and severe secondary mitral and tricuspid regurgitation: a case report. Successful implantation of cardiac resynchronization therapy in a patient with coronary sinus reducer using proximal coronary sinus branches: a case report. Successful transcatheter edge-to-edge repair for tricuspid regurgitation in a patient with a double-inlet left ventricle and discordant connections of the great arteries: a case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1